ML18010A821

From kanterella
Jump to navigation Jump to search
Forwards LER 91-008-02.Rev Discusses Addl Testing Performed on High Head SI Sys During Current Refueling Outage & Mod to Sys Which Will Prevent Recurrence of Event
Date released: 08/31/2018 Download: ML18010A821


LER 91-008-02:on 910403,testing Determined That High Head SI Sys in Degraded Condition Resulting in Relief Valve Seat Leakage & Drain Line Weld Failure.Caused by Inadequate Design.Supports Added to Lines.Also Reported Per Part 21
ML18010A822
Person / Time
Site: Harris 
Issue date: 10/13/1992
From: Hamby M
CAROLINA POWER & LIGHT CO.
To:
References
REF-PT21-92
Download: ML18010A822 (8)
Forwards LER 91-008-02.Rev Discusses Addl Testing Performed on High Head SI Sys During Current Refueling Outage & Mod to Sys Which Will Prevent Recurrence of Event
ML18010A820
Person / Time
Site: Harris 
Issue date: 10/13/1992
From: Hinnant C
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
REF-PT21-92
Download: ML18010A820 (2)