'ocket Nos. 50-259/260/296 JAN 18 ]ggg SSINS No.:
6020 Tennessee Valley Authority
~
ATTN:
Mr. H.
G. Parris Manager of Power 500A Chestnut Street Tower II Chattanooga, TN 37401
, Gentlemen:
We have received your letter of January 10, 1980, with your check for $29,000.
Your response to our Order and the items of noncompliance contained in our January 4, 1980 letter will be discussed at a management meeting at the Athens, Alabama City Hall on January 21, 1980.
We support your effort to review the Browns Ferry Technical Specifications to resolve the concerns as described in the second item of your January 10, 1980 letter.
The staff of the Region II Office will contact you about this matter and will arrange for the necessary NRC assistance.
We appreciate your cooperation with us.
Sincerely, ictor tello, Jr.
Director Office of Inspection and Enforcement SEE PREVIOUS YELLOW FOR CONCURRED(Qp WPU/DLM/SM Office ROI: I ROI [%
1/18/80 Surname Stone yan Jab P
Date 1/)//8 1/<R/80 Pgi045 ROQ~
A: XOOS: XE
%fosse]~
Gower 1//X/80 1/
/80 A:DD:IE D
Thompson S
1 1/
/80 1 i /80