Text
ASMECodeCaseN780 StephenCumblidge NRC/IndustryNDETechnical InformationExchangeMeeting January1618,2018
ASMECodeN780
- N780allowsanessentialvariables,typically equipment,tobechangedinanAppendixVIII qualifiedprocedure
- ThegoalofN780istoprovideflexibilityin upgradingequipment
- TheNRChasconcernsthatuntested equipmentcouldbeusedininspections, reducingtheeffectivenessofAppendixVIII requirements 2
ProposedRG1.193Revision5
- Atthistime,theNRCwillreviewapplicationofCode CaseN780onacasebycasebasis.TheCodeCaseisa newalternativetothecurrentrequirementsinSection XI,AppendixVIII.Thetechnicaljustificationforthe alternativeisbasedlargelyontheexpertiseof nondestructiveexaminationexpertsandlaboratory testing.Whilethelaboratorytestingwaswell conducted,itwasnotbounding.TheNRCbelievesthat industryexperienceinapplyingthealternativeis neededtoensuregenericapplicabilityand demonstratereliabilitybeforethealternativecanbe approvedinRG1.147.
3
N780andAppendixVIII
- AppendixVIIIParagraph3130EssentialVariable Rangesrequiresablindpersonnel demonstrationtesttoalteranessentialvariable
- AppendixVIII4000providestolerancesinsome essentialvariables
- Supplement1providesrulesforevaluatingthe electroniccharacteristicsofultrasonicsystems
- N780requiresatechnicaljustificationanda practicaldemonstration,withthePDAevaluating both 4
PathForwardforN780
- TheNRCisnotopposedtotheconcept,butwe haveconcernsabouthowN780couldbeapplied
- ExamplesoftheN780processwouldbevery usefulindemonstratinghowthecodecasewould beusedtoupdateequipment
- TheNRCwouldtakeanyadditionaltechnical justificationforN780intoaccountinthenext roundofrulemakingforRG1.147andRG1.193 5