ACCELERATOR DOCUIVIENTDISTRSUTION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

I ACCESSION NBR:9301040144 DOC.DATE: 92/12/22 NOTARIZED: NO FACIL:50-400 Shearon Harris Nuclear Power Plant, Unit 1, Carolina AUTH.NAME AUTHOR AFFILIATION MCCARTHY,D.C.

Carolina Power 6 Light Co.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Submits info re NRC Bulletin 88-11, "Pressurizer Surge Line Thermal Stratification."

CPSL modified design of supports during refueling outage RFP 4,which completed actions re bulletin.

DISTRIBUTION CODE:

IE30D COPIES.RECEIVED:LTR C ENCL L

SIZE:

TITLE: Bulletin 88-11 Pressurizer Surge Line Thermal Stratification DOCKET 05000400 NOTES:Application for permit renewal filed.

05000400 RECIPIENT ID CODE/NAME PD2-1 LA LE,N INTERNAL: AEOD/DOA NRR CHANiT.

NRR/DET/EMEB 7E NRR/DOEA/OGCB11 R/BS-8E2 G~

02 RGN2 FILE 01 COPIES LTTR ENCL RECIPIENT ID CODE/NAME PD2-1 PD AEOD/ROAB NRR SHAW,H.

NRR/DOEA/OEAB11 NRR/DREP/PEPB9D NRR/PMAS/ILRB12 RES/DSIR/EIB COPIES LTTR ENCL EXTERNAL: NRC PDR NSIC NOTE TO ALL"RIDS" RECIPIENTS PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM PI-37 (EXT. 504-2065) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 18 ENCL

CML Carolina Power 8 Light Company DEC P,3 1992 SERIAL:

NLS-92-329 United States Nuclear Regulatory Commission ATTENTION:

Document Control Desk Washington, DC 20555 SHEARON HARRIS NUCLEAR POWER PLANT DOCKET NO. 50-400/LICENSE NO. NPF-63 NRC Bulletin 88-11, "PRESSURIZER SURGE LINE THERMAL STRATIFICATION"

Reference:

CP&L Letter NLS-91-103 dated April 30, 1991 from G.

E. Vaughn (CP&L) to NRC Document Control Desk Gentlemen:

On December 20,

1988, the NRC issued Bulletin 88-11 which requested addressees to establish and implement a program to confirm pressurizer surge line integrity.

Licensees were requested to demonstrate that the pressurizer surge line meets applicable design codes and other FSAR and regulatory commitments for the licensed life of the plant, considering the phenomena of thermal stratification and thermal striping in the fatigue and stress evaluations.

By letter dated April 30,

1991, CP&L notified the NRC that the reanalysis of the She"ron Harris Nuclear Power Plant (SHNPP) surge line had been corp'ted and that the pressurizer surge line piping met applicable Code requirements for the design life of the plant including maximum allowable component stress and cumulative usage factors.

The analysis also showed that two of the surge line rigid supports may experience loads in excess of the Code allowable

'values when the effects of thermal stratification and striping are taken into account concurrently with other design loadings.

As a result, CP&L modified the design of these supports during the recently completed refueling outage (RFO Number 4).

Modification of these supports completed CP&L's actions associated with NRC Bulletin 88-11.

Questions regarding this matter may be referred to Mr. R.

W. Prunty at (919) 546-7318.

Yo s very truly, DCM/SDC cc:

Mr. S.

D. Ebneter Mr. N. B. Le Mr. J.

E. Tedrow D.

C. McCarthy Manager Nuclear Licensing Section 9301040i44 921222 PDR ADOCK 05000400 8

PDR

~ayettevitte Street

~ P. O. Box 1551

~ Rateign, M, C, 27602