Hematite Procedure: HDP-PR-FSS-701, Final Status Survey Plan Development Decommissioning Project Westinghouse Non-Proprietary Class 3 Revision: 4 Appendix P-6, Page I of I APPENDIX P-6 FSS FIELD LOG Survey Area:
LSA-10
==
Description:==
Burial Pit Open Land Area Survey Unit:
02
==
Description:==
West Central Survey Unit (North Burial Pit Area)
FSS Field Loi:;:
Date/Time:
Observation or Comment:
Technician 1/29/15 Prior to beginning GWS, a task-specific safety briefin~ was performed t the FSS J. Willams Supervisor. In the field, before GWS commenced FS crew confirmed & C
~
integrity. Background levels were measured at 9.5K- !OK (voss cpm. Entered int~
- LSA 10-01 at 1530 and commenced GWS. Weather is party cloudy and J\\Yfcroximately 50° F. No anomalies or foreign debris noted. Exit area at 1710.
es created:
LSA 10 02 012915 B MC LSA 10 02 012915 JW C 1/30/15 Prior to beginning GWS, a task-criecific safety briefin~ was performed b(. the FSS J. Williams Supervisor. In the field, before WS commenced FS crew confirmed & C integrity. Dewatering performed b? ops to allow access to low lying and previousp-J~
waterlogfed areas. Entered into L A 10-02 at 1015 and GWS performed.. Exit area at I 15. Return to area at 1255 to continue GWS. Weather is partly cloudy and approximately 40° F. One of the pits was inaccessible due to extremely soft bottom, even after dewatering. Supervisor notified and corrective actions discussed. Exited area at 1715. Files created:
LSA_10_02_013015 _B _MC LSA_l0_02_013015 _B2_MC LSA 10 02 012915 C JW LSA 10 02 012915 C2 JW 02/02/15 Prior to beginning GWS, a task-criecific safety briefin§ was performed by the FSS J. Williams Supervisor. In the field, before WS commenced FS crew confirmed I & C integrity. Entered into LSA 10-02 at 0915 to begin filling holes in GWS coverage,ra. 4 includin~ the pit discussed on 1/30/15. Some areas remain inaccessible, but acces
,/~
to them as been discussed with operations. Exit area at 1205. After operations had made the area between the fences accessible, re-enter the area at 1300.
Weather is partly cloudy and approximately 30° F. The remainder of the 10-02 GWS area completed and exit area at 1400. Files created:
- note that due to the relatively small size, file C2 LSA_10_02_020215 _C2_JW was combined into C during post processing LSA 10 02 020215 C3 JW 02/03/15 Prior to beginning field work, a task-specific safety briefing was performed b.f the J. Williams FSS Supervisor. Prior to beginning soil sam,riling, the FSS crew confirmed I C
~
- .zt;._..,
integrity. Weather is clear and in tlie mid 40 s. Systematic and Biased Samples r,;
- collected. Exit area at 1655.
FSS Field Log _1 _of_l _
Quality Record