BFN-17 Table 12.3-1 PLANT RADIATION ZONE CLASSIFICATIONS Shielding Access Access Design Dose Rate Action Requirements Zone Conditions Occupancy Dose Rate Range to Enter Zone 1

Unlimited Continuous

<1.0 mRem/hr 2a Regulated Continuous 1.0 mRem/hr 2b Regulated Periodic 15 mRem/hr 3

Controlled Unoccupied 50-1,000 mRem/hr 4

Prohibited Unoccupied

>1,000 mRem/hr Access Dose Rate Range will meet 10 CFR 20 requirements as given in plant procedures.