REQU ORY INFORMATION DISTR IBUT BYBTEl'I
<R IDS>
ACCESSION NBR: 8606100472 DOC. DATE: 86/06/04 NOTARIZED:
NO DOCKET FACIL: 50-400 Shear on Harris Nuclear Power PlantR Unit ii Carolina 05000400 AUTH. MANE AUTHOR AFFILIATION NOLAN>J. P.
Affiliation Not Assigned RECIP. NAME RECIPIENT AFFILIATION DENTONp H.
Office of -Nuclear Reactor Regulation>
Director (post 851125
SUBJECT:
Opposes util exemption from requirement of full participation emergency plan test within 1
Mr prior to QL issuance.
DISTRIBUTION CODE:
YEOSD COPIES RECEIVED: LTR l ENCL Q.
SIZE:
TITLE: Request for NRR Action
<e. g.
- 2. 206 Petitions) fc Related Correspondenc NOTES: Application for permit renewal filed.
05000400 RECIP IENT ID CODE/NAt'tE PWR-A PD2 LA 3UCKLEY B 01 COPIES LTTR E 1
CL RECIPIENT ID CODE/MANE PWR-A PD2 PD COPIES LTTR ENCL INTERNAL: EDO/ACB ELD/RED REC FILE EXTERNAL: 24X NRC PDR 04 02 EL@AH 1
RW D
LPDR NBIC 03 05 TOTAL NUMBER OF COPIEB REQUIRED:
LTTR 12 ENCL
Mr. Harold Denton Director, Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.
20555
( 301 ) 492-7000
Subject:
Shearon Harris nuclear plant, Carolina Power
& Eight, Emergency Plan
Dear Mr. Denton,
Carolina Power
& Light Company has not conducted a full participation test of the present emergency plan for the Shearon Harris nuclear plant as required by federal regulation, 10 CFR Part 50.
This is most significant since Chatham
- County, by formal action of the Board of Commissioners, has withdrawn from the emergency plan.
- Thus, no plan which could actually be implemented if the plant were to operate has been tested.
In addition, citizens and officials in other counties are considering withdrawing from the present emergency plan.
- Clearly, any such action would further complicate this matter.
At least until such time as state and local governmental participation in an emergency plan for Shearon Harris is fully resolved, no exemption(s) from the requirement of a
full participation test within one year prior to the granting of any full power license should be considered or approved.
Sincerely,
- 9. Ido'l~
C~gQ $i('o~ P~
~QQg C4 (~< Hh) Alp
~80AM)Q~ 8bOb04 PDR ADOCK 05000400 H