ML18018A901

From kanterella
Jump to navigation Jump to search
Forwarding GE Report Entitled, Analytical Model for Liquid Jet Properties for Predicting Forces on Rigid Submerged Structures, NED0-21472
ML18018A901
Person / Time
Site: Nine Mile Point 
Issue date: 05/02/1978
From: Sobon L
General Electric Co
To: Stolz J
Office of Nuclear Reactor Regulation
References
MFN-187-78
Download: ML18018A901 (6)


Text

STANDARD DXSTRXBUTION FOR NRC FORM 196 (2 7S) 1 ING MATERIAL RELATING TO i'ONTAINMENT UMNUC~eR REGULATORY CQMMISSION NRC DISTRlBUTION FQR PART 50 DOCKET MATERlAL 6%i8f5$%%

TOPICAL REPORT TO:

Mr. John F, Stolz FROM:

General Electric San Jose, Ca.

95125 DATE QF OQCUMENT 05 02 78 OATS RECEIVED 0

MieTTER

~QRIQINAI.

QCCP Y QNQTQRIZED ZfUNCLASSIP IED PROP INPUT FQRM NUMBER QF COPIES RECEIVED

/6/J 640 OESCRIPTION 2p ENCI QSURE Forwarding G.ED rept entitled:

" Analytical Model For Liquid Jet Properties For Predicting Forces On Rigid Submerged Structures,"

NED0-21472, dtd Sept 1977 '

~

26p jcm 05/15/78 ~

FOR ACTION/INFORMATION LETTERS OF INCORPORATXON WILL BE'LACED M EACH DOCKET LISTED BELOWe.

NOTE CYS. WILL BE,PLACED IN. THE LPDR FOR'HE.

FOLLOWING:

ZIHHER 50&58 iiE HILE'

'0 4lO LIHERXCK 50-352/353 WPPS 2.50-39T BAILS'0-367 SHOREHAH.$0 3W LA SALLE'0-373/374 gp/oau a,~

CENTRAL FI ~S 2

W IiRC PDR R~S 7

'S ot iISIC 4CRS 6

Ie SIHWELL 2

Ge LAMIAS 7

Je ~GHT C

ANDERSON Ie PELTIER E~CKNN LYNCH Je SiiELL Ae

BCURNLl, We KAiIE S ~ HLER 0

b.

AVl INTERNALDISTRIBUTION LETTER ONLY Re DEYOUNG Ke RIEL Oe PARR Re. TEDESCO He RUSHBROOK We PZK Se VARGA 7i ET%

h)l&L mlem ue EXTERNAL DISTR IBUTION CONTROL NUMBER 731-20044

0 E N E RA L I E L ~~/ Pflt8f+IIILMP@~R ENERGY

-L, GENERAL ELECTRIC COMPANY, 175 CURTNER AVE., SAN JOSE, CALIFORNIA95125 MC 681, (408) 925-3495 PROJECTS DIVISION MFN-187-78 Nay 2, 1978 U.S. Nuclear Regulatory Commission Division of Reactor Licensing Office of Nuclear Reactor Regulation Washington, D.

C.

20555 Attention:

Mr. John F. Stolz, Chief Light Water Reactors B~anch No.

1 w7 Pl c:>.~

lg K

C CD~

A-CQ C)

Gentlemen:

SUBJECT'eference:

GENERAL ELECTRIC REPORT, "ANALYTICALMODEL FOR LIQUID JET PROPERTIES FOR PREDICTING FORCES ON RIGID SUBMERGED

(

STRUCTURES,"

NED0-21472, DATED SEPTEMBER 1977 Letter with Report, "General Electric Report,

'Analytical Model for Liquid Jet Properties for Predicting Forces on Rigid Submerged Structures,'EDE-21472, dated September 1977," to J.

F. Stolz (NRC) from L. J.

Sobon (GE), dated January 26, 1978 One hundred (100) copies of the subject report (NEDO-21472) are being provided by General Electric for the Nark I and Mark II Owners Groups-for your review as part of the respective Containment

Programs, Tasks 5.14 and A.5.

This report, which is the non-proprietary version of NEDE-21472, provided to you earlier this year (reference) provides a method for calculating LOCA and Ramshead water-jet loads on submerged structures.

A Vtl It

GENERAL "g ELECTRIC Mr.

John F. Stol z Page 2

May 2, 1978 Any questions regarding this report should be directed to L. H. Frauenholz, the Mark II Containment Licensing Engineer, (408) 925-2623.

Sincerely,

/=

L. J.

Sobon, Manager "

BMR Containment Licensing Containment Improvement Programs LJS:mh/1649-1650

Enclosures:

100 cc:

C. J.

Anderson (NRC)

H.

C.

Brinkmann (Mark II Owners Group)

L.

S. Gifford (GE, Bethesda)

J.

C. Guibert (NRC)

I. A. Peltier (NRC)

R. L. Tedesco (NRC)

File:

3.2.7