05000260/LER-1980-021-03, /03L-0:on 800506,during Routine Shutdown, Particulate Channel 2-RR-90-249 Was Erratic & Declared Inoperable.Caused by Failure of Recorder Amplifier.Amplifier Replaced.Failure Attributed to Normal Aging

From kanterella
(Redirected from ML18025A910)
Jump to navigation Jump to search
/03L-0:on 800506,during Routine Shutdown, Particulate Channel 2-RR-90-249 Was Erratic & Declared Inoperable.Caused by Failure of Recorder Amplifier.Amplifier Replaced.Failure Attributed to Normal Aging
ML18025A910
Person / Time
Site: Browns Ferry 
Issue date: 06/04/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML18025A909 List:
References
LER-80-021-03L-02, LER-80-21-3L-2, NUDOCS 8006110156
Download: ML18025A910 (4)


LER-1980-021, /03L-0:on 800506,during Routine Shutdown, Particulate Channel 2-RR-90-249 Was Erratic & Declared Inoperable.Caused by Failure of Recorder Amplifier.Amplifier Replaced.Failure Attributed to Normal Aging
Event date:
Report date:
2601980021R03 - NRC Website

text

NHL t Uflr'>>I j>>JI>>

{7 77)

~.

~

~ n II~

Ai>>

>>'4 CONTROL BLOCK:

I

~OI A

L B

R F

7 8

9 LICENSEE CODE U S. tJUCLEAR REGULATOfzv (ZF>>>>P>>>>tt>>ISIOt>>

LlQGPJQINQ KLt(114 f f3c()flQT Ol IPLEASE PRINT OR TYF>>B rhLL REQUIRED INFORMATIONI 2

Q>>

0 0

0 0

0 0

0

0 0

Q>>4 I

I I LQ4~Q>>

14 I5 LICENSE NUMBER 25 26 LICENSE TYPE 30 -'7 CAT SB CON'T I Llfg 0 5

0 0

0 2

6 0

7 0

5 0

6 8

0 8

0 6

0 4

8 0

QB SOURCE 7

8 60 6'I DOCKET NUMBER f>>8 69 EVENT DATE 74 ls REPORT DATE 80 EVENT OFSCRIPTION ANO PROBABLE CONSEQUENCES QIO OON

~o3 dec 1ared inoperab 1 e.

Recorder was out of service 23 hours2.662037e-4 days <br />0.00639 hours <br />3.80291e-5 weeks <br />8.7515e-6 months <br /> contrary to T. S.

3 ~ 8 ~ B. 8 ~

J

~o4 Temporary monitoring by Chemica 1 Lab was performed during this period.

There was I ~os no danger to hea 1th or saf ety of publie.

No previous occurrences

~OG

~08 7

8 9

L>>,>>

7 8

SYSTEM

causE

cAUSE Coh>>f'.

VaLvE CODE COOC SUBCODE C(i IPDNENT CODE SUBCODE SUBCODE

~O

~NC Q>>>>,E 6>>

~FQ>>3 2

N 8

T R

0 Q>>

LJpi>>

~Z Qln 9

10 11 12 13 18 19, 20 SEQUENTIAL OCCURRENCE REPORT REVISION LF A AO EVENT YEAR AFPOflT NO.

.CODE I YPG NQ Q>>

n>>"4"r ~80

+

~02 I

+H I~03

+L

+

+0 21 22 23 24 2G 2I 28 29 30 31 32 acl lotr fulu<<E EF rEc 7 s<<ufoovrN ATTACHMENT NPAD 4 PRIh'IE COMP.

COMPONENT TAKE'N ACTION ON PLANT h>>ETIIQD

<<QU<<s

+22 suBMITTED Fo<<hl SUB.

suPPLIEH h'IANvFAGTUflEfr

~AQ~>> ~ZQ~>>

~zn

~zp>>>>

0 0

0 Yr

~YQ>>>>

~NP>>>>

~LQ>>>>

L 1

3 0 I(

33 34

'b 3G 37 40 41 42 43 44 4/

CAUSE DESCRIPTION ANO CORRECTIVE ACTIONS 27 2-RR-90-249 was erratic due to a failed recorder amplifier.

Amplifier was replaced,

'functionally tested and returned to service.

Leeds-Northrup, recorder amplifier, Hodel 101174.

No recurrence control required.

Failure attributed to normal aging.

3 4

8 9fAGILITY 7

STATUS "4 POVJER OTIIEASTATUS Q

~l5 o

p>>>> ~oo o g29, NA 7

8 9

10 12 ll 44 ACTIVITY CONTENT AfLE'AS>>FD OF <<EL EAsf:

AMOUNTOf: ACTIVITYQB Z

Q>>>>

~ZQ>>>> [

NA 7

8 9

'IO 44 PEflSONNEL FXPOSUAES truMBEA TYPE OESCAIP fION 39 LOOO OOgP>>, ~ZP NA-7 8

9 11 12 13 Pf ASONtJEL INJuflICS METIIOO OF DISCQVEf1Y DISCOVERY OESCAIPTIOIJ Q32

~A'31 Operator observed.

45 46 LOCATIONOF RELEASE QG NA 46 8>>I 80 B>>l f0 7

8 7

8 9

'IO PIJBL ICI 1 Y 9

11 12 LOSS OF OA DAMAGE TO FACII.ITY 43 1 YPC l)ESCAIPTION z

Q>>r NA NRC USE ONLY

>> BI)

B>>f 7

8 9

If) nnM>> or. nnri nnrn

~0(p3~

g-F) g -

68 G9 8('>>

I

,=',, Tennessee Valley Author Browns Ferry Nuclear Plant f>>tan 8 F-5 V BF 15. 2 1/10/79 LER SUP PLEMENTAL INFORMATION BFRO-So-260 / 802l Technical Specification Involved 3.8.8.8 Reported Under Technical Specification 6.7.2.b(2)

Date of Occurrence 5/6/80 Time of Occurrence Unit Identification and Descri tiorr of Occurrence:

Particulate channel recorder 2-RR-90-249 was erratic and declared inoperable.

The recorder was out-of-service for 23 hours2.662037e-4 days <br />0.00639 hours <br />3.80291e-5 weeks <br />8.7515e-6 months <br />.

Conditions Prior to Occurrence:

Unit l '8 0%

Unit 2 8 98%

Unit 3 8 99%

Action specified in the Technical Specification 'Surveillance Requirements met I

p Chemical lab performed temporary monitoring.

Apparent Cause of Occurrence:

Recorder became erratic due to a failed recorder amplifier.

Analysis of Occurr ence:

There was no damage to plant equipment.

There was no activity release, no personnel exposure or injury and'no danger to the health or safety of the public.

Corrective Action

The recorder amplifier was replaced, to service.

functionally tested and recorder returned Failure Data:

~Retention:

. eriod - Lifetime; Responsibility - Administrative Supervisor

~Revision:

0 0