JUN 03 198j e

Docket Nos.

50-259, 50-260 L 50-296 License Nos.

DPR"33, DPR-55 8

DPR-68 EA 81-30 Tennessee Valley Authority ATTN:

M.

F. Millis General Manager 500A Chestnut Street Tower II Chattanooga, TN 3740l g) u, ~OS ~981~

co~lsg~y~

Pjy Gentlemen:

This refers to your letter of April 3, 1981, in response to the Notice of Violation and Proposed Imposition of Civil Penalties and Notice of Deviation sent to you with our letter of March 20, 1981 concerning enforcement matters identified during the January 6-9 and 20-23, 1981 inspection of the Browns Ferry Plant by the NRC Region II Office.

Your prompt response to our letter of March 20 and the proposed corrective action indicates that TVA is making a concerted effort to correct deficiencies'n the fire protection program.

However, after careful consideration of your

response, we have concluded that, with the exception of Item C, the violations occurred as stated in the Notice of Violation and Proposed Imposition of Civil Penalties.

Me have also concluded for the reasons stated in Enclosure 2 that the deviations occurred as stated in the Notice of Deviation.

Therefore, civil penalties proposed in the Notice of Violation and Proposed Imposition of Civil Penalties should be imposed with the following exception.

After consideration of your response to Item C, the NRC has withdrawn the violation and its proposed civil penalty.

The results of future inspections, including implementation of corrective actions described in your April 3 letter, will be considered in determining whether further enforcement action is appropriate.

0 CERTIFIED MAIL RETURN RECEIPT RE UESTED

~g~/2 gg 9

'I h

'h I

Tennessee Valley Authority

- 2 "

A copy of this letter and the enclosure will be placed in the NRC's Public Document Room in accordance with Section 2.790 of the NRC's "Rules of Practice,"

Part.2, Title 10, Code of Federal Regulations.

Sincerhly,

) S)~>(1e~ ~i Victor Stello, Jr., Director Office of Inspection and Enforcement Encl osures:

l.

Order Imposing Civil Monetary Penalties with Appendix 2.

Evaluation and Conclusion with respect to deviations cc w/encl:

H.

G. Parris, Manager of Power H. J.

Green, Division Director H.

L. Abercrombie, Plant Superintendent R.

E.

Rogers, Project Engineer H.

N. Culver, Chief, Nuclear Safety Review Staff Distribution PDR NSIC TIC LPDR ACRS SECY ZA

APuglise, CON L-316 VStello, IE
RDeYoung, IE
JSniezek, IE DThompson TBrockett, IE
GBarber, IE
JMurray, ELD

, JLieberman, ELD

FIngram, PA
JCrooks, MPA JJCummings, AEOD Enforcement Coordinators RI, RII, RIII, V,

RV WPU:JD

IE THOM12(f)

GBar er 5/28/81 5/2 /81 IE Files Central Files CP Book EI Reading File

<DO Iteading File TAIppolito, NRR

~RJClark, NRR Public Service Commission ATTN:

Juanita W. McDaniel President State Office Bldg Montgomery, AL 36104 FAWN ~

gg (Cov)av) 51&(<j Office of the Attorney General ATTN:

Hon. Charles Graddick Attorney General State Administrative Bldg.

Montgomery, AL 36130

/81 5/f)/81

/81

~/81 State Dept, of Public Health ATTN:

Aubrey Godwin, Director

~

Division of Radiological Health State Office Bldg.

Montgomery, AL 36104

I

'I i

ll