05000260/LER-1980-047-04, /04T-0:on 801107,component Cooling Water Pumps Found Not Operating,Thus Not Providing Adequate Dilution of Water to Environ.Caused by Component Cooling Water Pumps Being Out of Svc.Plant Instructions Revised

From kanterella
(Redirected from ML18025B202)
Jump to navigation Jump to search
/04T-0:on 801107,component Cooling Water Pumps Found Not Operating,Thus Not Providing Adequate Dilution of Water to Environ.Caused by Component Cooling Water Pumps Being Out of Svc.Plant Instructions Revised
ML18025B202
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 11/20/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18025B201 List:
References
LER-80-047-04T, LER-80-47-4T, NUDOCS 8011250384
Download: ML18025B202 (4)


LER-1980-047, /04T-0:on 801107,component Cooling Water Pumps Found Not Operating,Thus Not Providing Adequate Dilution of Water to Environ.Caused by Component Cooling Water Pumps Being Out of Svc.Plant Instructions Revised
Event date:
Report date:
2601980047R04 - NRC Website

text

(7 77) v Eo ooso4'EL)'gss

'\\.

p'7 LlCENSEE EVENT REPORT

~ol

'7 8

CON'T

~o 7

8 (PLEASE PRINT OR TYPE ALLREQUIRED INFORMATION) 0 0QE 4

1 1

1 I OE~OL 25 26 LICENSE TYPE30 57 CAT 58

.2 0

0 OB CONTROL BLOCK:

6 A

L B

R F

2 Q20 0

0 0

0 0

0 9

LICENSEE CODE 14

'15 LICENSE NUMBER PE sPURcE ~LQ6 0

5 0

0 0

2 6

60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE 80 EVENT DESCRIPTION AND PROBABLE CONSEQUENCES Q10 Durin refuelin'uta e while chlorinatin unit 2 it was realized that CCM um s

~03 were not in operation providing ade uate dilution of water to the environment.

('~

~06

~O7 Chlorination be an at 1625 hours0.0188 days <br />0.451 hours <br />0.00269 weeks <br />6.183125e-4 months <br /> 11 d 11-7-80.

Maximum chlorination level measured in the raw coolin water was

.49 m.

Reference E T S

2 2 of ublic.

No revious occurrences.

~os 7

8 9

SYSTEM

CAUSE

CAUSE Coh'IP.

VALVE CODE CODE SUBCODE COMPONENT CODE SUBCODE SUBCODE

~OB i~~Q"

~DQI2

~ZOI3 Z

Z Z

Z Z

Z Q4

~ZQIB

~ZGB 7

8 9

10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION LER/RQ FVENT YEAR REPORT NO.

CODE TYPE NO.

017 IIEP0117 LILLJLI ~

LJLLP~

~~

~4

~f

~0 21 22 23 24 26 27 28 29 30 31 32 ACTION FUTURE EFFECT SHUTDOWN ATTACHMENT NPRD 4 PRIME COIPIP.

COMPONENY TAKEN ACTION ON PLANT METHOD HOURS Q22 SUBMITTED FORM SUB.

SUPPLIER hIANUFhCTUREI'QE~QE

~ZQEE

~ZQEI 0

0 0

0

~YQEE

~NOTE

~ZQs Z

9 9

9 I

33 34 35 36 37 40 41 42 43 44

.'I CAUSE DESCRIPTION AND CORRECTIVE ACTIONS Q27 o

CCW um s were not in service which resulted in little dilution of raw coolin water to the environment.

Chlorination was immediatel sto ed u o d

c METHOD OF OTHER STATUS ~

DISCOVERY DISCOVERY DESCRIPTION Q32 NA

~AQ3l 0 erator observed.

44 45 46 44 NA NRC USE ONLY Plant instructions will be revised to include verification that the CCW um s 3

are operating prior to beginning chlorination.

4 7

8 9

FACILITY STATUS 99 POWE R 4

lJLIQEE ~oo 0

Qoo 7

8 9

10 I'2 13 ACTIVITY CONTENT RELEASED OF RELEASE AMOUNTOF ACTIVITYQ LOCATIONOF REI.EASE Q36 EK LZJ Q33 IZJQ34 NA 7

8 9

10 11 45 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION Q3B CZ LoaoJO>>l z lOE NA 7

8 9

11 12 13 PERSONNEL INJURIES NUMBER DESCRIPTION Q41

~~gJQO 7

8 9

11 12 LOSS OF OR DAMAGETO FACILITYQ43 TYPE

DESCRIPTION

~IB

~Q42 NA 7

8 9

10 PUBLICITY ISSUED

~

DESCRIPTIONQ

~044 JJJJJJJO 7

8 0

10 801 18593@)'

PHONE:

6 I

p ~,

Tennessee Valley Authority Browns Ferry Nuclear Plant LER SUPPLEMENTAL INFORMATION Form BF-.1V BF 15.2 1/10/V9 BFRO 260 /~~~

Technical Specification Involved E,T.S. 2.'2.2 Reported Under Technical Specification 6 3 b

  • ~

f 0 Identification and Descri tion of Occurrence:

While chlorinating unit 2, it was realised that the CCW pumps were not in operation providing adequate dilution of water to the environment.

Ch3.orination began at 1625 hours0.0188 days <br />0.451 hours <br />0.00269 weeks <br />6.183125e-4 months <br />, 11-6-80, and was terminated at 1120 hours0.013 days <br />0.311 hours <br />0.00185 weeks <br />4.2616e-4 months <br />, 11-7-80.

Maximum chlorination level measure'd in the raw cooling water was

.49 ppm.

Compliance with the residual chlorine limit of 0.05 MG/L can not be confirmed for unit 2 CCW discharge.

Conditions Prior to Occurrence:

Unit 1 8

98%

Unit 2 8

0%

refueling outage Unit 3 6

89%

Action sp'ecified in the Technical Specification Surveillance Requirements met due to ino erable e ui ment.

Describe.

Samples were taken from RCW system.

A arent Cause of Occurrence:-

J CCW pumps were not in service which resulted in little dilution of raw cooling water to'he environment.

Anal sis of Occurrence:

P

. There was no damage to plant equipment.

There was no actin.ty release',

no personnel exposure or in)ury and no danger to the health or safety of the public.

Corrective Action

Chlorination was immediat'ely stopped upon discovery of CCW pumps not in operation.

Plant instructions will be revised to include. verification that the CCW pumps are operating.priof to beginning chlorination.

Failure Data:

NA Retention:

  • Revision:

eriod - Lifetime; Responsibility - Administrative Supervisor

I