Forwards LER 91-008-02.Rev Discusses Addl Testing Performed on High Head SI Sys During Current Refueling Outage & Mod to Sys Which Will Prevent Recurrence of Event
Date released: 08/31/2018 Download: ML18010A821


LER 91-008-02:on 910403,testing Determined That High Head SI Sys in Degraded Condition Resulting in Relief Valve Seat Leakage & Drain Line Weld Failure.Caused by Inadequate Design.Supports Added to Lines.Also Reported Per Part 21