Text

Mr. Thomas F. Plunkett President - Nuclear Division Florida Power and Light Company P.O. Box 14000 Juno Beach, Florida 33408-0420 December 3

997

SUBJECT:

CORRECTION TO NRC LETTER OF NOVEMBER 12, 1997, TURKEY POINT UNITS 3 AND 4 (TAC NOS. M93531 AND M93532)

Dear Mr. Plunkett:

By letter dated November 12, 1997, we informed you of the results of our review of your actions associated with Generic Letter 95-07, "Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves" at Turkey Point.

A portion of the safety evaluation was inadvertently omitted from this letter.

Please replace page 4 of the safety evaluation with the attached page.

~

If you have any questions regarding this matter,'please contact me at (301) 415-1475.

Sincerely,

/S/

Richard P. Croteau, Project Manager Project Directorate II-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Docket Nos. 50-250 and 50-251

Enclosure:

As stated cc w/enclosure:

S'ee next page Docket File PUBLIC OGC Turkey Pt. Rdg.

S. Tingen L. Trocine '. Boger ACRS J. Johnson T. Harris(Email SE)

Document Name: G:TURKEY>TP93531.COR To receive a copy of this document, indicate in the box: "C" = Copy without attachment/enclosure Copy'with attachment/enclosure "N" = No copy OFFICE NAME DATE PDII-3/PM RCroteau 12/5 /97 PDII-3/LA BClayton 12/9-/97 11/ 097 12/

/97 PDII-3/D FHebdo 12/9/97 OFFICIAL RECORD COPY PDR AQQGK 05000250 IP)g g P gg['lpga ~@~

'llllllllllllll,lllllliillllllllll.

C,

'C

~

1 p

"elks RFCO P0 Cy 0

0 $

/7

~O

+**++

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555<001 December 3,

1997 Mr. Thomas F. Plunkett President - Nuclear Division Florida Power and Light Company P.O. Box 14000 Juno Beach, Florida 33408-0420

SUBJECT:

CORRECTION TO NRC LETTER OF NOVEMBER 12, 1997, TURKEY POINT UNITS 3 AND 4 (TAC NOS. M93531 AND M93532)

Dear Mr. Plunkett:

By letter dated November 12, 1997, we informed you of the results of our review of your actions associated with Generic Letter 95-07, "Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves" at Turkey Point. A portion of the safety evaluation was inadvertently omitted from this letter.

Please replace page 4 of the safety evaluation with the attached page.

If you have any questions regarding this matter, please contact me at (301) 415-1475.

Sincerely,7/

Richard P. Croteau, Project Manager Project Directorate II-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Docket Nos. 50-250 and 50-251

Enclosure:

As stated cc w/enclosure:

See next page"

A

Hr. T.

F. Plunkett Florida Power and Light Company TURKEY POINT PLANT CC:

H. S.

Ross, Attorney Florida Power 8 Light Company P.O.

Box 14000 Juno

Beach, FL 33408-0420 John T. Butler, Esquire
Steel, Hector and Davis 4000 Southeast Financial Center Miami, Florida 33131-2398 Hr. Robert J.

Hovey, Site Vice President Turkey Point Nuclear Plant Florida Power and Light Company 9760 SW. 344th Street Florida City, FL 33035 Armando Vidal County Manager Metropolitan Dade County 111 NW 1 Street, 29th Floor Miami, Florida 33128 Senior Resident Inspector Turkey Point Nuclear Generating Station U.S. Nuclear Regulatory Commission P.O.

Box 1448 Homestead, Florida 33090 Hr. Bill Passetti Office of Radiation Control Department of Health and Rehabilitative Services 1317 Winewood Blvd.

Tallahassee, Florida 32399-0700 Hr. Joe Hyers, Director Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee, Florida 32399-2100 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 61 Forsyth Street, SW., Suite 23T85

Atlanta, GA 30303-3415 Attorney General Department of Legal Affairs The Capitol Tallahassee, Florida 32304 Plant Manager Turkey Point Nuclear Plant Florida Power and Light Company 9760 SW. 344th Street Florida City, FL 33035 Mr. H.N. Paduano, Manager Licensing

& Special Programs Florida Power and Light Company P.O.

Box 14000 Juno

Beach, Florida 33408-0420 Hr. Gary E. Hollinger Licensing Manager Turkey Point Nuclear Plant 9760 SW. 344th Street Florida City, FL 33035 Hr. Kerry Landis U.S. Nuclear Regulatory Commission 61 Forsyth Street, SW., Suite 23T85
Atlanta, GA 30303-3415