Forwards Insp Rept 50-400/91-15 on 910603-07.Violations Identified to Be Discussed at Enforcement Conference Scheduled for 910703
ML18009A946
Person / Time
Site: Harris 
Issue date: 06/12/1991
From: Reyes L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Eury L
CAROLINA POWER & LIGHT CO.
Shared Package
ML18009A947 List:
References
NUDOCS 9106270063
Download: ML18009A946 (3)


See also: IR 05000400/1991015

Text

Docket No. 50-400

License

No. NPF-63

JUN 12 1991

Carolina

Power

and Light Company

ATTN:

Nr. Lynn W. Eury

Executive Vice President

Power Supply

P. 0.

Box 1551-

Raleigh,

NC 27602

Gentlemen:

SUBJECT:

NRC

INSPECTION

REPORT

NO. 50-400/91-15

This refers to the inspection

conducted

by J.

Tedrow of this office on

June

3 - June

7, 1991.

The inspection

included

a review of'ctivities

authorized'or your Harris facility.

At the conclusion of the inspection,

the

findings were discussed

with those

members of your staff identified in the

enclosed

inspection report.

~

~

~

~

~

Areas

examined during the inspection

are identified in the report.

Within

these

areas,

the inspection consisted

of selective

examinations

of procedures

'nd representative

records,

interviews with personnel,

and observation of

activities in progress.

Based

on the results of this inspection, certain of your activities appeared

to be in violation of NRC requirements

and are under consideration for

escalated

enforcement action in accordance

with the "General

Statement of

Policy and Procedure

for NRC Enforcement Actions" (Enforcement Policy),

10 CFR Part 2, Appendix

C (1991).

The apparent violations pertain to

a failure to

establish/implement

plant procedures

which rendered

one channel of the reactor

protection

system inoperable.

Accordingly, no Notice of Violation is being

issued at this time and

no response

to this letter is required.

However,

please

be advised that the

number

and characterization

of violations described

in the enclosed

Inspection

Report

may change

as

a result of further

NRC review.

An Enforcement

Conference

to discuss

these violations

has

been

scheduled for

July 3, 1991.

You will be advised

by separate

correspondence

of the results of

our deliberations

on this matter.

'n accordance

with 10 CFR 2.790, of the NRC's "Rules of Practice,"

a copy of

this letter and its enclosure(s) will be placed in the

NRC Public Document

Room.

9106270063

9i0612

PDR

ADQCN 05000400

Q

PDR

Carolina

Power

and Light Company

JUNE'9gi

Should you have

any questions

concerning this letter, please

contact us.

Sincerely,

Enclosure:

NRC Inspection

Report

cc w/encl:

R.

B. Richey, Vice President

Harris Nuclear Project

Box 165

New Hill, NC

27562

C. S. Hinnant

General

Manager

Harris Nuclear Plant

Box 165

'ew Hill, NC

27562

C.

S. Olexik, Jr.,

Manager

Regulatory Compliance

Harris Nuclear Project

P. 0.

Box 165

New Hill, NC

27562

Mr. H.

Ray Starling

Manager - Legal

Department

P.

0.

Box 1551

Raleigh,

NC

27602

Dayne

H. Brown, Director

Division of Radiation Protection

N.

C. Department of Environment,

Health

5 Natural

Resources

P. 0.

Box 27687

Raleigh,

NC

27611-7687

bcc w/encl:

(See

page

3)

Luis A. Reyes, Director

Division of Reactor Projects

Carolina

Power

and Light Company

JUN g g )tjg~

w

bcc w/encl:

D

ument Control

Desk

. Christensen,

RII

B. Nozafari,

NRR

NRC Resident

Inspector

U.S. Nuclear Regulatory

Commission

Route

1,

Box 315B

New Hill, NC

27562

RII:DRP

RII DRP

RII

PD

RII: D

P

RII: DRP

RI: D

S

R II:

MGIDSman

NMerriweatherfjgfChristensen

DVerrelli

EMerschoff A%

on

GJen

06/(P/91

06//( /91

06/> V/91

06/~ V/91

06/

91

06////91 06/Q, /91