Turkey Point Unit 3 1992 Refueling Outage Form NIS-1 Owners'ata Report for Inservice Inspections 9303lhOOh2 9303iO PDR ADOCK 05000250 Q PDR r

k' h

t As 1~

FORM Owner:

NIS-1 OWNERS'ATA required by the Provisions of the Florida Beach, REPORT FOR INSERVICE INSPECTIONS ASME Code Rules Page 1 of 10 Power and Light Company, 700 Universe Blvd. Juno Florida 33408 2 ~ Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034 3 ~ Plant Unit: 3 Owner Certificate of Authorization (if required) ~N A 5 ~ Commercial Service Date  : December 14 1972 National Board Number for Unit: ~NA 7 ~ Components Inspected:

Manufacturer State or Nat'l Component or Manufacturer or Installer Province Board Appurtenance or Installer Serial No. No. No.

Steam Generator A Westinghouse 16A-5885-1 N/A N-740 FSGT-3001 3E210A Steam Generator B Westinghouse 16A-5885-2 N/A N-742 FSGT-3002 3E210B Steam Generator C Westinghouse 16A-5885-3 N/A N-744 FSGT-3003 3E210C Excess Letdown Heat Atlas 845 N/A 696 Exchanger Reactor Coolant Westinghouse 3P200B N/A N/A Pump B Reactor Coolant Westinghouse 3P200C N/A N/A Pump C Regenerative Heat Westinghouse 3E200 N/A N/A Exchanger Residual Heat Atlas 877 N/A 727 Exchanger A Residual Heat Westinghouse 3P210A N/A N/A Removal Pump A Residual Heat Westinghouse 3P210B N/A N/A Removal Pump B

NIS-1 Report (continued) Page 2 of 10 Owner: Florida Power and Light ComPany, 700 Universe Blvd. Juno Beach, Florida 33408 Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034 Plant Unit: 3 4, Owner Certificate of Authorization (if required) ~N A

5. Conmercial Service Date : December T4 1972
6. National Board Number for Unit: ~N A Manufacturer State or Nat'l Component or Manufacturer or Installer Province Board Appurtenance or Installer Serial No. No. No.

Reactor Coolant Bechtel N/A N/A N/A System 27.5"-RCS-1307 27.5"-RCS-1306 27.5"-RCS-1309 12"-RC-1301 4"-RC-1302 4"-RC-1303 4"-RC-1304 2"-RC-1310 Safety Injection Bechtel N/A N/A N/A System 2"-SI-1301 2U-SI-1302 Chemical and Volume Bechtel N/A N/A N/A Control System 3"-CH-1301 3"-CH-1302 3"-CH-1303 2"-CH-1302 Residual Heat Bechtel N/A N/A N/A Removal 10"-SI-2302 10"-SI-2303 8"-SI-2309 Main Steam System Bechtel N/A N/A N/A 26"-MSA-2301 26"-MSB-2302 Blowdown System Bechtel N/A N/A N/A 6"-BDA-2301 6U-BDB-2302 6"-BDC-2303

NIS-1 Report (continued) Page 3 of 10 Owner: Florida Power and Light Company, 700 Universe Blvd. Juno Beach, Florida 3340B Plant: Turkey Point Nuclear Power Plant, P.O. Box 30BB, Florida City, Florida 33034 Plant Unit: 3

4. Owner Certificate of Authorization (if required) ~N A
5. Conmercial Service Date : December 14 1972
6. National Board Neer for Unit: ~N A Manufacturer State or Nat'l Component or Manufacturer or Installer Province Board Appurtenance or Installer Serial No. No. No.

Main Feedwater Bechtel N/A N/A N/A System 14"-FWA-2301 14"-FWB-2303 14U-FWC-2305 14>>-FWC-2306 Component Cooling Bechtel N/A N/A N/A Water System Zone 118 Zone 119 Zone 123 Zone 128 Zone 129 Zone 130 Zone 132 Zone 133 Zone 134 Zone 136 Zone 137 Zone 139 Zone 141 Zone 145 Zone 150 Zone 153 Auxiliary Feedwater Bechtel N/A N/A N/A Pump Suction System Zone 164 Intake Cooling Water Bechtel N/A N/A N/A System Zone 168 Auxiliary Feedwater Bechtel N/A N/A N/A System Pump Discharge Zone 171

NIS-1 Report (continued) Page 4 of 10 Owner: Florida Power and Light Company, 700 Universe Blvd. Juno Beach, Florida 33408 Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034 Plant Unit: 3

4. Owner Certificate of Authorization (if required) ~N A
5. Comnercial Service Date : December 14 1972
6. National Board Number for Unit: ~N A
10. Abstract of examinations and statement concerning status of work required for current interval:

An Inservice Examination of selected Class 1, 2, and 3 components and piping systems of Florida Power and Light's Turkey Point Unit 3 was performed during the 1992 Refuel Outage. This outage began on October 1, 1992 and ended on December 3, 1992. This was the second outage of the third period and the sixth outage of the second ten year interval.

The components and piping systems examined were selected per the Second Ten Year Inspection Plan, which was prepared in accordance with the requirements of the 1980 Edition with addenda through Winter 1981 of ASME Section XI.

Manual ultrasonic, radiographic, visual, magnetic particle, and liquid penetrant non-destructive techniques were used to examine components, piping, and their supports. The examinations were performed by FPL personnel, supported by examiners supplied by Ebasco Services Inc.

Eddy Current examinations were conducted by FPL personnel from October 10, 1992 through October 18, 1992 on Steam Generators A, B, and C. A total of 9587 tubes were examined. See the attached NIS-BB report for the summary of examination results.

The augmented Feedwater Nozzle examination program was conducted during this outage on all three Steam Generators. The entire area from the nozzle ramp to a point one pipe diameter out on the far side of the elbow was examined with ultrasonics. No reportable indications were noted.

Snubber functional testing and visual examinations were conducted in accordance with Turkey Pt. 3 Plant Technical Specifications.

Examination and testing services were supplied by Siemens Nuclear Power Services, Inc.

System Pressure testing was conducted by the plant to applicable Plant Technical Specifications and Procedures.

The number of examinations performed during this outage and the cumulative total of exams meet the requirements of Table B of Section XI.

0 NXS-1 Report (continued) Page 5 of 10 Owner: Florida Power and Light Con@any, 700 Universe Blvd. Juno Beach, Florida 33408

2. Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034
3. Plant Unit: 3
4. Owner Certificate of Authorization (if required) ~W A
5. Comnercial Service Date : December 14 1972
6. National Board Number for Unit: ~W A 11 & 12. Abstract of Conditions Noted Abstract of Corrective Measures Recommended and Taken Class 1 Steam Generators The inlet and outlet bolting and nozzle inside radius sections were examined. No unacceptable indications were found. During these examinations, a loose nut on the steam generator support was noted and reported to the plant. This nut was tightened and an examination of the remaining nuts on all steam generators was performed. No other nuts were found to be loose. One base plate nut was found to have incomplete thread engagement. This was accepted as-is by engineering evaluation.

Reactor Coolant Pumps Visual examination methods were used to perform an examination of the 3B pump flange surface. No unacceptable conditions were noted.

Two Reactor Coolant Pump flywheels were examined during this outage. The 3C pump flywheel was volumetrically examined in place and the 3B pump flywheel was examined surface and volumetrically by Westinghouse while the pump was being refurbished in their Pittsburgh facilities (reference PC/M 92-063). The guidelines of Regulatory Guide 1.14 were followed. No unacceptable indications were noted.

Regenerative Heat Exchanger A visual examination (VT-3) was performed near the beginning of the outage to check for leakage during operation. During startup, a visual examination (VT-2) was performed to detect leakage. No unacceptable indications were noted. These examinations were performed in lieu of volumetric and surface examinations in accordance with Relief Request No. 3.

Reactor Coolant Piping The RPV inlet nozzle to safe-end dissimilar welds were examined using surface examination techniques. There were large areas that were inaccessible due to the close quarters of the opening in the RPV cavity floor. The limited examination was performed in accordance with Relief Request No. 2. No recordable indications

NIS-1 Report (continued) Page 6 of 10

1. Owner: Florida Power and Light ComPany, 700 Universe Blvd. Juno Beach, Florida 33408 2~ Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034 3~ Plant Unit: 3 4~ Owner Certificate of Authorization (if required) ~N A
5. Cemercial Service Date : December 14 1972
6. National Board Number for Unit: ~N A were found. These nozzle welds were ultrasonically examined during the previous outage.

Surface and volumetric examinations were performed on other selected piping welds. No unacceptable conditions were noted.

Safety Injection Piping Surface examinations using Liquid Penetrant methods were conducted on selected welds. No unacceptable conditions were noted.

Chemical and Volume Control Piping Surface and volumetric examinations were conducted on selected welds. No reportable indications were noted.

Other Class 1 Information FPL has recently reviewed the plant Piping and Instrumentation Drawings in an effort to incorporate, to the extent practical, the current guidelines on Section XI Code boundaries. This has resulted in several areas being reclassified to either higher or lower Quality Groups. The Seal Leakoff from the Reactor Coolant Pumps was reclassified from Class 1 to Class 2. This resulted in the elimination of these lines from volumetric and surface examination requirements due to current Class 2 exemptions.

Two scheduled examinations in Zone 040 were changed. They were originally scheduled in accordance with IWB-2420(a), so as to repeat the examinations established during the first interval.

These welds are located under the fuel transfer canal in a high radiation area that is highly contaminated with limited access.

These were changed for ALARA concerns.

FPL has examined four welds to determine has occurred as described in I.E. Bulletin 88-08.

if thermal stratification No reportable indications were noted.

1 NIS-1 Report (continued) Page 7 of 10 1 ~ Owner: Florida Power and Light Company, 700 Universe Blvd. Juno Beach, Florida 33408

2. Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034
3. Plant Unit: 3
4. Owner Certificate of Authorization (if required) ~N A
5. Comnercial Service Date : December 14 1972
6. National Board Number for Unit: ~N A Class 2 Steam Generators The secondary side of the three steam generators was visually examined at the request of the plant. Debris was found inside of Steam Generator B. These areas were cleaned. No other reportable indications were found.

The "CL" weld on steam generator B (transition cone to upper shell) was examined. This examination was performed as part of an ongoing program by FPL to monitor this weld on all the Turkey Point. Steam Generators. This is due to concern with cracking that has been detected in this weld at other plants. Acceptable slag inclusions and geometric conditions were found.

Residual Heat Removal Piping Visual examinations were performed on selected supports. Drawing discrepancies were noted. Inadequate thread engagement and paint on spherical bearings were noted. A gap was noted between the baseplate and wall on one support. These were accepted as-is or cleaned. No unacceptable conditions were found.

A linear indication was noted on a pipe to elbow weld and an integral attachment weld. These were determined to be caused by a lap surface upset and were removed by additional surface preparation.

Main Steam Piping Visual examinations were performed on one support and a surface examination was performed on the integral attachment. No unacceptable conditions were found.

Steam Generator Blowdown Piping Visual and Magnetic particle examination techniques were used on selected supports and welds. No unacceptable conditions were found.

Main Feedwater Piping

NIS-1 Report (continued) Page 8 of 10

1. O~ner: Florida Power and Light Company, 700 Universe Blvd. Juno Beach, Florida 33408
2. Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034
3. Plant Unit: 3
4. Owner Certificate of Authorization (if required) ~N A
5. Cemx.'rcial Service Date : December 14 1972
6. National Board Number for Unit: ~N A During an erosion/corrosion examination, a pit was noted on the external surface. The pit was determined to be a manufacturing anomoly, present since construction. It was repaired by welding.

Visual and Magnetic Particle examinations were performed on selected supports and their integral attachments. No unacceptable conditions were found.

Residual Heat Removal Pumps The RHR pumps were visually examined to check for leakage from the pump body. Leakage was noted coming from the flange surface. This condition was accepted as-is, but will be corrected under a Plant Work Order at a later date. No other indications were noted.

Excess Letdown Heat Exchanger An Ultrasonic examination of one weld and its associated longitudinal seam weld was conducted. Geometry from the weld on the interior divider plate was noted. No unacceptable conditions were found.

Class 3 Component Cooling Water Visual examinations were performed on selected supports and integral attachments. An oversize bolt on one support baseplate, the incorrect number of washers and nuts were installed on two supports, incomplete thread engagement, chipped concrete, a painted spherical bearing, and a bent rod and inadequate cotter pin on other supports were noted. These were all accepted by engineering evaluation as performing their intended function. The pin was replaced and the spring can was returned to its design condition.

One integral attachment was reported to have broken tack welds.

These were cleaned and the indications were determined to be false indications caused by painted slag with cold lap, causing a misidentification of the indications.

Auxiliary Feedwater Pump Suction Visual examination of one support and its integral attachment, was conducted. No unacceptable conditions were found.

k NIS-1 Report (continued) Page 9 of 10 e,, 4~

5.

Owner:

Plant:

Owner Florida Power and Light ComPany, 700 Universe Blvd. Juno Beach, Florida 33408 Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034 Plant Unit: 3 Certificate of Authorization Carmercial Service Date : December (if required) 14 1972

~N A

6. National Board Number for Unit: ~N A Intake Cooling Water A Visual examination of one support and its integral attachment was conducted. No unacceptable conditions were found.

Auxiliary Feedwater Pump Discharge Visual examination of a support and its integral attachment was conducted. No unacceptable conditions were found.

Other reports:

Report Organization Description of Services Number Florida Power and Snubber Inspections 0 N/A Light Florida Light Power and System Pressure Tests

NIS-1 Report (continued) Page 10 of 10 Owner: Florida Power and Light Company, 700 Universe Blvd. Juno Beach, Florida 33408 Plant: Turkey Point Nuclear Power Plant, P.O. Box 3088, Florida City, Florida 33034 Plant Unit: 3 4~ Owner Certificate of Authorization (if required> ~N A

5. Camercial Service Date : December 14 1972
6. National Board Number for Unit: ~N A We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code,Section XI. j)/fan; OWNER : FLORIDA POWER AND LIGHT COMPANY ay; . Pg ro I + + /7&(rll/ w 3/8/ U CERTIFICATE OF AUTHORIZATION NO. (IF APPLICABLE): N/A EXPIRATION DATE: N/A CERTIFICATE OF INSERVXCE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/ or the State or Province of Dade County and employed by Arkwright.

Mutual Xnsurance Company of Norwood, Massachusetts have inspected the components described in this Owners'ata Report during the knowledge and belief, the Owner has performed examinations and taken corrective measures described in the Owners'ata Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, and neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Insp c r's Signature

/ jN'o (A)(2J National Board, State, Province, and Endorsements Date: kAt4

I d 4 i ~

Turkey Point Unit 3 1992 Refueling Outage Form NIS-BB Owners'ata Report of Eddy Current Examinations

paqQ ) 04 Z Eddy Current Summary of Results Plant: Turkey Point 3 Examination Dates: 10/10/92 Through 10/18/92 Tubes Steam Total Total Ind. Total1004'otal Ind. Plugged as Total Generator Tubes > 20% 40 Preventive Tubes Number Inspected to 394 to Maintenance Plugged 3E210A 3199 72 NONE 3E210B 3200 95 NONE 3E210C 3188 73 Location of Indications Drilled Support Top of Tube Sheet Steam AVB 1 through 6 to 1 Drilled Support Generator Bars Cold Leg Hot Leg Cold Leg Hot Leg 3E210A 37 13 3E210B 44 22 17 NONE 12 3E210C 59 Certification of Record We certify that the statements in this record are correct and the tubes inspected were tested in accordance with the requirements of Section XI of the ASME Code.

FLORIDA POWER and LIGHT COMPANY Organization Date: >> + 9 ~ Prepared By:

S/G E dy Current Coordinator Date: /2/8/e Z Reviewed By:

I i?

pections Su o.

rvisor

Form,NIS-BB Owners'eport for Eddy Current Examination Results Page 2 of 2 Steam Generator Tubes Plugged Plant: Turkey Point 3 Steam Generator Steam Generator Steam Generator 3E210A 3E210B 3E210C Row Column Remarks Row Column Remarks Row Column Remarks 21 32 444 42 45 PTP 33 39 35 41 55 604 20 66 41%'54 70 PTP Preventive tube plug based on memos attached to CNR 4 92-3-031 and 032.

The following cumulative listings are attached for each steam generator.

~ Cumulative Distribution Summary

~ Pluggable Indications

~ Indications 20 394

CUMMULATIVE DISTRIBUTION

SUMMARY

TURKEY POINT UNIT g 3 09/92 COMPONENT : S/G A Page  : 1 of 1 Date  : 11/16/92 Time  : 11:30 AM Examination Dates: 10/10/92 thru 10/18/92 Total Number of Tubes InsPected .....: 3199 Total Indications Between 204 and 394 72 Greater than or equal to 404 1 Total Tubes Plugged as Preventive Maint Total Tubes Plugged Location Of Indications 204 to 1004 Hot Leg Cold Leg TSH .5 to 01H -2.1 4 TSC .5 to 01C -2.1 01H -2.0 to 06H +2.0 : 14 01C -2.0 to 06C +2.0 : 13 06H +2.1 to AV1 -3.1 : 21 06C +2.1 to AV4 -3.1 : 3 AV1 -3.0 to AV4 -3.0 : 13

'J

,~ 1

CUHULATIVE EXAHIHATION REPORT PTH-3 OUTAGE  : 09/92 COHPONENT  : S/0 A Page : 1 of 1 OESCRIPTIOH : PLUCCABLE IHDICATIOHS Date : 11/13/92 Time : 9:00 AH I I Extent 09/92 I I N/A I IRovlCoIILeglReqlTst/Hotel Reel I Probe Location IyoltalpeglCh I X, IDiffl Location lyoltslDeglCh I x I

'--I.-.I---I- I

. .- I-.---.--I I I I I

- I-- I--.- I---.--------I.---- I---I--- I--+

21I 32I ITEHITEH PSIAC012-03IA-720.H/ULC I06H 2.3 1.3I135I 1I 44I I C

'---I.--I---I- I I -I- I I

I I I

-I-.I--I-------I.--I--I--I--+

I I I I I I Number of RECORDS Selected from Current Outage Nurher of TUBES Selected from Current Outage :

TJ 1

CUMULATIVE EXAMINATION REPORT PTN-3 OUTAGE  : 09/92 COMPONENT  : S/G A Page : 1of2 DESCRIPTION: 20X TO 39X Date : 11/13/92 Time : 9:00 AM

+

I ( Extent I I 09/92 I N/A I (RoM(CoI)Leg(Req(Tst/ Mote( Reel I Probe I Loc at)on (Volts(oeg(CK (

X [Diff( ation (Volts(oeg)CH ) X (

+ I I

.I.--I----- --I. I

-I--- I

. -I I

-I--+

I zl 4[ c )O6c)O6c IAC001-01IA-720.M/ULC lose 44.1 .5(149( 1( 30( I I I I 9I 4I c ITEHITEH PSIAC004 01IA 720.M/ULC (06H 2.4 .6(1s1( 30( I I I (13[ s(c ITEN[TEN [AC006-02[A-720.M/ULC (TSH 3.6 1.1 I157I 1 I z6)

( ( (c ITEHITEH IAH030 07(MRPCT20 3C/TITSK 3.9 41131[ 11 3a(

9[ 6(c ITEHITEH IAC004 1[A 720 M/ULC (06H 2.5 .4)1sn) 31 I 7(c (TEHITEH PCIAC006-02(A-720.M/ULC )TSH 2.7 ~ 2I152I 1I 9[ 11( c ITEHITEH IAC004-01(A-720-M/ULC (06H 2.5 .7(149[ 32(

I 9I 12I c ITEHITEH [AC005-01 ) A-720.M/ULC [06H 2.4 1.21160 I 1 I 22(

9) 13[ c ITEHITEH PSIAC005 01[A 720 M/ULC l06H 2.4 ~ 6I148[ 1( 33(

I 19( 13( C (TEH(TEH Pc(ACOOT-02(A-720 M/ULC (OZC 2'I.s .7I 140 I 39(

s( 14( c ITEHITEH IAc005-01IA-720.M/ULc [06H 2.3 .SI152I 1I 30)

I 10I 16I c ITEHITEH IAC005 01(A 720 M/ULC l02C 23.9 ~ 9[146( 1 I 3S) 9( 18) c ITEHITEH IAC005-01IA-720.M/ULC I06H 2.4 ~ 8l158I 1I 24) s( ao) c ITEH ITEH IAC005-01IA-720.M/ULC I06H 2.3 1 ~ 1(151[ I I 3O[

I 9[ 21) c )TEH)TEH [AC005-01)A-720.M/ULC [06H 2.2 1.o)1sz) 30(

s( as( c (TEH(TEH SSIAC006-02IA-720-M/ULC I06H 2.3 81148[ I I 34(

( 22( 30( c ITEHITEH PC IAC012-03 IA-720.M/ULC 104N 28.8 ~ 6[162( 1[ 21(

( aS/ 31) c ITEH(TEH SS IAC012-03 IA-720.M/ULC I 01H 12.9 8[1601 1 I Z3) a( 3z( c (06c)o6c PS)AC001-01)A-720.M/ULC [OSC 43.1 ~ 5I158I 1I 22[

[ 1r) 3z[ K ITECITEC Pc[AH 28 06(A 720 M/ULc [01c 10.6 ~ 5[154 loon I I 17[ 34( K ITECITEC PSIAH028-06)A-720.M/ULC l01H 24.4 .4) 151 [

I 18[ 3rl K ITECITEC IAH029-07(A-720.M/ULC l01C 3.1 .7(1sS( 25(

( as/ 37( K ITECITEC IAH029-Or(A-720-M/ULC IOIC 3.1 9[160[ 1 I I 21(38( c ITEHIAV3 (AK032.08)MRPC680-5FH (AY2 12.5 2.2(147( as)

[ zs( 4o( c ITEH(TEH PS(AC014-04)A-720.M/ULC )02H 18.8 ~ 6)160( 1 I

[ 33( 41) c ITEHITEH Pc[AC018-05)A-720.M/ULC [AV1 .0 .8[ (I 2( as[

Ic ITEHITEH CIAC018 05(A 720.M/ULC IAV3 .0 .s) [I 2[ 23(

I 31( 44[ c ITEHITEH PS)AC019-05)A-720-M/ULC (AV3 .0 .s( (p 2) as/

I 17I 45( H (TEC)TEC IAH029-07[A-720.M/ULC (02H 3.9 1.0I155I 1I 28(

I 38I 45I c ITEH(TEH PS [AC019-05 (A-720-M/ULC (AV2 .0 (I 2( 26(

Ic ITEH[TEH PSIAC019 05[A 720.M/ULC IAV3 .0 .s) 25I ITECITEC PS(AH033-08)A-720.M/ULC )06H 5.4 ~ 6I150I 1I 32(

) 24[ 47) H ITECITEC PSIAH017-03(A-720.M/ULC IAV1 .0 1.4( IP 2) as)

I 37I 47I c ITEHITEH PS(AC019-05)A-720.M/ULC )AV3 .0 24(

I zzl s1[ K ITECITEC IAH027 06(A 720 M/ULC l06C 3.5 37(

( aa( 52[ H ITECITEC AH018-03[A-720-M/ULC 104K 40.9 .9I141 I 1I IH ITECITEC IAK030-07(MRPC720-3C/7(04H 42.4 .9I116I 1I 39(

I 30I 52I H ITEcITEc PSIAH018-03IA-720.M/ULC )AV3 .0 ~ 4[ IP zl 23[

2( s4[ c (o6c[o6c ps[Acooz-o1)A-720-M/ULC Ioic 3.3 .4) 163[ 1) a1(

I >>I ssl K ITEc(TEC Ps[AH 25 05[A 720 M/ULc )Tsc 8.3 1.2)149[ 1( 34)

I 30( 58( H )TECITEC IAH 19 04)A 720 M/ULC )AV1 .0 1.s( IP 2) 3o(

I I I H ITEGITEc [AH019-04(A-720.M/ULC (AVZ .0 1.o( (I 2) ar(

( ) H (TEC(TEC (AH019-04(A-720.M/ULC [AV3 .0 1.s( )I a( 3o(

+ I I I I I

.-I- I I

l CUHULATlVE EXAHINATlON REPORT PTN-3 OUTAGE  : 09/92 COHPONEHT : S/0 A Page 2of2 DESCRlPTION: 20K TO 39K Date : 11/13/92 Time : 9:00 AH I I Extent I I 09/92 I I N/A I fRow( ColfLeg(Req(Tst/ Note( Reel Probe Location (Volts(geg(Ch ll (Diff( Location (volts(Beg(eh x f

+- I I I I

". --I-- I

--I -I.(

I I I I

-I--I"-'

I I I H ITECITEc IAH019 04(A 720 H/ULC IAV4 .0 rl . (P zl zs( ( I I >>I 59( H ITECITEC IAH019-04IA 720-H/ULC IAV2 .0 rl (P z( 24( I I I I I H ITEGITEC IAH019 04(A 720 M/ULC (AV3 .0 .6( 2( 24( I I I>>l 59( H ITEC(TEC IAH019-04(A.720-H/ULc (OSH 25.7 1.2 I 160 I I I I I H ITECITEC IAH019 04(A 72 H/ULC (OSC 36.4 1.3I162I 1( z1( I 59( H ITECITEC PSIAH034-08IA-720 H/ULC (06K 4.6 .s(148( 1( 34( I I 38( 65( c (TEHITEH SC(AC022-05(A-720.H/ULC (AVZ .0 7( IP I I 9( 67I K ITECITEC PSIAH009-02IA 720-SF/RH ITSC 46.0 91149( 1( 32( I I zol 68( H (TECITFC PSIAH027-06IA 720 H/ULC (04H 42.2 .3(159( 1( z4( I

( 19( 69I H ITECITEC PSIAH027 06IA 720-H/ULC (03C 41.0 ~ 3I149I 1( 33( I I 27I 7 I H ITEc(TEc IAK021-04IA-720.H/ULC (01H 45.8 10l>>9( 1( 24(

I 30l 71I H ITECITEC PCIAH021-04(A-720.H/ULC (04C 2.8 3(145 I 1( 37I I 1( r3( c (06c(06c IAC003-01IA.720.H/ULC IBAC 13.6 .s(147(

( 37( 73( H (TEC(TEC (AH023-05(A-720-M/ULC (04K 36.8 ~ S(148( 1( 34(

I 4( 74I H ITECITEC IAH011 01(A 720 H/ULC (03H 9.1 1.6 I 145 I I 32I 75( H ITECITEC (AH023-05(A.720 H/ULC IAV3 2.1 8(143 IP 2( zs(

I 9( 76( H (TEc(TEC SS(AH011 01(A 720 H/ULC (03c 43.1 .4(143(

I I H ITECITEC IAH011 01(A-720 H/ULC (02c 16.7 1.0(144( 1( 3r(

I 1( 81I C I06CI06C IAC003 01(A 72 H/ULC (BAC 16.0 .s(1ss( 1( 27(

I 22I 81( H ITECITEC IAH022-OSIA-720 H/ULC (OSH 40.5 ~ 3(138(P I 9( 82I H ITECITEC IAH012-02IA-720 H/ULC (06H 2.9 .9I146I 1I 35I f z4( 82I H ITECITEC SC(AH022 05(A-720.H/ULC (06C 4. 'l 1.1 (158 I 1( zs(

I 9( 83( H ITEC(TEC SSIAH012 02(A 720.H/ULC (06H 2.6 1.1I145I 1I 36I I 1( 84( c (06c(06c IAC003 01(A 720.H/ULC IBAC '16.6 1 2(>>rl 1( zs(

84( H (TEC(TEC IAH015-03IA-720-H/ULC ITSH .9 .4 I 159I 1( 22(

I 9( 85I H ITECITEC IAH012 02(A 720 H/ULC l06H 2.4 91144(

I 9( 86( H ITECITEC IAH012 0 IA 72 H/ULC l06H 2.3 1.7(162( 1( zo(

I 9( 90I H ITEGITEC IAH012 02IA-720.H/ULC I06H 2.4 ( 1.z(1s9( 1( 23(

I 1z( 90( H ITECITEC SIAH016 03(A 720 H/ULC (04K -.5 1( 32(

+---( ---I--I- I I----------. -.-I- I I Number of RECORDS Selected from Current Outage 72 Naker of TUBES Selected from Current Outage : 62

~ >

CUMMULATIVE DISTRIBUTION

SUMMARY

TURKEY POINT UNIT 4 3 09/92 COMPONENT : S/G B Page  : 1 of 1 Date  : 11/16/92 Time  : ll:30 AM Examination Dates: 10/10/92 thru 10/18/92 Total Number of Tubes Inspected .....: 3200 Total Indications Between 204 and 394 95 Greater than or equal to 404 0 Total Tubes Plugged as Preventive Maint Total Tubes Plugged Location Of Indications 204 to 1004 Hot Leg Cold Leg TSH. .5 to 01H -2. 1 12 TSC .5 to 01C -2.1 : 0 01H -2.0 to 06H +2.0 17 01C -2.0 to 06C +2.0 : 22 06H +2.1 to AV1 -3.1 13 06C +2.1 to AV4 -3.1 : 10 AV1 -3.0 to AV4 -3.0 21

CUHULATIVE EXAMIHATIOM REPORT PTH.3 OUTAGE  : 09/92 COHPONEHT  : S/G 8 Page : 1 of 1 DESCRIPTIOH  : PLUGGABLE IHDICATIONS Date: 11/13/92 Time: 9:00 AN

+

(' Extent I 09/92 I ( H/A I (Row(Col(Leg(Req(Tst/Mote( Reel ( Probe Location (Volts(Deg(Ch (

X (Diff( Location (Volts(Deg(Ch (

X (

I I I I

.--. -I- ------I- I ( I I

-I---I-- -I-------I---I--I--I--'0(

I 42( 45( C ITEHITEH *H IBC025-07(A.720.N/ULC (AV2 2.2( (35X(PTP(

I I I I .I --I I I.- I ( I. I. I-- --- ----- II----I--I--I.--+

I I I I Hunber of RECORDS Selected from Current Outage Hwher of TUBES Selected from Current Outage:

CUHULATI VE EXAHIKATION REPORT PTN-3 OUTAGE : 09/92 COHPOHENT: S/G B Page 1of3 DESCRIPTION: 20K TO 39X Date : 11/13/92 Time : 9:00 AH

+

I (

Extent I I 09/92 I IRoM(Col(Leg(Req(Tst /Note( Probe Location (Volts(oeg(ch ( X (Diff( Location (Volts(Deg(Ch x I--- I---------I----- I---

Reel I I

+" I I I I I I

-I- -.--- I -I - . - I.-- I- -

I

+

11( 2( c ITEHITEH Ps(scoos-03(A-720-sF/RH (O2C 37.0 I .511471 11 301 I I I I I 10( I c ITEHITEH Iscoo6-o2(A-720-H/ULC (O2C 31.8 I .811541 11 221 I I 211 61 c ITEHITEH PC(BC011-03(A-720-H/ULC 105H 34.3 I .3(135( 1( 38( I I 101 71 C ITEHITEH IBC006-02IA-720.H/ULC Io2c 31.7 I .611551 11 211 I SI 8( c ITEN(TEN IBC006 02(A.720.H/ULC (SAH 15.9 I .711561 11 201 I I I I c ITEHITEH IBC006-02IA 720-H/ULC 104H 15.0 I 1.8(154( 1( 22( I IBC006-02IA-720.H/ULC 7 ~ 6(123IP 11 301 I SI SI c ITEHITEH 101H ~

I I 11( 9( C ITEN(TEH PCIBC009 03(A-720-SF/RH (O2C 36.6 I .4(141( 1( 36( I I 23( 91 c ITEHITEH (BC011-03(A-720-H/ULC 106H 4.0 I 1.4(143( 1( 32( I I C (TEH(TEH (BC011-03(A-720.H/ULC (osc 31.2 I .711541 11 221 I I I I c ITEHITEH (BC011-03(A.720.H/ULC lose 18.5 I ~ 31140( 1( 361 I I 111 101 C ITEHITEH PSIBC009-03IA 720-SF/RH 102C 36.7 I 6(141( 11 36(

I 23( 101 C ITEHITEH IBC011-03(A-720-H/ULC 106H 4' I 1.311441 11 331 I 10( 11( c ITEHITEH PS(BC006-02(A.720.H/ULC 102C 3'I.9 I .3(14s( 1( 3o(

I 111 111 c ITEHITEH SS(BC009-03(A.720-SF/RH Io2c 36.7 I .711571 11 201 I 181 121 C ITEHITEH PCIBC009 03IA-720.SF/RH IOSH 19.8 I .S(141( 1( 36(

I 191 121 c ITEHITEH PS(BC009-03(A.720-SF/RH ITSH .7 I .611371 11 391 29( 12( C ITEHITEH PS (BC011-03 (A-720-H/ULC IAV1 .0 2( 23(

20( 13( C ITEHITEH PC(BC009-03(A 720-SF/RH (04H 15.4 .3(148( 1( 29(

61 141 c ITEHITEH SSIBC006-02IA-720.H/ULC 102H 32.2 .911441 331 151 C ITEHITEH PSIBC016-05(A-720-H/ULC IAV2 .0 F 51 IP 2( 21(

36( 19( C (TEH(TEH PSIBC016.05(A-720-H/ULC (AV2 .0 .s( 21 211 261 201 C ITEHITEH PSIBC012-04(A-720-H/ULC IAV4 .0 51 IP 2( 23(

371 201 C ITEHITEH PSIBC016-05(A.720.H/ULC ITSH .6 '.511451 1( 3o(

331 211 C ITEHITEH SS(BC016-05(A 720-H/ULC (06H 4.8 1 011541 1( 22(

33( 23( c ITEN(TEN SS(BC016.05(A-720-H/ULC (06H 5.0 .7(136( 11 381 40( 25( c ITEHITEH IBC01 05(A 720 H/ULC lo C 39.3 .S(14S( 11 301 331 261 C ITEHITEH Pc(BC017-05(A.720-H/ULC (O6H 5.1 .6(141(

401 261 C ITEHITEH PSIBC017-05(A-720-H/ULC IAV3 .0 2( 21(

40( 27( C ITEII(TEH PSIBC01 5IA 720 H/ULC IAV2 .0 .51 (P 2( 23(

28( 28( c ITEN(TEN PSIBC013-04(A-720-H/ULC 103C 34.2 1.011351 1( 38(

331 291 C ITEHITEH PS(BC017-05(A 720-H/ULC (06H 5.0 .5(139( 1( 35(

39( 30( C ITEHITEH SS(BC017.05(A 720 H/ULC I C 45.7 .5(154( 1( 21(

111 311 H ITECITEC PSIBH005 01IA-720-H/ULC 102C 37.2 ~ 311511 1( 26(

34( 31( C ITEHITEH PS(BC017-05(A 720-H/ULC (AV2 .0 2( 22(

6( 321 H ITECITEc IBH 7IA 72 H/ULC ITSH 39.0 .8(146( 1( 32(

51 341 H ITEGITEC IBH 2 07(A 720 H/ULC ITSH 31.6 .6(1S1( 1( 27(

6( 34( H ITECITEC PSIBH025-07IA-720.H/ULC ITSH 38.4 .411371 11 391 32( 34( C ITEH(TEH SSIBC017-05IA-720.H/ULC IAV3 .0 .8( 3( 22(

I I C ITEHITE SSIBC017-05IA-720-H/ULC (AV4 .0 .6( 31 201 5( 35( H (TEc(TEC IBH025 07(A 720.H/ULC ITSH 33.5 .5(140( 1( 36(

~, 61 361 c ITEHITEH 441 361 c ITEHITEH

--I---I- I I PC(BC027-08(A-720.H/ULC (TSH 37.5 SSIBC025-07IA-720-H/ULC IAV1 I

---".I- --- -----I---

.0 1

~

---I--

7(1361 01 IP I

--I- -I-

CUMULATI VE EXAMIHAT ION REPORT PTN-3 OUTAGE  : 09/92 COMPONENT  : S/0 8 Page  : 2 of 3 DESCRIPTION  : 20X TO 39X Date: 11/13/92 Time: 9:00 AM

( Extent I I 09/92 I I N/A I Rcw (Col (Leg IReqlTst /Note( Reel Probe Location (volts(Deglch X (Diff( Location (Volts(oeg(Ch xl

.1 -- I- I I-" -. 1-(

1 I. --(---- I- - l--(--I-1 I I

(

.I---I- +

14( 37( H ITECITEC PSIBH005-01(A-720.M/ULC lozc 46.5 .2(151( 1( 26( I I I I 42( 37( C ITEH(TEH PSIBC025-07(A-720.M/ULC (TSH .8 1.0(1381 11 371 1 ( I

<<( 37( c ITEHITEH PS(BC025-07(A-720-M/ULC (AV4 .0 ~ 41 IP zl 231 341 381 C (TEH(TEH IBC019.06(A-720.M/ULC IAV2 .0 2-2( lP 3( >>I 1

c ITEKlTEH SS(BCD19-06(a-720-M/ULC (AV3 .0 1.sl (P 3( 3o(

42( 38( C (TEH(ZEH IBC025-07(A-720.M/ULC ITSH 1.4 1.1(1501 11 25(

(C (TEH(TEH (BC025.07(A-720-M/ULC (TSH 3.2 .5(1491 1( 26(

111 391 H ITECITEC PS(BK006-02(A-720.M/ULC 101H 12.0 .511441 11 321 391 39( C ITEHITEH (BC019-06(A-720.M/ULC (OSK .8 '1.51111(P 11 39 44( 40( C ITEHITEH PSIBC025-07(A.720.M/ULC IAV1 .0 ~ s( (P 2( 24(

14( 42( H ITECITEC PSIBH006 02(A 72 M/ULC (O3H 21.1 .5(156( 1( 21(

441 42( C (TEH('TEH PSIBC025-07(A-720-M/ULC IAV1 .0 61 (P 3( 20(

6( 441 C ITEHITSH PSIBC027-08(A-720.M/ULC ITSH 39.3 1 6(142( 1( 32(

191 44( H ITECITEC SSIBH006 02(A 720.M/ULC (O2K 32.0 .8(>>9( 1( 36(

42( 45( C (TEH(TEH (BC025-07(A-720.M/ULC (AV2 .0 z.z( (r zl 3sl I IC ITEHITEH IBC025 07(A 720-M/ULC .0 .9( (P 2( zs(

34( 461 C (TEK(TEK PCIBC020 061A 72 M/ULC (avz .0 (p z( zs(

I IC (TEH(TEH Pc(BC020-06(A-720-M/ULC lav3 .0 1.51 IP 21 31(

35( 481 C ITEHITEH PSIBC021-06(A-720.M/ULC (AV2 ~ 0 .s( ll z( 26(

(C ITEHITEH ps(ec021.06(A.720.M/ULc (AV3 .0 (P zl 27(

61 491 C ITEHITSH PS(BC028.08(A 720-M/ULC lozc 17.4 .7(141(

26( 49( K (TEC(TEC (BH027-08(A-720-M/ULC lozc 15.7 .411351 11 39(

45( 491 C (TEH(TEH IBC026-07(A-720-M/ULC (AV4 .0 .S( (P Z( 22(

17( 50( H ITECITEC PS(BH007-02(A-720.M/ULC lo3H 25.0 .4(1471 1( 281 341 511 C (TEH(TEH PSIBC021-06(A-720.M/ULC IAV2 .0 1.3( (I zl 3ol (C ITEHITEH PS(BC021.06(A-720.M/ULC lAV3 .0 (P 2( z6(

34( 53( C ITEHlTEK PS(BCOZ1-06(A-720 M/ULC lavl .0 (I z( 27(

(C (TEH(TEH PS(BC021-06(A-720.M/ULC lavz .0 ~ 6( (P 2( 26(

lc (TEH(TEH Pslecozl-o6(a-720-M/ULC .0 .s( (I 2( 26(

26( 541 H ITECITEC PS(BH017-05(A-720.M/ULC (03C 40.3 .4(1471 11 281 29( SS( H ITECITEC PS(BH017.05(A-720-M/ULC (01c 18.1 .5(155( 1( 20(

42( 551 C (TEK(TEH PS(BC026-07(A-720.M/ULC (avz ~ 0 .4( (s 2( 21(

I IC (TEH(TEH (BC026-07(A 720-M/ULC (AV3 .0 1.o( (r 2( z6(

44( S7( c ITEHITEC sc(BH034-08(a-720-M/ULC IAV4 .0 1.2( (P 3( 24(

431 60( C ITEHITEC PS(BH034-OS(A-720.M/ULC (AV4 .0 .s( (P zl 27(

351 66( C (TEH(TEH S IBC029 08(A 720 M/ULC lo6c .5 .6(124(P 1( 27(

4o( as( c ITEKITEH PS(BC024.07(A-720-M/ULC (av4 .0 (s 2( 23(

391 69( C ITEHITEC PsleH034 08(A-720.M/ULc IAV2 .0 (p z( z6(

27( 7o( K (TEC(TEC SCIBH019.05(A-720.M/ULC (06H 4.8 ~ 4(142( 1( 361 z9( 7o( H (TECITEC PSIBH019-05(A-720.M/ULC IOSH 33.1 .3(136(

251 71! H (TEC(TEC SS(BH019-05(A-720-M/ULC 106H 3.0 .6(137( 11 391

( ITECITEC I H019 05(A 720 M/ULC (04C 37.5 .5(144( 'I( 30(

l11 721 H (TEC(TEC PSIBH009.03(A-720 M/ULC (O2K 36.6 6(154( 11 zzl

---I---I"-I- -I- I I I

--I----I- I I I

CUMULATIVE EXAMINATION REPORT PTN 3 OUTAGE  : 09/92 COMPONENT  : S/0 B Page : 3 of 3 DESCRIPTIOH : 20X TO 39X Date : 11/13/92 Tfme : 9:00 AM I (

Extent I 09/92 H/A I (Roe(Col(Leg(Req(Tst/Note( Reel Probe Locatfon (Volts(Deg(Ch X (Diff( Locatfon (Volts(Deg(Ch X (

.-I-.--- I"-----.I-.--.--.--I---- I.-------.-- ----I--

( ( ( (

+ I I I I I

- I.-- I--- I---- I +

ITECITEC PC(BH021-06(A.720-M/ULC (06C 5.4 I 1.2(155( 1(20( I I I I I 35I 741 H ITECITEC PCIBH021-06(A.720.M/ULC (06C 5.6 .7(149( 1( 26( I I I I 28( 75( H ITECITEC PS(BK020.06(A.720.M/ULC I04C 32.2 .4(151( 1( 26(

I 34( 75( H ITECITEC PCIBH021-06IA-720.M/ULC (06C 5.5 .7(152( 1( 23(

( 35( 75( H ITECITEC PCIBH021-06IA 720 M/ULC I02C .7 .5(140( 1( 34(

I 11( 76( H ITECITEC IBM 13 04(A 720 M/ULC (02H 36.0 .4(141( 1( 38(

( 11( 78( H ITECITEC PS(BH013-04(A 720-M/ULC (01H 10.9 I .4(>>6( 1( 23( I I 11( 851 H ITECITEC PSIBH014 04(A 720.M/ULC I02H 36.5 .8(155( 1( 22(

11( 89( H ITECITEC PSIBH015-04IA-720-M/ULC I02H 36.1 .5(138( 1( 34(

'--I"-I- I

---I-----.-I-.-"-.---I I

. I- -I- -I- -I- I +

Number of RECORDS Selected from Current Outage: 95 Number of TUBES Selected from Current Outage ! 81

CUMMULATIVE DISTRIBUTION

SUMMARY

TURKEY POINT UNIT 5 3 09/92 COMPONENT : S/G C Page  : 1 of 1 Date  : 11/16/92 Time  : 11:30 AM Examination Dates: 10/10/92 thru 10/18/92 Total Number of Tubes Inspected .....: 3188 Total Indications Between 204 and 39% 73 Greater than or equal to 404 3 Total Tubes Plugged as Preventive Maint Total Tubes Plugged Location Of Indications 204 to 100%

Hot Leg Cold Leg TSH -.5 to 01H -2.1 2 TSC .5 to 01C -2.1 : 3 01H -2.0 to 06H +2.0 6 01C -2.0 to 06C +2.0 : 6 06H +2.1 to AV1 -3.1 9 06C +2.1 to AV4 -3.1 : 13 AV1 -3.0 to AV4 -3.0 37

~

4 ~ )

CUHULATI VE EXANINAT ION REPORT PTN 3 OUTAGE  : 09/92 COHPOHEHT  : S/G C Page : 1 of 1 DESCRIPTION  : PLUGGABLE IHDICATIOHS Date: 11/13/92 Time : 9:00 PH

+

( Extent I I 09/92 H/A I Location (Diff( Location

'-.-I-- I

" I-- I--.-.---I.- ""

(Row(Col(Leg(Req(Tst/Note( Reel (

I Probe I

(Volts(Deg(Ch I----- I--- I--- I I X "I --- I-- -----.-

(Volts(Oeg(Ch "I---"I--- I-" ( X (

I.-'0(

( 33( 39( C (TEH(TEH N (CC024-05(A 720-N/ULC IAV1 2.3( (35X(PTP( I I I I I I 35( 41( C ITEHITEH *H ICC024-05(A 720-N/ULC IAV1 ~ 0( 2.4( (35II(PTr I I I I I

( 2( 55( C (06C(06C PC(CC003.01(A.720.H/ULC (TSC 24.1 I .3(105( 1l 60( ( I I I I I 20( 66( H ITECITEC PCICH01 03(A 720 H/ULC (06C 2.4 I .6 I 134 I 1 I 41 I I I I I I

( 2( 70( C (06C(06C PC(CC003-O'IIA 720.N/ULC (02C ~ 7 .5(107( 1( 45( I I I I

'--- I-- I--- I--- I--"-.I-.----I I

- I

. I -I I--I--.-I---.---.--I-----I--I---I--'umber of RECORDS Selected from Current Outage : 5 Nuaber of TUBES Selected from Current Outage : 5

CUHULATI VE EXANIMATIDM REPORT PTM-3 OUTAGE  : 09/92 CONPOKEMT : S/G C Page 1of2 DESCRIPTIOM: 20X TO 39X Date : 11/13/92 Time : 9:00 AH

( Extent 09/92 I I I H/A Row(col(Leg (R~(Tst /Mote( Reel Probe Location (volta(gag(eh x (Diff( Location (voltslDeg(ch X

+

I

--I --I--I- I I

(

-.I- .--- I I I

- I--- I-- I.--- I.----- ---- I-- I-- I---I-.+

( ( (

I 31 101 H (o6c(o6c PSICH001 01IA 700.SF/RN (OZK 34.9 ( .9(1421 1( 34( ( I I I 61 121 c (TEN(TEN P ICC006 01(A 720 H/ULC (ozc 11.1 I .6(142( 1(>>I I I I I 261 1st c ITEHITEH ICC017 03(A 72 H/ULC IOSH cc.r .8(141( I I I 211 191 c ITEH(TEK SCICC017-03tA.720.H/ULC IAV4 .3 I .91 IP zl 23( I I 37( Z8( C ITEHITEH sslcc023-05th-720-N/ULC IAV4 .0 3( 24( I I I 301 301 C ITEHITEH SS(CC018-03(A 720.N/ULC IAV4 .0 ~

st IP 3( zC( I I I 391 301 c ITEHITEH SS(CC023-05(A.720-H/ULC Ihvz 18.8 1.3(>>zl 1( zs( I I I 301 311 c ITEHITEH PSICC018 03(A 720 H/ULC (av3 .0 z( zz( I I I 331 311 C (TEHITEH StCC023 05(A 720 N/ULC (AV3 .0 ~ rl IP I I I 41 33( K ITECITEC ICH029 07IA 720 H/ULC (TSC 27.2 .s(14z( I I I I 33( c ITEH106C SSICH034 09IA 720 N/ULC (av3 .0 ~ 61 IP 2( 23( I I I 41 341 H ITECITEC ICH029 07(A 720 H/ULC (TSC 27.3 .711471 11 zr( 'I I I 351 351 c ICC023 OS(A 72 N/ULC (av3 .0 ~ st IP zl 231 I I I I 351 361 c (TEH(TEH ICC024-05IA 720 H/ULC (AV2 ~ 0 .S( zl 23( I I I (C ITEHITEH ICC02C 05(A 720.N/ULC (AV3 .0 .s( zl 231 I I I 81 391 c ITEHITEH PSICC026 06(A 72 N/ULC 103C 48.3 .811341 1( 39( ( I I

(,C (TEHITEH PS(CC026-06(A 720 N/ULC 103C 11.0 .711451 11 301 I I 33! 391 C ITEHITEH ICC024 05IA 720 H/ULC Iavi .0 2 31 Ii zl 3s( I I

( Ic ITEHITEK (CCOZC-05(A.720-N/ULC (avz .0 z( 24( I I I

-I c ITEHITEH ICC024-05IA.720.H/ULC (AV3 .0 ~ 91 IP 2( 261 I I I 34( 411 c ITEHITEH (ccozc-os(a-rzo-N/ULc Iav1 .0 1 ~ 1( IP 21 271 I I I (C (TEH(TEH ICC024-05IA-720 N/ULC Iav3 .D .S( z( 231 I I I I c ITEHITEH ICCO 05(A 7? N/ULC (avC ~0 1.o( (P z( 261 I I I 351 411 c (TEKITEH (CC024 05(A 720 H/ULC (av1 .0 z.C( IP 21 351 I I I (C ITEHITEH ICC024 0 IA 72 H/ULC IAV2 .0 2( 27( I I I (C ITEHITEH ICC024 OSIA 720-H/ULC Iavs .0 F 71 IP 21 zc( I I I Ic (CC024.05(A.720-H/ULC IAV4 0 I

I 331 431 ITEKITEH c ITEM(TEN PSICC025 DSIA 720 N/ULC (avz

~

.0 31

.51 (P 21 z11 IP 2( 221 I

I

'I I I I

I (C ITEHITEH PSICC025-05IA-720-H/ULC (av3 .0 .5( IP zl 23( I I I I 351 431 c ITEHITEH Pslcc025-05(A-720-N/ULc IAV2 ~ 0 -91 IP 21 261 I I (C ITEHITEH PSICC025-05IA.720.N/ULC IAV3 .0 1.4( 21 291 I I ( (C (TEH(TEH PSICC025.05(A-720 H/ULC (AV4 .0 21 zrl I I 131 441 H ITECITEH ICC031 06(A 720 N/ULC IozK 50.4 .r(1481 11 291 I I 341 44( C ITEHITEH ICC025 05(A.720 N/ULC (av3 .0 .5( 31 231 I I 35( 441 C (TEH(TEH PSICC025 OS(A-720 H/ULC IAV2 .D z( 3o( I I I Ic ITEHITEH PS(CC025-05(A-720.N/ULC (av3 .0 1.S( z( 3o( I I (C ITEHITEK PSICC02 0 IA 720.H/ULC (avC .0 .8( I 2( zs( I I 23( CS( C ITEHITEH ICC020.04IA.720-H/ULC (AV3 .1 .6( 2( 24( I I 351 451 c ITEHITEH PSICC 25 IA 72 H/ULC IAV2 .0 1.91 2( 331 I I (C IT<<ITEH PS(CC025 05IA 720.N/ULC (av3 .0 .61 II 21 24( I I I c ITEHITEH PSICC025-05(A-720 H/ULC IAvr .0 .S( zl zzl I I 41 46( c ITEHITSH PS(CC026 06(A-720 N/ULC ITSH 28.4 ~ r(1sz( 11 241 I I 301 461 C (TEH(TEH ICCD20-04IA-720 H/ULC IAV1 .1 1.61 IP z( 3z( I I I

+ --.I---I. I I I I I

-I---I--. I-- I I -I-

CUHULATivE EXAHINAT10N REPORT PTN-3 OUTAGE  : 09/92 COHPONEHT S/0 C Page 2of2 DESCRiPTiON  : 20X TO 39X Date 11/13/92 Time : 9:00 AH

+

I I Extent I I 09/92 I N/A I (Rog(Col( Leg(Req(Tat/N ote( Reel Probe Location (Volts(Deg(ch X,(Diff( Location (Volts(Deg (ch X

'-I"-I.--I-- I. I I

I I" I I

(

I I I

(

---(---+

(

I I I C ITEHITEK ICC020-04IA 720.H/ULC IAV2 .1 32( I I I I C ITEHITEH (ccozo-04(a-720-H/ULC (av3 .1 9I I>>I zs( I I 41( 46I H ITECITEC (CH034-09(A-720.H/ULC I06H 5.8 .7(145( 3zl I I 30I 48I H ITECITEC PSICH018 04(A 720 SF/RH (avz .0 .8( (P 2( zsl I I I I H ITECITEC PslcH018 04(a-720-SF/RH (av3 .0 1.6( (P 2( 34( I I 35( 49( H (TEC(TEC PSICH030-07IA-720.H/ULC IAV4 .0 ~ sl I>>l I

( 43( 53( H ITECITEC ICH033-08(A-720.H/ULC (Osc 3.2 .4 I 135 I 1 I I I 391 54I (TEC(TEC (CK031-07(A-720.H/ULC lav3 .0 (P 2( zol I

( zzl 55( H ITECITEC SS(CH022.05(A-720.H/ULC (06H 2.2 .8(135( 39l I

( 26( 58( H ITECITEC PSICK IA 720 H/ULC (Avz .0 .6( IP zl zzl I I 33( 58( H (TEC(TEC PCICH032.08IA-720.H/ULC (06C 37.3 .5 I 149( 1 I 26( I I 30I 61I H ITECITEC is(cH022-05(a-720-H/Ui.c (Avz .0 .7( (P 2( I

( 32( 62( H ITECITEC PCICH032-08IA.720.H/ULC (av3 9.1 .4I145I 1I 30I I

( 3S( 62( H ITECITEC PCICH032-OSIA 720.H/ULC (AV3 11.9 .S(145( 30I I I 24( 63( H ITECITEC SC(CH023-05(A 720.SF/RH (AV2 ~ 0 .5( IP 2( 24( I I I I H ITECITEC SCICH023-05IA 720-SF/RH (av3 .0 4I I>>l Z3( I H ITEC(TEC PCICK009 02(A 720 SF/RH (06H 14.1 ~ 6(151( 1( as)

I 20( 64( H ITECITEC ICK014 03(A-720 H/ULC (01C 50.3 .7(15s( 24(

( 30( 64( H ITEC(TEC SCICK023.05(A-720-SF/RH (06H 2.3 .6I159I 11 Zo(

( 32( 64( H ITECITEC ICH032-08(A-720.H/ULC 102H -.6 .6(106(P 1(

f 38( 65( H (1'ECfTEC PS(CK032 08(A-720.H/ULC IAV2 .0 .4f IP 2( as(

I I I H ITECITEC SICH032 08(A 720 H/ULC (av3 .0 3I I>>l 21(

I I ( H (TEC(TEC PS(CK032-08(A 72 H/ULC IAV4 .0 7I I>>l 24(

( 38( 71( H (TEC(TEC PS(CH026 06(A 720.H/ULC (AV3 .1 ~ 7I I>>l z1(

( 35( 72f H ITECITEC PS(CH026.06(A-720 H/ULC IAV2 7.9 .5I138I 1I 35(

H ITECITEC PSICH026 06IA-720.H/ULC (06H 22.8 3 I 149( 1 I 27(

1( 76( C (Osclosc ICC004 01IA-700.SF/RH (ozc 4.8 1.3 f139( 35(

I 13( 84( H ITECITEC PSICH017-04(A-720.SF/RH (04H 40.4 .6 I 157 I 1 I 23(

sl s7( H (TEC(TEC PS(CH011-02(A 720.M/ULC I02H 15.4 I .5I156I 1I 20(

3( 88( H I06CI06C PCICH007-01IA-680-SF/RH IBAH 19.9 .4(150( 1( 28I I

+." I- I -I --I-- -- I-.--- I-. I--- I I I

-I--- --- ---+

Number of RECORDS Selected from Current Outage 73 Nunber of TUBES Selected from Current Outage: 51

I Turkey Point Unit 3 1992 Refueling Outage Form NIS-2 Owners'ata Report of Repairs and Replacements

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER 8 LIGHT Date NOVEMBER 14, 1991

1. Owner Nemo P.O. BOX 029100 MIAMI FL 33152 Sheet of Address Plant TURKEY POINT Unit CWO: 500661, MPIL: 91-454M, MPIL 91-455M P.O. BOX 3088 FLORIDA CITY FL'33034 MPIL: 91-456M NCR-N-91<778 Address Repair Organization p.o. Ne., Jeb No., otc.
3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A Address

4. Identification of System Quality Group B
5. (a) Applicable Construction Code B31 19 5 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Manufacturer National Other epaired Name of Board Year Replaced Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

Est.

CHECK VALVE N/A N/A N/A 3-298 A REPLACED NO 1970 ROCKWELL N/A N/A 3-298A 1989 REPLACEME NO CHECK VALVE INTER.

EST.

CHECK VALVE N/A N/A N/A 3-298 B REPLACED NO 1970 ROCKWELL REPLACEME CHECK VALVE N/A N/A 3-298 B 1989 NO INTER.,

EST.

CHECK VALVE N/A N/A N/A 3-298 C REPLACED NO 1970 ROCKWELL 3-298 C REPLACEMEN NO CHECK VALVE N/A N/A 1989 INTER.

REPLACED CHECK VALVES 3-298A, 3-298B, 3-298C AND ASSOCIATED PIPING.

7. Description of Work
8. Tests Conducted: Hydrostatic XX Pneumatic Nominal Operating Pressure Other 3420 psl Test Temp. AMBIENT Degree.s F Pressure NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

91-066-3

Page 2 of 2 FORM NlS-2 (Back)

9. Remarks Examinations performed by FPL Construction Quality Control personnel.

Applicable Manulacturer's Data Reports to be attached ALLWELDING WAS PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUALAND SITE PROCEDURES.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement N/A Type Code Symbol Stamp Certificate of Authorization No. N/A Expiration Date N/A Signed Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed. by Arkwri ht Mutual Insurance Com an of N ood MA hav i cted the corpponents de~sribed in this Owner's Report during the perio to r , and state that to the best o y knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual System Commissions I pectors Signature National Board, State, Province, and Endorsements I'at 1 9~7

Page 1 of 2 FORM NIS 2 OWNER'S REPORT FOR RFPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER 8c LIGHT Date November 22. 1991 Name P.O. BOX 029100. MIAMI. FL 33102 Sheet I of Address TURKEY POINT

2. Plant Unit P.O. BOX 3088, FLORIDA CITY, FL 33034 P.Oe¹ B90950-90238 NCR¹ N-91-0208 Address Raper organization p.a. No.. Jotg No. etc.
3. Work Performed by FLORIDA POWER 8r LIGHT Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. BOX 3088, FLORIDA CITY. FL 33034 N/A Expiration Date Address
4. Identification of System Steam Generator Blowdown System Quality Group 5, (a) Applicable Construction Code ANSI B31 1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition. Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASM'ode National Repaired, Name of Name of Manufacturer Other Year Stamped Board Identification Replaced, Component Manufacturer Serial No. Built (Yes or No. or Replacement No) hiechanical Pacific Shock Scientific 244 15A N/A 3-1034 1983 Replaced Yes Arrestor hiechanical Pacific Shock Scientific 24429 N/A 3-1034 1983 Replacement Yes Arrestor 7 Description of Work RePI aced snubber tag¹ 3- 1 034 due to snubber locking uP in tension during handstroking frozen).
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psl Test Temp Degree's F N/A NOTE: Supplemental sheets in form of lists. sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 91-075-3

Page 2 of 2 FORM HIS 2 (Back) hiechanical connection. No welding performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report ore correct and this P a conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization o N/A N/A Fxpiration Dote Signed Date , 19%i Owner or 0 ner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arlcwri ht hiutual Insurance Com an of Norwood. hIA.

have inspected the components described in this Owner's Report during the period to A ril 1991 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory hiutual System Commissions 0230 N I nspector's Signature National Board, State. Province. and Endcrsements Da ~19 ~i

Page1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER 8 LIGHT DECEMBER 5, 1991

1. Otrrner Date P.O. BOX 029100 MIAMI FL 33152 Sheet of Address Plant TURK POINT Unit Name CWO: 300347 PC/M 90-306 P.O. BOX 3088 FLORIDA CITY FL33034 MPIL 90-241 M Address Repair Organization p.O. No. Job No., etc.

~

3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A Address

4. Identification of System COMPONENT COOUNG WATER Quality Group C
5. (a) Applicable Construction Code 19 55 Edition, N Addenda, N Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National Repaired, QSME Name of Name of Manufacturer Board Other Year Replaced, Manufacturer Serial No. Identification Built Stamped Component No. or Replacement (Yes or No)

EST.

CCW PIPING N/A N/A SR-1 38 REPLACEMENT NO 1970 EST.

CCW PIPING N/A N/A N/A SR-169 REPLACEMENT 1970 EST.

CCW PIPING N/A N/A N/A SR-172 REPLACEMENT 1970 EST.

CCW PIPING N/A N/A N/A SR-297 REPLACEMENT NO 1970 EST.

CCW PIPING N/A N/A N/A SR-304 REPLACEMENT 1970 MODIFIED SUPPORTS SR-138, SR-169, SR-172. SR-297 AND SR-304 TO MEET DESIGN.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

91-079-3

I Page 2 of 2 FORM NIS-2 (Back)

9. Remarks Examinations performed by FPL Construction Quality Control personnel.

Applicable Manufacturer's Data Reports to be attached ALLWELDING WAS PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUALAND SITE PROCEDURES.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of No d MA have 'pected the mponents described in this Owner's Report during the perio z5' and state that to the best of knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual System i'/

s Signature Commissions National Board, State, Province, and Endorsements

Page 1 of 3 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT Date DECEMBER 18, 1991 Owner Name P.O, BOX 029100 MIAMI FL 33152 Sheet of Addross

2. Plant TURKEY POINT Unit CWO: 300132 PC/M: 87-025 P.O. BOX 3088 FLORIDA CITY FL 33034 P.S.90-184 90-185 90-187 90-186 Address Repair Organization P.O. No. Job No., otc.

~

3. Work Performed by Type Code Symbol Stamp Name Authorization No.

RI I Expiration Date N/A Addross

4. Identification of System COMPONENT COOLING WATER Quality Group C
5. (a) Applicable Construction Code B 19 5 Edition, N Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Manufacturer National Other e paired>> QSoMdeE Name of Name of Board Year Replaced, Stamped Component Manufacturer Serial No. No. Identification or Replacement (Yes or No).

NORMAL CTMT. Est.

N/A N/A N/A 3V1 A REPLACED NOd COOLER 1970 NORMAL CTMT. ECODYNE 40783-1 5665 3V1A 1989 REPLACEMENT COOLER MRM, INC.

NORMAL CTMT. Est.

N/A N/A N/A 3V1 B REPLACED NO COOLER 1970 NORMAL CTMT. ECODYNE 40783-2 5666 3V1B 1989 REPLACEMENT NO COOLER MRM, INC.

NORMAL CTMT. Est.

N/A N/A N/A 3V1C REPLACED NO:

COOLER 1970 NO'ORMAL NORMAL CTMT. ECODYNE 40783-B 5668 3V1C 1989 REPLACEMENT NO COOLER MIM, INC.

CTMT. Est.

N/A N/A 3V1D REPLACED NO COOLER 1970 REPLACED TUBE BUNDLES IN NCC 3V1A, 3V1 B, 3V1 C AND 3V1D. MODIFIED EXISTING

7. Description of Work CCW PIPING TO FACILITATEINSTALLATIONOF NCC 3V1C TUBE BUNDLE.
g. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Ottter Pressure 70 psi Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

91-080-3

Paye 2 of/3 AVZltct/rIt FORM NIS-2 (Back)

9. Remarks Examinations performed by FPL Construction Quality Control personnel.

Applicable Manufacturer's Data Reports to be attached ALLWELDING WAS PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUALAND SITE PROCEDURES.

TUBE BUNDLES WERE BUILTTO ASME Vill 1986 EDITION, A87 ADDENDA 2051 CODE CASE CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code.Section XI. repair or replacement N/A Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No.

Signed Date l~ ~~,19</

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Count Florida and employed by Arkwri ht Mutual Insurance Com an of No d MA have 'cted the mponengts ascribed in this Otvner's Report during the period to , and state that to the best of knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual System

~~

Commissions insp r's Signature National Board, State, Province, and Endorsemen D t <9~x

5 Page/of 3 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER 8 LIGHT DECEMBER 18, 1991 OtNner Date Name PO 0 IA I Sheet of Address

2. Plant POI Unit Name CWO: 300132 PC/M: 87-025 P.O. BOX 3088 FLORIDA CITY FL 33034 P.S.90-184 90-185 90-187 90-186 Address Repair Ortt anization P.O. No., Job No., etc.
3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A Address COMPONENT COOLING WATER

4. Identification of System
5. (a) Applicable Construction Code B31. 19 55 Edition, NA Addenda, N Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National Repaired Code Name of Name of Manufacturer Other Year Board Identification Replaced, Stamped Component Manufacturer Serial No. Built No. r Replacement (Yes or NORMAL CTMT. ECODYNE 40783-3 5667 3V1D 1989 EPLACEME NO COOLER MRM, INC.

91-080-3

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POlYER 8c LIGHT December 19, 1991 Date Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT Unit Name P.O. BOX 3088. FLORIDA CITY, FL 33034 PWO: 2492 WAss 910914215546 Address Repas Craanizatiott P.O. No.. Job No. etc.

3. Work Performed by FLORIDA POWER 8c LIGHT Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. BOX 3088, FLORIDA CITY, FL 33034 Expiration Dote N/A Address
4. Identification of System Reactor Vessel Quality Group
5. (a) Applicable Construction Code ASME S<< III 19 65 Edition, N/A Addenda, N/A Code Case Addenda (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980. Edition. Winter 1981
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Other Stamped Board Replaced Component Manufacturer Serial No. Identification B lit (Yes or No. or Replacement No)

Reactor Babcock Pressure lk 610-0116 N-160 3T237 1969 Repl acement yes Vessel Wilcox

7. Description of Work RePlaced male flange on S.E. Conoseal assembly.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure 2280 psl Test Temp gM Degree's F

'RCS Overpressure Test performed in accordance with OP 1004.1 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 91-081-3

Page 2 of 2 FORM NIS 2 (Back) 9 Remarks hlechanical connection.No welding performed Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report ore correct and this P conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A N/A N/A Certificate of Authori o ion No. Expiration Date Signe Dote I~ 19 1/

Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECllON I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by I

Arkwri ht hfutual Insurance Com an of Norwood, NA.

September 15. 1991 have inspected the components described in this Owner's Report during the period to Se tember 22. 1991 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective meosures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory hiutual System Commissions 0230 N I nspector's Signature National Board. State. Province, and fndorsements 19

.-i F~it 'ir=-7 OWNER'S R-7'ORT QR RE, AIRS OR REPLAC tAQN!$

As Reauirea by the Provisions of the ASME Code Section XI FLORIDA POWER 8c LIGHT Dcte January 9. 1992

~ odner

,No isle P.O. BOX 029100. MIAMI. FL 33102 oncet seeress otcrl TURKEY POINT Unit Ndme P.O. BOX 3088. FLORIDA CITY. FL 33034 PWO: 2542 WAss 911114112950 Address eteoor Crqonizoiton P,O. No.. doo No. etc.

p(ark p er formed by FLORIDA POWER 8c LIGHT Type Code Symbol Stamp N/A Name iV/A Authorization No.

P.O. BOX 3088. FLORIDA CITY. FL 33034 Expiration Date iV/A Address

-'. laentificauon of System Intake Cooling Water Quality Group s

5. (a) APPliCabie COnStruCtian COde ANSI B31 1 19 55 EditiOn. N/A Addenaa, N/A r.'oae Case
b) Aoplicabie Edition of Section XI Utilized for Repairs or Replacements 1980. Eaition. Winter !981 Addenda
o. !Centification Of Comoonents Repairea cr Replaced ana Replacement Components ASM/

Mcr ufccturer National Other Year R ep air ed. Code Name of Nome of Stcntoec Se"ci No. Boara !dent'ification Built Replaced.

Component Manufacturer No. or Replacement (YdS Or No)

Gate Valve Jenkins Valve V/A N/A 3-50-367 1989 Replaced e I

No Gate Valve Jenkins Valve N/A TV/A 3-50-367 1991 Replacement No 7 Description of Wor!t Replaced valve at tag location 3-50-367 due to excessive seat, leakage.

f

8. Tests Conaucted; Hydrostatic,pneumaticL I Nominal Operottna pressure thher Pressure psl Test Temp TS pearse's P NOTE: Supplemental sheets in form of lists. sketches. cr drawings may be used, provided (1) size is 8 1/2 "r.,

x '1 lin.. (2) information in items 1 througn 6 on this report is includea on each sheet. ana (3) each sneet Ts numberea ona the number of sheets is recorded at the top of this form. 92-001-3

e Mechanical connection, No weldinn f' rned.

4ooncaoie uonvfoctwer's bate aeoorts to oe attacnea CERTIFICATE OF COMPUANCE We certify tnat the statements made in the report cre correct and this conforn's repas'r reolacement to the rules of the ASME Code.Section XI.

Type Code Symbol Stamp N/A Certificate of Auth,iza n No.

N/A N/A Expiration Date Signea- Date Owner or Owner's Designee, Title I

CERTIFICATE OF INSERVICE INSPECTION I. the unaersignea. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors ond the State or Province of Dade County. Florida and employed by Arlnrri ht Mutual insurance Com an of Norsrood, MA.

have inspected the components described in this Owner's Report during the period November 1991 to December 1991 , and state that to the best of my knowledge and be!ief.

the Owner hOS perfarmed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code. Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or complied. concerning the examinations and corrective meosures described in this Owners Report. Furthermore.:

l neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or o loss of any kind arising from or connected with the inspection.

Factory Mutual System Commissions 8$ 3Q (N) 1) actor's Signature Notianai Boara, State. Province, ana Enaorsen'ents

Poge 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT January 13, Name 199+'heet P.O. BOX 029100, MIAMI FL 33102

~ 1 of r Address TURKEY POINT Unit Name P.O. BOX 3000, FLORIDA CITY, FL 33034 PWO: 2743 NCR¹ N-90-0001 CNR¹ 90-3-0011 Address Repas Organization P.O. No.. Job No. etc.

3 'Work Pe formed by FLORIDA POWER & LIGHT Type Code Symbol Stamp N/A Nome Authorization No. N/A P.O. BOX 3000, FLORIDA CITY, FL 33034 N/A Expiration Date Address

4. Identification of System Feedwater Quality Group B
5. (a) Applicable Construction Code ANSI B31 1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Repaired, Code Other Year Stamped Component Board Replaced, Manufacturer Serial No. Identification Built (Yes or No. or Replacement No)

Piping FW N/A N/A N/A 14"-FWB-2303-10 1970 Repaired No 7 D r t n of 'Work Repaired, by buffing, one linear indication adjacent to FW¹ 14"-FWB-2303- 10.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure -

Other r

0 Pressure psl Test Temp Oegrer/s N/A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 92-002-3

Page 2 of 2 FORM NIS-2 (BCICk)

9. Remarks No welding Performed.

Applicable Monufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE We certify that the statements made irt the report are correct and this repair conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No N/A N/A Expiration Date Signed Date , 19%A Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arlcwri ht Mutual Insurance Com any of Norwood, MA.

hove inspected the components described in this Owner's Report during the period to March 26. 1990 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual System Commissions 0230 N I spector's Signature Notional Board. State. Province. ond Endcrsements

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER 8c LIGHT Dote January 13. 199~

Name P.O. BOX 029100, hiIAhiI, FL 33102 Sheet 1 of 1 Address TURKEY POINT Unit Name P.O. BOX 3088, FLORIDA CITY. FL 33034 PWO: 2740 NCR¹ N-90-0080 CNR¹ 90-3-0008 Address Raper organization P.O. No.. Job No. etc.

3 Work Per fo med by FLORIDA POWER 8c LIGHT Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/A Expiration Date Address

4. Identification of System Feedwater Quality Group
5. (a) Applicable Construction Code ANSI B31 1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Repaired, Code Other Year Stamped Component Manufacturer Serial No. Board Identification Replaced.

Built (Yes or No. or Replacement No)

Piping FW N/A N/A N/A 14 FWA 230 1 2 1A Repaired No 7 Descri tion of 'Work RePaired, by buffing, four linear indications adjacent to FW¹ 14"-FWA-230 1-2 1A.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure ps l Test Temp Degree's p N/A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered ond the number of sheets is recorded at the top of this form. 92-003-3

Page 2 of 2 FORM HIS 2 (Back)

9. Remarks No welding Performed.

Applicoble Manufacturer's Ooto Reports to be attached CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this repair conforms repair ar replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stomp N/A Certificate of Authoriza ion No. N/A N/A Expiration Date Signe Dote Owner or Owner esignee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arlcwri ht Mutual Insurance Com an of Norw ood. MA.

have inspected the components described in this Owner's Report during the period to March 26. 1990 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any worranty, expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual System Commissions 8230 N I fnspector's Signature Notional Board. State. Province, and Endorsernents

@ed

Page 1 of 2 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT January 21, 19gZ~s Name P.O. BOX 029100, MIAIIII,FL 33102 Sheet 1 of 1 Address TURKEY POINT Unit Name P.O. BOX 3088, FLORIDA CITY. FL 33034 PWO: 2548 WA¹91 1206073226 Address Repa'r organization P.o. No.. Job No. eta.

3. Work Perfprmed by FLORIDA POWER & LIGHT Type Code Symbol Stamp N/A Name N/A Authorization No.

P.O. BOX 3088, FLORIDA CITY, FL 33034 Expiration Date N/A Address

4. Identification of System Intake Cooling Water Quality Group
5. (a) Applicable Construction Code ANSI B31 I 19 55 Edition, N/A Addendo, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Notional Repaired, Code Name of Name of Manufacturer Other ear Stomped Board Identification Built Rep I aced.

Component Manufacturer Serial No. (Yes or No. or Replacement No)

EST.

Gate Valve N/A N/A N/A 3-50-377 1970 Replaced No Gate Valve Jenkins N/A N/A 3-50-377 1991 Replacement No 7 pescriptipn pf 'Work Replaced valve at tag location 3-50-377 due to excessive seat leakage.

Hydrostatic Pneumatic Nominal Operating Pressure X Other

8. Tests Conducted:

Pressure ps l Test Temp gg Degree's r NOTE: Supplemental sheets in form of lists. sketches, or drawings moy be used, provided (1) size is 8 1/2 in.

~ ~

X 11in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered ond the number of sheets is recorded at the top of this form. 92-006-3

Page 2 of 2 FORM NIS 2 (Back) 9 Remarks hiechanical connection,No welding performed Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this p conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate Authorizati No N/A N/A Expiration Date Signed Date 19 9~

Owner or Owner'esignee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County. Florida and employed by Aricwri ht hiutual Insurance Com an of Norwood, hfA.

have inspected the components described in this Owner's Report during the period to December 16, 1991 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory hfutual System Commissions 0230 N I Inspector's Signature National Board. State. Province. and Endorsements 19

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER 8c LIGHT Date January 21. 199+'~

Name P.O. BOX 029100, hfIAhfi, FL 33102 Sheet 1 of Address TURKEY POINT 3 Unit Name P.O. BOX 3088, FLORIDA CITY. FL 33034 PWO: 9900 WAts 911028140919 Address Repar Organization P.o. No.. Jab No. etc.

3 Work Performed by FLORIDA POWER Ik LIGHT Type Code Symbol Stamp Name Authorization No. N/A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/A Expiration Date Address

4. Identification of System Intake Cooling Water Quality Group
5. (a) Applicable Construction Code ANSI B31 1 19 55 Edition, N/A Addenda, N/A Code Cose (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replocement Components ASME Name of Name of National Repaired, Code Manufacturer Other Year Stomped Manufacturer Board Identification Replaced, Component Serial No. Built (Yes or No. or Replacement No)

EST.

Gate Valve N/A N/A N/A 3-50-354 1970 Replaced No Gate Valve Jenkins N/A N/A 3-50-354 1991 Replacement No 7 Descriptjpn pf Wprk Replaced valve at tag location 3-50-354 due to excessive seat leakage.

t 8. Tests Conducted: Hydrostatic Pneumotic Nominal Operating Pressure X Other Pressure ps l Test Temp I Degree's F NOTE: Supplemental sheets in formiof lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 92-004-3

Page 2 of 2 FORM NIS 2 (Back)

Iechanical connection, No welding performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this p conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A N/A N/A Certific Aut rizo n No. Expiration Date Date , 19 Signed Owner or owner's esignee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Aricwri ht hfutual Insurance Com an of Norwood. hfA.

November 04. 1991 have inspected the components described in this Owner's Report during the period to December 15, 1991 , and state that to the best of my knowledge and belief.

the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any worranty, expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory hfutual System Commissions 8230 N I nspector's Signature National Board, State, Province. and Endorsefnents

Page 1 of 2 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER fk LIGHT January 21, 2,~

199~

Nome P.O. BOX 029100, hIIAhti. FL 33102 Sheet I of Address TURKEY POINT .3 Unit Nome P.O. BOX 3088, FLORIDA CITY, FL 33034 PWO: 9900 WAst 911028141649 Repoir Crgonizotion P.O. No., Job No. etc.

Work Performed by FLORIDA POWER 8c LIGHT Type Code Symbol Stamp N/A Nome Authorization No. N/A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/A Expiration Dote Address

4. Identification of System Intake Cooling Water Quality Group
5. (a) Applicable Construction Code ANSI B31.1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Other Repaired, Code Name of Name of Manufacturer Year Board Identification Replaced, Stamped Component Manufacturer Seriol No. Built (Yes or No. or Replacement No)

EST.

Gate Valve N/A N/A N/A 3-50-357 1970 Replaced No Gate Valve Jenkins N/A N/A 3-50-357 1991 Replacement No 7 Description of 'Work Replaced valve at. tag location 3-50-357 due to excessive seat leakage.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other Pressure psi Test Tem P M De 9 ree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used. provided (1) size is 8 1/2 in.

X 11in. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is

~

numbered and the number of sheets is recorded at the top of this form. 92-005-3

Page 2 of 2 FORM NIS-2 (Back)

9. Remarks hfechanical connection'. No welding performed.

Applicable Manufacturer's Ooto Reports to be attached CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this P conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A N/A N/A Certifica uthori tion o. Expiration Date Signed Owner or Owner's Oesianee. title Date I 4P, 19 cr CERTIFICATE OF INSEAVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dado County, Florida and employed by Aricwri ht hfutual Insurance Com an of Norwood. IIA.

have inspected the components described in this Owner's Report during the period to December 15. 1991 , and state that to the best of my knowledge and belief.

the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or o loss of any kind arising from or connected with the inspection.

Factory hiutual System Commissions 8230 N I Inspector's Signature Notional Board, State, Province, and Endcrsements

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLO ID POWER 8 LIGHT Date MARCH 25, 1992 OtNner PO BO 029100 MIAMI FL33152 Sheet of Address

2. Plant TU K POINT Unit Name CWO: 300202 PC/M: 90-471 P.O. BOX3088 FLORIDA CITY FL'33034 MPIL NO. 91-515M Address Repen Organtsation P.O. No., Job No., etc.
3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A

4. Identification of System COMPONENT COOUNG WATER Quality Group C 19 Edition, N/A Addenda, N/A Code Case
5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National Repaired, /ISME Name of Name of Manufacturer Board Other Year Replaced, Component Manufacturer Serial No. Identification Built Stamped No. or Replacement ( esor No)

Est.

CCW SURGE TANK N/A 3T218 REPLACEME NO 1970 MODIFIED CCW SURGE TANKSUPPORT STRUCTURE TO MEET DESIGN.

7. Description of Work
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other N/A Pressure psi Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

92-007-3

Page 2 of 2 ~

FORM HIS-2 (Back)

9. Remarks Examinations performed by FPI Construction Quality Control personnel.

Applicable Manufacturer's Data Reports to be attached ALLWELDING WAS PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUALAND SITE PROCEDURES.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signe t cr,'ubi c~ Date ,~g 5'x ner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norw d MA have inspected the components described in this Owner's Report during the period /

to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage r a loss of any kind arising from or connected with this inspection.

Factory Mutual System Commissions In tor's S gnature National Board, State, Province, and Endorsements

@~DE i9 V'

Page1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FL ID POWE & IGHT Date April 8, 1992 Owner P.O BO 0 9100 MIAMI F 3315 Sheet of Address 2 Piant TURK OINT Unit Name CWO: 300339, PC/M: 90-272, MPIL: 91-521M P.O. BOX3088 FLORIDA CITY FL33034 NCR-C4219-875 C4271-875 C-0613-875 Addmss Repair Organizraion P.O. No. Job No., etc.

~

3. Work Performed by Type Code Symbol Stamp Authorization No.

Expiration Date N/A

4. Identification of System SAFETY INJECTION Quality Group B
5. (a) Applicable Construction Code 19 5 Edition, N/ Addenda, N Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Manufacturer NaVonal Other Repaired, Code Name of Name of Board Year Replaced, Component Manufacturer Serial No. No. Identification Built or Replacement Siped No)

Est.

PIPING Sl N/A N/A N/A H-3 REPLACEME 1970 Est.

PIPING SI H-10 1970 REPLACEMENT NO Est.

PIPING Sl N/A N/A H-18 REPLACEMENT 1970 Est.

PIPING SI N/A N/A N/A H-19 1970 REPLACEMENT Est.

PIPING Sl N/A H-24 REPLACEMENT NO 1970 MODIFIED SUPPORTS H-3, H-10, H-18, H-19 AND H-24 TO RESTORE TO ORIGINAL DESIGN.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other N/A Pressure psi Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

92-008-3

Page'2of2 FORM N(S-2 (Back)

Remarks Examinations performed by FPL Construction Quality Control personnel.

Applicable Manufacturer's Data Reports to be attached ALLWELDING WAS PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUALAND SITE PROCEDURES.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificat uthorization No. N/ Expiration Date N/A Signed Date Owner o ner's Desi nee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood M have ins ted the components described in this Owner's Report during the period ~c2-to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual System Commissions tor's Signature National Board, State, Province, and Endorsements 197~

Page 1 of2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLO IDA POW & LIGHT Date June 10, 1992 Ohrner P.O. BOX 029100 MIAMI F 33152 Sheet of Address 2 Plant TURK POINT Unit Name CWO: 500832 PC/M: 9lM14 P.O. BOX 3088 FLORIDA CITY FL33034 MPIL NO. 92%49M Address Repair Ortt anization P.O. No. Job No., otc.

~

3. Work Performed by Type Code Symbol Stamp Name Authorization No Expiration Date N/A Address
4. Identification of System SAFETY INJECTION Quality Group B 1 1 19 55 Edition, N Addenda, N/A Code Case
5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired, 'P Board Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

Est.

PIPING SIS N/A N/A N/A SR-160 REPLACED NO 1970 PIPING SIS N/A N/A N/A SR-160 1992 REPLACEME NO REPLACED SUPPORT SR-160 TO MEET DESIGN.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other N/A Pressure psi Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

92-009-3

Page2of2 FORM NlS-2 (Back)

9. Remarks Examinations performed by FPL Construction Quality Control personnel.

Appiicabie Manufacturer's Data Reports to be attached ALLWELDING WAS PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUALAND SITE PROCEDURES.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Owner or OwneVs Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to JUNE 1992 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI ~

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations arid corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arisin from or connected with this inspection.

Factory Mutual System Commissions 8230 ns r's Signature National Board, State, Province, and Endorsements Date $ 9 FZ

Page 1 of 2 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT pate August 7s 1992 Name P.O. BOX 029100, hiIAhil, FL 33102 Sheet 1 of Address TURKEY POINT Unit Name P.O. BOX 3008, FLORIDA CITY, FL 33034 PWO: 1410 WA¹ 920416054031 Address Repa'r Crganizatian P.O, Na.. Jab Na. etc.

Work Performed by FLORIDA POWER & LIGHT Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. BOX 3000. FLORIDA CITY, FL 33034 N/A Exp ir ation Da te Address

4. Identification of System Intake Cooling Water Quality Group
5. (a) Applicable Construction Code ANSI B31 I 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufactur er Other Year Stomped Manufacturer Board Identification Replaced, Component Serial No. Built (Yes or No. or Replacement No)

Check Valve hfission Vlv 10635 N/A 3-50-331 Replaced No Check Valve hfission Vlv 41195 N/A 3-50-331 Unk. Replacement No 7 Description of Work Replaced valve at tag location 3-50-33 1 due to excessive seat leakage.

t

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other Pressure psi Test Temp gg Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 92-011-3

Page 2 of 2 FORM NIS-2 (Back) g Remarks Mechanical connection, no welding performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this p conforms repair or replacement to the rules of the ASME Code.Section XI.

Type Code Symbol Stamp N/A Certificate of Authorize n No.

N/A N/A Expiration Date Signe Date P /

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the Notional Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Count, Florida and employed by Arlcwri ht Mutual Insurance Com an of Norwood. MA.

have inspected the components described in this Owner's Report during the period to ~ and state that to the best of my knowledge and belief, the Owner has performed examinotions and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied. concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage a loss of any kind arising from or connected with the inspection.

Factory Mutual System Commissions 0230 N I inspector's Signoture National Board, State, Province. and Endorsements

Page1 of2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI F RI POW R & IGH Date JULY 13, 1992 Owner P.O. BOX 029100 MIAMI FL 33152 Sheet 1 of 2 Plant TURK POINT Unit Name CWO: 500871 PC/M: 92-076 P.O. BOX3088 FLORIDA CITY FL'33034 NCR-N-92-0131 MPIL: 92-084M Address Repair Organization P.O. No. Job No., etc.

~

3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A

4. Identification of System COMPONENT COOLING WATER Quality Group C B31 19 5 Edition, NA Addenda, N/A Code Case
5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Other Repaired, Code Name of Name of Manufacturer Board Year Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

Est.

SUPPORT N/A N/A H-1 REPAIRED 1970 A SHIM WAS ADDED TO SUPPORT H-1 ON THE COMPONENT COOLING WATER

7. Description of Work SYSTEM TO PROVIDE THE PROPER CLEARANCE.
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other N/A Pressure psl Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

92-010-3

Page2ofk FORM HIS-2 (Back)

9. Remarks Examinations performed by FPL Construction Quality Control personnel.

Applicable Manufacturer's Data Reports to be attached ALLWELDING WAS PERFORMED IN ACCORDANCE WITH THE FPL WELD CONTROL MANUALAND SITE PROCEDURES.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR conforms to the rules of the ASME Code,Section XI. repair or replacement N/A Type Code Symbol Stamp N/A Expiration Date N/A Certific of uthorization No Signed Date Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to JULY. 1992 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage r a loss of any kind arising from or connected with this inspection.

Factory Mutual System Commissions Natfonal Board, State, Province, and Endorsemen

'Da / 19 FW

Page 1 of 2 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER L LIGHT AUGUSF 13, 1992 Name P.O. BOX 029100, hiIAhfl, FL 33102 Sheet 1 of 1 Address TURKEY POINT 3 Unit Name P.O. BOX 3000, FLORIDA CITY, FL 33034 PWO: 1270 WA¹ 920323222630 Address Repa'r organization P.O. No.. Job No. ete.

Work Performed by FLORIDA POWER 8e LIGHT Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. BOX 3000, FLORIDA CITY. FL 33034 N/A Expiration Date Address

4. Identification of System Intake Cooling Water Quality Group
5. (a) Applicable Construction Code ANSI B31 1 19 55 Edition, N/A Addenda. N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980. Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Manufacturer National Other Repaired, Code Name of Name of Year Stamped Serial No. Board Identification Replaced, Component Manufacturer B lt (Yes or No. or Replacement No)

Exp. Joint Unknown Unknown N/A XJ-3-1407 .Unk. Replaced No Exp. Joint Garlock 1-2174 N/A XJ-3-1407 Unk. Replacement No

7. Description of Work Replaced expansion 3oint XJ-3-1407
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure p st Test Temp rg Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used. provided (1) size is 8 1/2 in.

~

X 11in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is

~

numbered and the number of sheets is recorded at the top of this form. 92-012-3

FORM HIS 2 (Back)

Page 2 of 2~

9 Remarks Mechanical connection,no welding perfo'~J Applicoble Manu(acturer's Data Reports to be attached CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this P conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization o. N/A N/A Expiration Date Signe Owner or Owner's Designee. Tit e Date 8" /I') ~ 19 ~~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Count, Florida and employed by Arlcwri ht Mutual Insurance Com an of Norwood, MA.

have inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising m or connected with the inspection.

Factory Mutual System Commissions 0230 N I In s Signature Nationol Board, State, Province, and Endorsernents

Page1 of2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Owner F 0 I A POW & I HT Date P,O 0 00 MIAMI F 33 52 Sheet 2 Plant TURKEY POINT Unit 3 CWO 500829 NCR 722-86 P.O. BOX3088 FLORIDA CITY FL33034 MPIL 92-086M Address Repair Organization P.O. No., Job No., etc.

3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A

4. Identification of System Quality Group C 19 55 Edition, NA Addenda, NA Code Case
5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National Other Repaired Name of Name of Manufacturer Board Year Repia~, StCaomdpeed Component Manufacturer Serial No. No. Identification or Replacement (Yes or No)

N/A N/A est. REPLACED SUPPORT N/A N/A 1970 NO SUPPORT BERGEN- N/A N/A N/A 1992 EPLACEMENT 'O REPLACED 4n DIA. PIPE U-BOLT

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other X Pressure ~NA Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

92-013-3

Page2of2 FORM HIS-2 (Back)

9. Remarks EXAMINATIONS PERFORMED BY FPL CONSTRUCTION QUALITY Applicable Manufacturer's Oata Reports to be attached CONTROL PERSONNEL CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement N/A Type Code Symbol Stamp Certificate o uthorization No. N/A Expiration Date N/A Signed 0919 'o/r> / ~,19'r~

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norw d A have 'pect the components described in this Owner's Report during the period 4'

, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a toss of any kind arising from or connected with this inspection.

Factory Mutual System Commissions tor's Signature

+~

In National Board, State, Province, and Endorseme Da 19

> ~>

Page 1 of 2 FORM NIS-2 OlNNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner W 10/h/92 P.O. 100 MIAMI L 3 5 Sheet of
2. Plant Unit CN 500968. IL 92-123H, IL 92-128N P.O. BOX 3088 FLORIDA CITY FL 33034 V.O 92032066 ~ 870h2003 ~ 92032067 IKR 92-0167 Address Repair Or9aniza! ion P O. No., Job No., oto.
3. Work Performed by Type Code Symbol Stamp Authorization No.

Expiration Date N/A

4. Identification of System Quality Group
5. (a) Applicable Construction Code B31.1 19 55 Edition, N/A Addenda, N/A .Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components I Name of Component Name of Manufacturer Manufacturer Serial No.

798t h 5 790lh6 National Board No.

Other Identification 3-777 3-833 Built 1D7D 1979 Repaired, Replaced, orRepi c m'ent REPLACDKNT REPLACEN34T Stamped (Yes or No) 922583-2 3-83h EST 3"777 1970 . REPLACEtK.

E8T 1970"

4 ~ >",

EDT 3-83h 1970 II f WOg ALVE8 3 777 3 833 and 3 83h

8. Tests Conducted: Hydrostatic x Pneumatic Nominal Operating Pressure Other Pressure 165 psl Test Temp 6'~

87 'F13'-777 6 3-83h h

~

Degree'8 F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used; provided (1) size is 81/2 in.

X 11 ln., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is'-

numbered and the number of sheets is recorded at the top of this form.

Page 2 of FORM NlS-2 (8ack)

9. Remarks Appricable Manufacturer's Data Reports to be attached ALL VELOINO IN A/V FPL VELD CIX4TROL HAJUAL AM) GITE PROCEOUREG CERTIFiCATION OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp

'/~le ~

Certificate of Authorization No. Expiration Date

,19 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the Nationaf Soard of Boiler and Pressure Vessel-Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual insurance Com an of Norwood MA 7/29/92 have inspected the components described in this Owner's Report during the period BEGIN to , and state that to the best of my knowledge and belief,-

the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arisi from or connected with this inspection.

Factory Mutual System Commissions National Board, State, Province, and Endorsemenls D ~7 ~9~7

Page1of2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl 10/15/92 1 Owner F Rl AP WERI'HT Date P.O. BOX 029100 MIAMI F 315 Sheet of Unit 3

2. Plant CNO 500709 PC/M 91-199 P.O. BOX 3088 FLORIDA CITY FL'33034 IL 92-005M/VO 920rir1137 Address Repair orgaeaaiiaa p.o. No. Jeb No., ate.

~

3. Work Performed by Type Code Symbol Stamp Name Authorization No.

Expiration Date N/A Address Coolant

4. Idontification of System Quality Group A B31.1 19 55 Edition, N/A Addenda, N/A Code Case
5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Other Repaired, Code Name of Name of Manufacturer Board Year Replaced, Manufacturer Serial No. Identification Built Spam ped Component PATERSON No. or Replacement ( esor No)

EST SPRING HANGER NIA NIA NIA VS 16-12 1970 SERGEN 600501ri SR-F00 SPRING HENGER 6005013 NIA VS-16-12 1092 NO

7. Description of Work
8. Tests Conducted: Kydrostatlc Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet and the number of sheets is recorded at the top of this form.

is'umbered

Page2of2 FORM HIS-2 (Back)

9. Remarks Applicable Manufacturer's Data Reports to be attached hKCHANICAL CQWECTION - NO trELOINI PERFHBKD CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Signed Owner or Owner's Designee, Title Date + ~, 19 ~~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to 10/15/92 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual System Commissions s signature National Board, State, Province, and Endorsements 19~M

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner F P W I oCTaeER l8. 1002 P 0 OX 029100 MIAMI F 3315 Sheet of
2. Plant Unit CVD: 500830 i%A 88-078 MILs 02-08 IN P.O. BOX 3088 FLORIDA CITY FL33034 PC/Hs 80 She SAR N-02" 02l5 Address Repair Organization P.O. No.. Job No., eto.
3. Work Performed by Type Code Symbol Stamp Authorization No.

Expiration Date N/A Address 4 identmcatlon of System contsl~t 8 rs 8 st~ Quality Group

5. (a) Applicable Construction Code 19 Edition, N/ Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National Repaired, +SME Name of Name of Manufacturer Other Component Manufacturer Board Replaced, Serial No. No. IdentiTicatlon Built or Replacement No) st P IPE SUPPI%T N/A NIA N/A 3-8IH-h I 070 PIPE SUPPIXIT N/A NIA NIA 3-SIH-rl l Q02 REPLACHKNT REPLltcED PIPE sl&PART vELKKD BEAII ATTAcfoKNT Alki 5 I8 0 vEllKD EYE RDD 7 Descrj Uon of Work
8. Tests Conducted: HydrostaUc Pneumatic Nominal Operating Pressure Other N/A N/A Pressure psl Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

gz -o/B-B

Page 2of 2 FORM HIS-2 (Back)

9. Remarks Exoalnst loni porCor9Nad by FPL Ccnatructlon Quollty Control poreonnol Applicablo Manulacturor's Oats Roports to bo attached ALL VELOIlaI VAS PERFtÃJ%93 IN ACCOROANCE VITH THE FPL VELO CttriROL NANUAL ANO SITE PROCEOORES CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code, Section Xl. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date Signed Date 1 I 0 17

, 19 ~z Owner or Owner's Designee, Title

~ 1 4p CERlIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issuedby the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of- Dade Coun Florida and employed by Alkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period lo 10-10-02 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage o a loss of any kind aris'rom or connected with this inspection.

Factory Mutual System Commissions ns poc 's Signature National Board, Stato, Province, and Endorsomonts 19

Page1 of 2 FORM NlS-2 OWNER'S REPORT FOR REPAtRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl F October 19. 1992

1. Owner Date 1 1 P.O. 100 MIAMI F 15 sheer or Addreaa
2. Plant Unit CKO 500842 XO 91058444 P.O. BOX 3088 FLORIDA CITY FL 33034 KCR N-89-0339 NP IL 92-126H Addreaa Repair Organcaiion P.O. No., Job No., etc.
3. Work Perlormed by Type Code Symbol Stamp Authorization No.

Expiration Date N/A Addreaa

4. IdentiTicatlon ol System Quality Group
5. (a) Applicable Construction Code 19 55 Edition, NIA Addenda N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Board Other Repaired, Replaced,

$SME Component Manufacturer Serial No. No. identification BuiK or Rephcement No)

EST Spring Hanger N/A /A N/A VSID-13 1970 Replaced 52760 Spring Hanger Bergen Patterson 52719 N/A SR-308 1992 Re 1acemnt EST Spring Hanger N/A /A N/A VSID-13 1970 Replaced 52793 Spring Hanger Bergen Patterson 52773 N/A 3-SR-309 1992 Replaceaent 7 Description of World Re laced both s rin su rts for i su rts SR-308. and 3-SR-309 incl udin 1 aided eye rods and nuts per corrective action dispostion of KCR N-89-0339. 'iaiiieter

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other X N/A N/A .

Pressure- psl Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8112 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

gZ-Or'9-3.

~

~

Page 2 of 2 FORM NIS-2 (Back)

Exaainations perforsed by FPL Construction equality Control personnel-

9. Remarks Applicablo Manufacturer's Data Reports to bo attached "1 "eldin9 was perforraed in accordance with FP1 Meld Control manual and Site Procedures.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this <<Placeraent conforms to the rules of the ASME Code,Section XI. repair or replacement N/A Type Code Symbol Stamp Certificate of Authorization No. N/A Expiration Date Signed Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual System Commissions National Board, State, Province, and Endoisoments Date <~

nspector's

<9 9'~

gnature

i Page1of 3 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner F P WER & I HT Date LO/21/92 PO OX02 1 0 MIAMI F Add rrwa 5 Sheet 1

.f2

2. Plant TU POINT Unit Name Ctf0: 300481 PCH: 91-197 P.O. BOX 3088 FLORIDA CITY FL 33034 MO: 92044259 lIP IL- 92-106H Addreaa Repair Orgarrizarion p.o. No., Job No.. etc.
3. Work Performed by Type Code Symbol Stamp Authorization No.

Expiration Date N/A 4 (denticatlon of S tern Post Accf dent and Containment Venti 1 ation Quality Group ~H

5. (a) Applicable Construction Code 19 Edition, NA Addenda, I4 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components AS ME Name of Name of Manufacturer National Other R e p a Ired Board Year Replaced, Component Manufacturer Serial No. identification Built Stamped No. or Replacement (Yes or No)

GATE VALVE EST REPLACED HO t 1970 ITT DIAPHRAGH VALVE ElfGIHEERED 92 5o895 1 1 HV-3-1 REPULCBIEHT HO:

HA'ST EST GATE VALVE HO HV-3-2 1970 REPLACED HO>>

ITT EHGIflEERED DIAPGRAGH VALVE VLAVES 92-59895-1-2 NL HV-3-2 1992 REPULCEIKfT HO ~

GATE VALVE 1970 REPlACED'O .",

ITT EffGIHEERED DIAPHRAGH VALVE VALVES 92-59895-1-3 HA 1997 REPULCEHEHT HO QTrarueo o rJ r Ac,c, 9 off Work W rk REPULCED EXISTIffG GATE VALVES HITH DIAPHRAGH VALVES PER THE RE()UIRBIEHT OF PCH 91 197 7 D

7. Description I tl
8. Tests Conducted: Hydrostatic Pneumatic X Nominal Operating Pressure Other Pressure psl Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

'fZ-0/5-3

Page FORM HIS-2 (Back)

9. Remarks ESQ1INATIOtlS PERFORHED BY FPL CONSTRUCTION IIUALITY COtflROL PERSOtltlEL Applicabie Manufacturer's Data Reports to be attached ALL MELDItl6 MAS PERFORHED IN ACCORDANCE MITH THE FPL MELD COfffROL NANUAL AtlD SITE PROCEDURES CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEHEttT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date N/A Sign Date ,19 Owne r Owner's signee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to Ionue , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind a 'si m or connected with this inspection.

Factory Mutual System Commissions National Board, State, Province, and Endorsements

Pages of s FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Owner F 0 I OW & IGHT Date lo 21 9 2 2 P.O 029100 MIAMI FL 3315 Sheet f Plant TURK OINT Unit

'IIO S00481 PCH 91-197 P.O. BOX3088 FLORIDA CITY FL33034 lIO: 92044259 NPIL: 92-106N Addle Repair Oganization P.O. No. Job No.. etc.

~

3. Work Performed by Type Code Symbol Stamp Authorization No Expiration Date N/A 4 ldentlcatlon of System POST ACCIDENT AND CONTAIfDIENT VENTIULTION Quality Group B
5. (a) Applicable Construction Code 19 55 Edition, A Addenda. + Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identmcatlon of Components Repaired or Replaced and Replacement Components ASME Name of Manufacturer National Other Repaired, Code Name of Board Year Replaced, Component Manufacturer Serial No. No. Identification Built or Rephcem'ent No)

EST GATE VALVE 1970 REPUtCED I

ITT ENGINEERED I

.L DIAPHRAGH VALVE VALVES 92-59895-1-4 1992 REP LACENENT

7. Description of Work l 8. Tests Conducted: Hydrostatic Pressure Pneumatic Nominal Operating Pressure psl Test Temp.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Other Degree's F

Page 1 of 2 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT Date October 23, 1992 Name P.O. BOX 029100, MIAMI. FL 33102 Sheet 1 of Address TURKEY POINT Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 PWO: 0649 WOIs 92033260 IAlh +cl o I o Address Repar Crganizotion P.o. No. Job No. etc.

~

Performed by Fl ORIDA POWER 8c LIGHT Type Code Symbol Stamp N/A Name Author izotion N o. N/A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/A Expiration Date Address

4. Identification of System Intake Cooling Water Quality Group
5. (a) Applicable Construction Code ANSI B31 1 19 55 Edition, N/A Addenda. N/A Code Case (b) Applicable Edition ot Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Repaired, Code Other Year Stamped Component Manufacturer Serial No. Board identification Replaced, (Yes or No. or Replacement No)

Check Valve hfarlin W6730 N/A 3-50-321 N/A Replaced No Check Valve hiarlin 1l'6726 N/A 3-50-321 N/A Replacement No 7 Descriptipn pf 'Wprk Replaced valve at. tag location 3-50-32 1 due to excessive seat leakage.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp gg Degree's r NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

~

X 11in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is

~

numbered and the number of sheets is recorded at the top of this form. 92-021-3

Page 2 of 2 FOR M NIS-2 (Ba ck)

9. Remarks Mechanical connection, No weldinlr performed. Pressure test ¹03-1< f-1940-F-04.

Applicable Manufacturer's Octa Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this p" conforms repa's c 'eplacernent to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A N/A N/A Certificate of Authorization No. Expiration Date ner or Owner's Designee, Title Dote ~

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boilt and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Nor no i4. MA.

have inspected the components described in this Owner's Report during the period to A ril 17. 1992 , and state that to the best of my I owled ! ond belief, the Owner has performed examinations and taken corrective measures described in ti s Owner's Report in accordance with the requirements of ASME Code,Section XI.

By sigtting this certificate neither the inspector nor his employer makes any warrc.nty, expressed cr implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any persoral injury or property damage or a loss of any kind orising from or connected with the inspection.

I pector's Signature Commissions "" ooee Faci.6ry Mutual System Notional Board, '.

ote. Province. and Endorsements 19

FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT October 23, 1992 Name P.O. BOX 029100, MIAIII. FL 33102 Sheet 1 of 1 Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 PWOtt 9056 WOtt91058092 Address Repar Organization P.O. No.. Job No. etc.
3. Work Performed by FLORIDA POWER & LIGHT Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. BOX 3088. FLORIDA CITY, FL 33034 N/A Expiration Date Address
4. Identification of System Component Cooling Water Quality Group C
5. (a) Applicable Construction Code ANSI B31 1 19 55 Edition. N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980. Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of National Repaired, Code Name of Manufacturer Other Stamped Board RePlaced Component Manufacturer Serial No. Identification Bu,lt (Yes or or Replacement No.'/A No)

EST.

Pipe Hanger BergenPatterson N/A 3-ACH-143 1970 Replacement No 7 Description of 'Work Replaced Bolt and Nut with Load Pin as specified on as-built drawings t

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp Degree's F N/A NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used. provided (1) size is 8 1/2 in.

X 11in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 92-020-3

Page 2 of 2 FORM NIS 2 (Back) hfechanical connection, No welding performed.

Applicable Manufoct19'er's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this ep a e conforms repair or replacement to the rules of the ASME Code.Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A N/A Expiration Date 9;... Date 19 A ner or Owner's Oesienee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County. Florida and employed by Arlcwri ht hfutual Insurance Com an of Norwood. hfA.

have inspected the components described in this Owner's Report during the period to October 19. 1992 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore.

neither the inspector nor his employer shall be liable in any. manner for any personal injury or property dainage or a loss of any kind or'ng from or connected with the inspection.

Factory hfutual System Commissions 8230 N) I fnspector's Sitinatl e National Board, Stote. Province. ond Endorsements 19 ~

Page 1 of 2 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT Date October 23, 1992 Name P.O. BOX 029100, hfIAhfi. FL 33102 Sheet 1 of Address TURKEY POINT 3 Unit Name P.O. BOX 3008, FLORIDA CITY, FL 33034 PWO: 0660 WO¹ 92033318 gAI~<~zoQt 7 ggoQ+7 Address Repa'a'raanizatian P.O. Na.. Jab Na. etc.

Work Pe formed by FLORIDA POWER & LIGIIT Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. BOX 3080, FLORIDA CITY. FL 33034 N/A Expiration Dote Address

4. Identification of System Intake Cooling Water Quality Group
5. (a) Applicable Construction Code ANSI B31 1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASM'ode Manufacturer National Other Repaired, Name of Name of Year Stomped Manufacturer Serial No. Board Identification Replaced, Component Built (Yes or No. or Replacement No)

Check Valve Marlin W6726 N/A 3-50-321 N/A Replaced No Check Valve hfarlin 41104G15NG2 N/A 3-50-321 N/A Replacement No Description of Work Replaced valve at tag location 3-50-321.

l 8. Tests Conducted:

NOTE:

Hydrostatic Pressure Pneumatic pst Nominal Operating Pressure Test Temp gt Degree's F Other Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 I/2 in.

X 11in., (2) information in items 1 through 6 on this report is included on each sheetand (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 92-022-3

FORM NIS-2 (Back)

9. Remarks hlechanical connection, No welding performed. Pressure test. ¹03-ICl'f-1946-F-05.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this > " conforms repoir or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A N/A N/A Expiration Date Date , 19~

0 ner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Aricwri ht hfutual Insurance Com an of Norwood. hIA.

have inspected the components described in this Owner s Repo t during the period "Pn' ~

'o April 16, 1992 , ond state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or o loss of any kind arising from or connected with the inspection.

Factory hiutual System Commissions 6230 N I l actor's Signature National Board, State. Province, and Endcrsements

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Date 10/26/92 1

Sheet of

2. Plant Unit P.O. BOX3088 FLORIDA CITY FL33034 CMO: 500780 MO: 92044190 Addnas Repair Organizadon P.O. No., Job No., etc.
3. Work Performed by Type Code Symbol Stamp Authorfzathn No.

Expiration Date Add rees 4 Identificatio of System Quality Group C

5. (a) Applicable Construction Code 19 Edition, NA Addenda, NIA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Repaired, Board Year Replaced, Component Manufacturer Serial No. No. Identmcation Built or Replacement No)

VALVE HENRY PRATT 50270-1-2 N/A 3-50-350 1992 REPLACENENT NO VALVE HENRY PRATT 72463-1 N/A 3-50-350 N/A REPLACED NO REPUlCED VALVE 3-50-350

7. Description of Work
8. Tests Conducted: Hydrostatic X Pneumatic Nominal Operating Pressure Other Pressure 58 PSIG psl Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

RZ. -O>S

Page 2 of 2 FORM HIS-2 (Back)

Remarks EXAMINATIONS PERFORMED BY FPL CONSTRUCTION QUALITY CONTROL personnel Applicable Manufacttrrer's Data Reports to be attached CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp Certificate of A rization No. Expiration Date Signed Date ,19 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION" I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Cou Florida and employed by Arkwri ht Mutual Insurance Com n of Norwood MA have inspectedthe components described in this Owner's Report during the period to OCT 21 > 1992 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property

.damage r a loss of any kind arising from or connected with this inspection.

Factory Mutual System Commissions I'

Dat nspecer's

~

gnature

.19+

National Board, State, Province, and

Page1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner Date 10/26/92 Sheet of
2. Plant Unit P.O. BOX 3088 FLORIDA CITY FL 33034 Dfo: 500780 PS: 92-083 NO: 92044183 Add race Repair Organization P.O. No. Job No., etc.

~

3. Work Performed by Type Code Symbol Stamp Authorization No.

Expiration Date N/A

4. Identification of System INTAKE COOLING lIATER Quality Group C
5. (a) Applicable Construction Code 19 55 Edition, A Addenda, +A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components National ASME Name of Name of Manufacturer Other Manufacturer Serial No. Identification Replaced, Component No. or Rephcement (Yes or No)

VALVE HENRY PRATT SC111125-1 N/A 3-50-307 1992 REPLACENEffT NO" 4

1991" '

~

VALVE HENRY PRATT 107254-4-1 N/A 3-50-307 REPULCED NO 7 Description of Work REPLACED VALVE 3-50-307

8. Tests Conducted: Hydrostatic X Pneumatic, Nominal Operating Pressure Other 82.4 Pressure psl Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in.. (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Page2of2 FORM HIS-2 (Back)

9. Remarks EXAHINATIONS PERFORNED BY FPL CONSTRUCTION qUALITY CONTROL PERSONNEL Applicable Manufacturer's Oata Reports to be attached CERTIFICATION OF COMPLIANCE REPLACENENT We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp Certificate of Authorization No. Expiration Date Signed Owner or Owner's Designee, Title 0919 >9 +,199%

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Cou Florida and employed by Arkwri ht Mutual Insurance Com n of Norwood MA have inspected the components described in this Owner's Report during the period OCT 2 1 9 1992 to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual System Commissions Natknal Board, State, Province, and Endorsemen Da 19~~-

Pape 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions ot the ASME Code Section Xl F RI WR Date 10/28/92 1 1 1 IAMI F 1 Sheet of

2. Plant Unit Cttot 5008ll PCN: 92-029 I.L.:

P.O. 8OX 3088 FLORIDA CITY FL 33034

3. Work Performed by A&eaa ~ cpu 92-077K asce Type Code Symbol Stamp tf0: 920ll267 pe. W., m m., ~

Authorization No.

Expiration Date NIA 1

C Quality Group

4. Identification of System iti,
5. (a) Applicablo Construction Code 19 Edition, + Addenda, N/ Code Case (b) Applicablo Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
8. Identification of Components Repaved or Replaced and Replacement Components Manufadurer National Other Yoaf Repaired, Name of Name of 8oard Replaced, Manufacturer Serial No. Identification 8uilt Stamped Component No. Replacement (Yes or No 8051-H- EST SPRIK6 HAK6ER 001-04 1970 KD" Karkf SPRIK6 HAK6ER BER6EK PATERSON 8052253 62l9-0001 1992 REPLACED SUPPORT 8051-H-001-Ol OK CHEKICAL AKD VOLANS MKTROL SYSTGt TO %ET THE
7. Description of Work DESI6K OF PC/tt 92-029
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

sheet is X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each numbered and the number of sheets is recorded at the top of this form.

Page 2 of 2 FORM HIS-2 (Back)

9. Remarks Appltcable Marwfacturor's Data Reports to bo attached ALL MELDING MAS PERFORMED IN ACCORDANCE MITH THE FPL MELD CONTROL NNUAL AND SITE PROCEDURES CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this. REpLAcENENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A CertiTicate of rization No. Expiration Date I'

Sig Chvner or Owner's Designee, Title Date k CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, hokfing a valid commission issued by the National Board of Boiler and Pressure Vessel

't inspectors and the State or Province of Arhv Mutual Insurance Com n Dade Coun of Rorida Norwood MA and empfoyedby have inspected the components described in this Owner's Report during the period Ot oheg 2. , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance wilh the requiremenls of ASME Code,Section XI.

a" By signing this certiTicate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning ihe examinations and corrective measures described in this Owners Report. Futhermore, neither the inspeclor nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual System Commissions poctor s QnalUre Natkxiat Board, State, Province, and Endorslnonts Oa t9 WZ

Page1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner W Date 1 1 Sheet off
2. Plant Unit CNO: 500782 MO: 92053480 P.O. BOX 3088 FLORIDA CITY FL 33034 NCR-N-92-0262 CNR: 92-3-042 Address Repair Ontsnhstbn P.O. No., Jab No. stc.

~

3. Work Performed by Type Code Symbol Stamp Authorization No.

Expiration Date N/A

4. Identmcation of System Quality Group
5. (a) Applicable Construction Code 19 Edion. N/A Addenda, N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
8. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National

'oard Other Year Repaired, AE Component Manufacturer Serial No. Replaced, No. Identification Built or Replacement No)

EST PIPING RHR 3-89-Al-lA '970 REPAIRED NOt REPAIRED BY BUFFIttG 9 LINEAR INDICATIONS AT PENETRATION SLEVE.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

\

Page 2 of 2 FORM HIS-2 (Back)

9. Remarks NO KELDIH6 PERFORMED Apptfcabfe Manufacturer's Data Reports to be attached Examinations erformed b FPL Constructio personnel CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp Certificate of Authorization No. Expiration Date

~A i l Signed Date ,19M Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Cou Florida and employed by Arkwri ht Mutual Insurance Com n of Norwood MA have inspected the components described in this Owner's Report during the period to ~.- C' and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual System Commissions s gnature National Board, State, Province, and Endorsemen 19 FZ

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner 10/30/92 1 1 Sheet of
2. Plant T Unit CMO: 500782 P.O. BOX 3088 FLORIDA CITY FL33034 M/0 92052750, NCR-92-0252. CIIR 92-3-027 Repair Organization P.O. No. Job No., etc.

~

3. Work Performed by Type Coda Symbol Stamp Authorlzathn No Expiration Date N/A
4. Identification of System SAFETY INJECTION Quality Group B
5. (a) Applicable Construction Code 19 55 Edition, Addenda, NA Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identmcatlon of Components RepaIred or Replaced and Replacement Components Name of Name of Manufacturer National Other Repaired, Board Year Replaced, Component Manufacturer Serial No. No. Identification Built or Replacement No)

PIPING SI fl/A N/A N/A 0%SI-2303-4 1970 REPAIRED NO:

BUFFED 5 GRINDING TO REPAIR INDICATIONS AT TOM OF HELD Descrf tlon of Work

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other N/A Pressure psi Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

0 -csee-Z

Page2of2 FORM NIS-2 (Back)

9. Remarks NO lfELDIH6 PERFORNED Applicable Manufacturer's Data Reports to be attached Examinations erformed b FPL ual ity Control personnel CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this R R conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp Certificate of Authorization No. N/A Expiration Date Signed D~te //OQ ,19 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Cou Florida and employed by Arkwri h Mutual Insurance Com n of Norwood MA a

to

- ~rZ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind ari ing from or connected with this inspection.

Factory Mutual System Commissions nspecax's gnature National Board, State, Province, and Dat 19 F~

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 10-31-92

1. Owner Date 1

PO 0 I 5 Sheet of

2. Plant TU POI Unit Nemo CKO 300328 NPIL 92-080N PCN 90-261 MO 91058255 P.O. BOX 3088 FLORIDA CITY FL 33034 Addnee Repair Otgenizetion P.O. No., Job No., etc.
3. Work Performed by Type Code Symbol Stamp Authorization No.

Expiration Date N/A

4. Identication of System SafetY Injection f64 Quality Group, 8 B31. 19 55 Edition, NIA Addenda, NIA Code Case
5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components Name of Manufacturer National Other Year Repaired, Name of Board Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No .

EST 1970 REPLACED NOr H-15 NA H-15/H-15A 1992 REPLACEMENT NO EST 1970 REPLACED Not.

H-24/H-24A 1992 REPLACENENT N0$

Replaced existing 2" dia. pipe strap su'pport with a new dual 2" pipe strap

~

7. Description D I W k off Work support per PCN 90-261
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

92-024-3

Page2of2 FORM HIS-2 (Back) g Fternarks All welding was performed in accordance with the FPL Meld Control Hanual and Site Procedures.

Applicabte Manufacturer's Data Reports to be attached Examinations performed by FPL Construction tiuality Control personnel.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this Replacement conforms to the rules of the ASME Code,Section XI. repair or replacement N/A Type Code Symbol Stamp N/A Expiration Date N/A Certificate of Authorization No.

Signed Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to it- Z. 2. , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arisi from or connected with this inspection.

Factory Mutual System Commissions Dat c/'9 I pector's Signature 9'Z National Board, State, Province, and Endorsements

Pape 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

t. Owner 11/3/92 Shoat of
2. Plant Unit P.O. BOX 3088 FLORIDA CITY FL 33034 CMO 500782, NCR-N-92-0224, MO: 92052937 s Address Aapar Orpsrta~n P.O. No.. Jab No.. etc.
3. Work Performed by Type Code Symbol Stamp Authorfzaton No.

Explrathn Date N/A CCM

4. Identification of System QUalltr GtoUP Q
5. (a) Applicable Construction Code B31.1 19 & Edithn, NA Addenda, N/A (b) Applicable Edltkwt of Socdm XI Utilized for Repairs or Replacements 1980, Editkrn, Winter 1981 Addenda
6. Identmcation of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer Natonal Other Year R ~r'~,

Board Replaced, Stamped Component Manufacturer Serial No. No. Identmcatfon Built Replacement (Yes or No)

CCM PIPIN6 16727 1970 CCM PIPIN6 I/A 3-1099 '992 h

REPLACED PSA 1/2 SNUBBER 3-1099 MITH PSA 1/4.REFERENCE DRAMIN6 5613-H-629o SHEET 3A, 3B, 3C

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psi Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

I ~ ~ v'hp v

(2) h:I'O'hna '

o'v' 0 h,aa ~

.1q p,,h' \ h a" v 'y

< -'.=;: 8 th:vrot'qn 6 O. +lS re~r.," r~ihld+v On caen Sheet and {3'1 e-C,. Sheer 'G

~ ho 1 s hv hÃvvhvvv

~

hjvthahasva c 1 woo v; spy~

ha[ aA v... ~ .v leh h

~ ~ ~

~7Z- 893-

Pape 2 of 2 FORM HIS-2 (Back)

9. Remarks Exaninations perfomed by FPL Construction equality Control personnel.

Appttcabte Manuracturer's Data Reports to be attacned ALL lIELODlG HAS PERFORlIED 'fl ACCORD@I/O t!ITII TIIE FPL HELD COfITRDL I'ulfIU/'L AfID S'TE PPGCEDURES.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPUtC~NT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp 9

Certificate of Authorization No. Expiration Date Signed Owner or Owner's Designee, Title Date "/ ' ta~>

CERTIFICATE OF INSERVICE INSPECTION I, the undeisfgned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Cou Florida and employed by Arkw I m of Norwood MA have inspected the components described in this Owner's Report during the period to Z- , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By'signing this certifcate neither the inspector nor his employer makes anywarranty, expressed or implied, conceminp -e examinations and-corrective measures described in this Owners Report. Futhermore, nhither the inspect: or his employer shall be liable in any manner for any personal injury or property damage r a loss o; -ny kind arising from or connected with this ins pection.

~Date l8: Aspic 19'actory, gnature Commissions Mutual System National Board, State, Province, and Endorsernents

Page1of2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

t. Owner ll/5/92 1

P.O MIAMI 1 Sheet of

2. Plant Unit CNR: 92-3-022 CMO: 500981 P.O. BOX 3088 FLORIDA CITY FL 33034 MO: 92052438 NCR-N-92-0241 Addresa nepair Organization p.O. No. Job No., etc.

~

3. Work Performed by Type Code Symbol Stamp Name Authorization,No.

Expiration Da'te N/A

4. IdentiTicatlon of System Quality Group 8 t 9 55 Edition, N/A Addenda, N/A Code Case
5. (a) Applicable Construction Code (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identiflcation of Components Repaired or Replaced and Replacement Components National Other Repaired, Name of Name of Manufacturer Board Replaced, Manufacturer Serial No. identification Built Sgmped Component No. or Rephcem'ent No) 14" FMC EST PIPING FM 2306-5A 1970 REPAIRED NO PERFOIDIED MELD REPAIR ON PIT IN THE EXTERIOR MALL OF THE FIRST ELBOM DOMNSTRBN
7. Description of Work OF VALVE 3-20-133
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other 0 Pressure psl Test Temp.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each Degree's F sheet is numbered and the number of sheets is recorded at the top of this form.

Pz-Dz7-~

Page 2 of 2 FORM NlS-2 {Back)

9. Remarks EXAMINATIONS PERFORMED BY FPL CONSTRUCTION tIUALITY CONTROL PERSONNEL.

Apptlcable Manufacturer's Data Reports to be attachod ALL MELDING PERFORMED IN ACCORDANCE MITH FPL MELD CONTROL MANUAL AND SITE PROCEDURES CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp Certificate of Authorization No. Expiration Date N/A Date 19 9z Signed ~

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arisipg from or connected with this inspection.

P Factory Mutual System Commissions Ins r's gnatuie Nathnal Board, State, Province, and Endorsomonts Dat 19~Z .

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER 8c LIGHT Dote November 6, 1992 Nome P.O. BOX 029100, hiIAhil, FL 33102 Sheet 1 of Address TURKEY POINT Unit Name P.O. BOX 3000, FLORIDA CITY. FL 33034 PWO: 0609 WOtt92031703 Address Reigar organization P.a. No.. Job No. etc.

Work Performed by FLORIDA POWER 8c LIGHT Type Code Symbol Stamp Name Authorization No. N/A P.O. BOX 3000, FLORIDA CITY, FL 33034 Expiration Date Address

4. Identification of System Intake Cooling Water Quality Group
5. (a) Applicable Construction Code ANSI B31 1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Manufacturer National Repaired, Code Name of Name of Other Year Stamped Board Replaced.

Component Manufacturer Serial No. Identification Built (Yes or No. or Replacement No)

Spare ICW Pump JohnstonpumpCo. N/A IST st5 1970 Replaced No 7 Description of 'Work Replaced pipe columns.* Per AShIE Sect.XI IWD 5223(d), confirmation of adequate flow will be performed upon reinstallation during 3-0SP-19.1

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure pst Test Temp Degree's F NOTE: Supplemental sheets in form of lists. sketches, or drawings may be used. provided (1) size is 8 1/2 in.

X 11in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 92-029-3

Page 2 of 2 FORM HIS 2 (Back)

Mechanical connection. No welding performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPUANCE We certify that the statements made in the report are correct and this p conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp Certificate of Authorization No. N/A N/A Expiration Date Signed

')AA) mf.'~

litle Date Owner or Owner's Designee.

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood, MA.

have inspected the components described in this Owner's Report during the period to November 6. 1992 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

Sy signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual System Commissions 0230 N I inspector's Signature National Board, State, Province. and Endorsements

Page 1 of 2 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT Date November 6, 1992 Nome P.O. BOX 029100. hfIAhiI. FL 33102 Sheet 1 of Address TURKEY POINT 3 Unit Nome P.O. BOX 3088, FLORIDA CITY, FL 33034 PWO: 9949 WOtt9 1058 142 Address Repo'g'rgonizotion P.O, No. Job No. eto.

~

Work Performed by FLORIDA POWER & LIGHT Type Code Symbol Stamp N/A Nome Authorization No. N/A P,O. BOX 3088, FLORIDA CITY, FL 33034 N/A Expiration Date Address

4. Identification of System Intake Cooling Water Quality Group
5. (a) Applicable Construction Code ANSI B31.1 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980. Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Nome of Manufacturer National Repaired, Code Other Year Stamped Manufacturer Board Replaced.

Component Serial No. Identification Built (Yes or No. or Replacement No)

Ball Valve Watts B6000 N/A N/A 3-50-409 N/A Replaced No Ball Valve ill'atts B6000 N/A 3-50-409 1992 Replacement No 7 D

'Work Replaced valve at tag location 3-50-409 due to broken valve handle.

t

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure Test Temp tt> Degree's F NOTE: Supplemental sheets in form of lists, sketches. or drawings may be used, provided (1) size is 8 1/2 in.

X 1lin. '(2) information in items 1 through 6 on this report is included on each

~

sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. 92-028-3

Page 2 of 2 FORM NIS 2 (Back)

9. Remarks hiechanical connection, No welding performed. Pressure Test ¹03-ICW-1946-L-02 Applicobte Nionufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report ore correct and this p conforms repair or replacement to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/A N/A Expiration Oate Signed H/t>f r ~En ~ 19 Owner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood. hIA.-

have inspected the components described in this Owner's Report during the period to November 3, 1992 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASM'ode, Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory hiutual System Commissions 8230 N I Inspector's Siqnoture Notional Ooord. State. Province. and Endorsements

Page1of Z FORM NlS-2 OWNER'S REPORT FOR REPA(RS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner F Date ll 10 92 1

P.O OX 0 100 1AM F 1 Sheet of Addrees 1

2. Plant P Unit 3 CMO: 500998 MO: 92054400 P.O. BOX 3088 FLORIDA CITY FL 33034 Addnas Repair Organization P.O. No., Job No., etc.
3. Work Performed by Type Code Symbol Stamp Authorization No Expiration Date N/A
4. Identmcatlon of System INSTRUMENT AIR Quality Group
5. (a) Applicable Construction Code 19 55 Fdition, <A Addenda; + Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repa!red or Replaced and Replacement Components Name of Name of Manufacturer National Other Repaired, Board Year Replaced, Component Manufacturer Serial No. No. Identification Built or Replacement No)

CHECK NLVE tlA 3-40-336 REPAIRED NO PLACED HINGE P 7 Description of Work

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psl Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Page2of Z FORM HIS-2 (Back)

9. Remarks EXAHItJLTIONS PERFORNED BY FPL CONSTRUCTION UALITY COffTROL PERSONNEL.

Applicable Manufacturer's Data Reports to be attached 11ECHANICAL CORRECTION, NO NELDIHG PERFORHED.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp Certificate of Authorization No. Expiration Date Signed D t // l/ EM ~ $ 9 Owner or Owner's Designee, Title CERTIFICATE OF INSERYICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Yessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to 11/10/92 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising f m or connected with this inspection.

Factory Mutual System ommissions ns s 'gnature National Board, State, Province, and Endorsements 19~+~

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPA(RS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section Xl

1. Owner FL W 8 Date 11/11/92 P,O. BOX 029100 MIAMI FL 33152 Sheet of 2 Plant T K Unit CMO: 500782 P.O. BOX 3088 FLORIDA CITY FL 33034 MO: 92052376 NCR-Ii-92-0242 Addmss Repair Otttanizaiien P.O. Na. Job No., etc.
3. Work Performed by Type Code Symbol Stamp Name Authorization No Expiration Date N/A Addtess CCM
4. Identification of System Quality Groug C
5. (a) Applicable Construction Code 19 55 Edition, N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components AS ME Name of Name of Manufacturer . National Other Year Repaired, Board Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Replacement (Yes or No)

EST COIIPONENT COOLING MATER 3-SR-345 1970 REPAIRED IIO

7. Description of Work
8. Tests Conducted: Hydrostatic, Pneumatic Nominal Operating Pressure Other NA, Pressure psl Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Page 2 of 2 FORM HIS-2 (Back)

9. Remarks NO MELDIN6 PERFORNED Applicable Manufacturer's Data Reports to be attached EXANINATIONS PERFORMED BY FPL CONSTRUCTION fIUALITY CONTROL PERSONNEL CERTIFICATION OF COMPLIANCE

'e certify that the statements made in the report are correct and this REPAIR conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. N/A Expiration Date Signed Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes anywarranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kin 'ng from or connected with this inspection.

Factory Mutual System Commissions Inspector's S gnature National Board, State, Province, and Endorsements DatK

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI Owner F I P WER8 I Date ll ll 92 1

P.O. BOX 0291 00 MIAMI FL 3315 Sheet of Address

2. Plant TUR Unit CHO: 500782 HO: 92054118 HCR-N-92-0284 CHR 92-3-051 P.O. BOX 3088 FLORIDA CITY FL 33034 Address Repeir Organizrriion P.O. No.. Job No. etc.

~

3. Work Performed by Type Code Symbol Stamp Nome Authorization No.

Expiration Date N/A Address

5. (a) Applicable Construction Code RESIDUAL HEAT REHOVAL B31.1 19 55 Edition, N/A Addenda, Quality Group N/A

~ Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda

6. Identification of Components Repaired or Replaced and Replacement Components Manufacturer , National Other Repaired, Name of Name of Board Year Replaced, Identification Built Stamped Component Manufacturer Serial No. No. .

or Replacement (Yes or No)

RHR HEAT EST EXCHANGER 3E206A 1970 REPAIR KO MFFED 5 GRINDED LINEAR IHDICATIOH OH SUPPORT 3-RHE-SPA-2 LUG

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other HA Pressure psi Test Temp. Degree's F NOTE: Suoolementai sheets in form of lists. sketches. or drawings maybe used. o.ovided (',) size is 81/2 in.

II, .r 4" h 9 ", ~ rr g ' ~ si w.wn I . i-wo,. re rr,~ ~-h rs n-. ~ ar Ierr..V l~f

~ i " -,ent rS

'~

~ .

r I

~

4'-'IQ-ha 1

~ ~

~ v Y' an rtLpl err +1 I

~ s

~ t 5i l r h .

r ~ r p @(Ill vl 0 s o spl ' ~ 'S

-3

Page 2 of 2 FORM HIS-2 (Back)

9. Remarks NO WELDING PERFORHED Applicabte Manufacturer's Data Re ports to be attached EXAHINATIONS PERFORHED BY FPL CONSTRUCTION (ItjALITY CONTROL PERSONNEL.

CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPAIR conforms to the rules of the ASME Code,Section XI. repair or replacement N/A Type Code Symbol Stamp C ertificate of Authorization No. N/A Expiration Date SIgned Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel

't Inspectors and the State or Province of Arkw Mutual Insurance Com an Dade Coun of Florida Norwood MA and employed by have inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither th" "spector nor his emclcyer makes any warranty, expressed or implied, concerning xaminations and c'tive measures described in this Owners Report. r uthermore.

neither the inspectc.;,is employer shat; able in any manner for any personal injury or property damage or a loss oi a>>y rtind arising from or connected with this inspection.

Factory Mutual System Commissions I~ter's Signature Nationai Board, State, Province. and Endorsements

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT November 19, 1992 Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT Unit Nome P.O. BOX 3088, FLORIDA CITY, FL 33034 PWON 2547 WON 92053077 Address Repair Orpanizauon P.O. No.. Job No. elc.

Performed b FLORIDA POWER & LIGHT Type Code Symbol Stamp N/'A Name N/A Authorization No.

P.O. BOX 3088, FLORIDA CITY, FL 33034 Expiration Date N/'A Address

4. Identification of Syste Residual Heat Removal Quality Group NiA Addenda, N/'A
5. (a) Applicable Construction Code ANSI B31 1 1955 Edition, Code Case (b) Applicable Edition of Section XI Utilized for Repairs orRoplacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Nationa Repaired, Code Name of Name of Manufacturer Other Year Stomped Board Identification Replaced, Component Manufacturer Serial No. Built or Replacement (Yes or No.

No)

EST.

Pump Restraint Pacific Scientific 3-1028/ 1029 N/'A SR3 Repaired No 1970 7 Description of 'Work Replaced load pins on snubbers 3- 1028 and 3- 1029 at support SR3.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure ps l Test Temp Degree's r N/A NOTE: Supplemental sheets in form of lists, sketches, or drawings may beused, provided (1) size is 8 1/'2 in.

~

X 11in., (2) information in items 1 through 6 on this report isincluded on each sheet. and (3) each sheet~is numbered and the number of sheets is recorded at the top of thiform. 92-036-3

Page 2 of 2 FORM NIS-2 (Back) arks 9 Remarks

9. R Mechanical connecfion, No welding performed.

Applicable Manufacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE repaired conforms We certify that the statements made in the reporl are correct and this repair or replacement to the rules of the ASME Code,Section XI.

Nf'A Type Code Symbol Stamp NI A Nr A Certificate of uthorizafion o. Expiration Date Signed 19 'l3 wner or Owner's Designee, Litle CERTIFICATE OF INSERVICE INSPECTION I, fhe undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood. MA.

May 19, 1992 have inspected the components described in this Owner's Report during theperio to November 16. 1992 , and state that fo the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Reporl. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or properfy damage or a loss of any kind arising from or connected with lhe inspection.

Factory Mutual System Commissions 8230 N Inspect s Signature Nattonat Board, Slate, Provfnce, and Endorsements 0 40 19 Z

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT November 19. 1992 Nome P.O. BOX 029100, MIAMI, FL 33102 1 of 1 Address TURKEY POINT Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 PWO: 9056 WO¹ 91058216 NCR¹ N-92-0279 Address Repair Oreonlza¹an P.O. No., Jab No. elc FLORIDA POWER lk LIGHT N/'A 3 W<<k Performed b Type Code Symbol Stamp Name N/'A Authorization No.

P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Safety Injection System Quality Group ANSI 831 1955 Edition, N/A Addenda, N/'A Code Case
5. (a) Applicable Construction Code 1 (b) Applicable Edition of Section XI Utilized for Repairs orReplacements 1980. Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Nationa Repaired, Code Name of Name of Manufacturer Other ear Stamped Board Replaced, Component Manufacturer Serial No. Identification B lt (Yes or No. or Replacement No)

Piping Support N/'A N/'A N/'A '426F'ST. 1970 Repaired No Descript;on of Wok Replaced U bolt

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure Psl Test Temp Oepree's p Mr'A 1/'2 in.

NOTE: Supplemental sheets in form of lists, sketches, or drawings may beused, provided (1) size is 8 isincluded on each sheet, and (3) each sheet, is X 11ln.. (2) information in items 1 through 6 on this report nulnbered and the number of sheets is recorded at the top of thiform. 92-037-3

~ " ~

Page 2 o( 2 FORM NIS-2 (Back)

Mechanical connection, No welding performed.

Applicable Manutaclurer's Data Reports lo be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repaired conforms repair or replacement to the rules o( the ASME Code.Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No. N/'A NiA Expiration Date Signed g&pl . AtG Q >

Date 19 ~L r or Owner's Oestgnee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an o( Norwood. MA.

have inspected the components described in this Owner's Report during theperio to November 12. 1992 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furlhermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual System Commissions 8230 N I clor's SIgnature National Board, Slot ~, Province, and Bndorsements 19

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT November 20, 1992 Nome P.O. BOX 029100, MIAMI, FL 33102 Shoot 1 of Address TURKEY POINT

2. Plant Unit U t Name P,O. BOX 3088, FLORIDA CITY, FL 33034 PWO¹ 1016 WO¹ 91058428 A dress Repair Organlzollon P.O. No.. Job No. ele.

Work Performed b FLORIDA POWER & LIGHT Type Code Symbol Stamp NINA Name Authorization No. N j'A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Idontification of Syste Reactor Coolant System Quality Group N/A N/'A S. (a) Applicable Construction Code ANSI 831 1 1955 Edition, Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs orReplacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Nationa Other Year Repaired, Code Name of Name of Manufacturer Stamped Board Identification Replaced, Component Manufacturer Serial No.

No.

Built or Replacement (Yes or No)

EST.

Safety Valve Crosby Nj'A N j'A RV-3-551C Replaced No 1970 Description of 'Work Replaced bolting on valve RV-3-55 1C (Pressure Test per OP 1004. 1) 7 t 8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Pressure psl Test Temp sggg Degree'e r NOTE: Supplemental sheets in form of lists, sketches, or drawings may beused, provided (1) size is 8 1/'2 in.

X 11in., (2) information in items 1 through 6 on this report isincluded on each sheet, and (3) each sheet is numbered and tho number of shoots is recorded at tho top of thiform. 92-039-3

Page 2 of 2 FORM HIS-2 (Back)

Mechanical connection, No welding performed.

Applicable Manutacturer's Data Reports to be attached CERTIFICATE OF COMPLIANCE P m conforms We certify that the statements made in the reporl are correct and this repair or replacement to the rules of the ASME Code,Section XI. lt N/'A Type Code Symbol Stamp N/'A N/'A Cerlificate of Authorization No. Expiration Date Signed D,l, PW 0 er or Owner's Designee. title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood. MA.

have Inspected the components described In this Owner s Report during theperlo M'y '

'o November 20, 1992 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this cerlificate neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or properly damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual System Commissions NB 8230 N I I peclor's Signature National Board. Slate. Province, and Endorsements

Pago 1 of 2 FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER 8r. LIGHT November 20. 1992 Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of 1 Address TURKEY POINT

2. Plant Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 PWON 2288 WON 92044301 Address Repair Oreanlzallan P.O. Na., Job Na. ele.
3. Work Performed b FLORIDA POWER Ik LIGHT Type Code Symbol Stamp N/'A Name N/'A Authorization No.

P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Safety Injection System Quality Group
5. (a) Applicable Construction Code ANSI 831 1 1955 Edition, N/A Addenda, Code Case (b) Applicable Edition of Section XI Utilizod for Repairs orReplacements 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Nationa Repaired, Code Name of Name of Manufacturer Other Year Stamped Board Identification Built Replaced, Component Manufacturer Serial No.

or Replacement (Yes or No.

No)

EST.

Globe Valve Crane Alloyco N/'A N/'A 3-897 D Replaced 1970 Globe Valve Henry Vogt N/'A N/'A 3-897D 1988 Replacement No

7. Description of Work Replaced 3-897D (RWST drain valve) t
8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other pressure Static Head psi Test Temp Amts'eet Degree's r NOTE: Supplemental sheets in form of lists, sketches, or drawings may beused, provided (1) size is 8 1/'2 in.

X 11in(2) information in items 1 through 6 on this report isincluded on each sheet, and (3) each sheotgis numbered and the number of sheets is recorded at tho top of thikorm. 92-038-3

FORM NIS-2 (Back)

All welding was performed in accordance with FPL Weld Control Manual and Site Procedures.

9. Remarks Applicable Manu(aclurer's Bala Reports lo be allached CERTIFICATE OF COMPLIANCE P e conforms We certify that the statements made in the report are correct and this repair or replacemenl to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/'A Ni'A Nl'A Certificate of Authorization No. Expiration Date Date 19 $ 2 Signed ner or Owner's Designee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com on of Norwood, MA.

have inspected the components described in this Owner's Report during theperio to November 18, 1992 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this cerlificate neither the inspector nor his employer makes any warranty. expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or properly damage or a loss o( any kind arising from or connected with the inspection.

19'ommissions nspeclor's Signalure Factory Mutual System 8230 N I kalional Board. Slale. Province, and Endorsemenls

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER Ik LIGHT December 2. 1992 Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 'of 1 Address TURKEY POINT Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 PWOss 1115 WOst 92032383 Address Repair Organlzallon P.O. No.. Job No. elc.

3 Wo,k Performed b FLORIDA POWER tk LIGHT Type Code Symbol Stamp N/'A Name  %'A Authorization No.

P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Intake Coolin Water Qualify Group C
5. (a) Applicable Construction Code ANSI B31 ~ 1 1955 Edition. N/A Addenda, N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
6. Identification o( Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Repaired, Code Y Stamped Board Replaced.

Component Manufacturer Serial No. Identification B lit (Yes or No. or Replacement No)

EST.

JohnstonPumpCo. N/'A N/'A IST-5 Replaced No 1970 EST.

ICW Pump JohnstonPumpCo. N/'A N/'A IST-1 Replacement 1970

7. Description of Work Replaced ICW Pump B.

t 8. Tests Conducted:

NOTE:

Hydrostatic Pressure 17 Pneumatic PSl Nominal Operating Pressure Teel Temp 72 Degree s F s Other Supplemental sheets in form of lists, sketches. or drawings may be used, provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 92-040-3

Page 2 of 2 FORM NIS-2 (Back)

Mechanical connection. No welding performed. Pressure test tt03-ICW-1948-F-03

9. Remarks Applicable Manufacturer's Data Reports lo be attached CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this P " conforms repair or replacement to the rules of the ASME Code.Section XI.

NJ'A Type Code Symbol Stamp Certificate of Authorizati No.

&'A N/'A Expiration Date Signe Date /> /ir Owner or Owner's Designee. Tttte CERTIFICATE OF'NSERVICE INSPECTION I, the undersigned,,holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood, MA.

have inspected the components described in this Owner's Report during theperio to March 27. 1992 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Reporl. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or properly damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual System Commissions NB 8230 N I Ins ctor's Signature ttattonat Board. Stale. Province, and Endorsements at ~<<19 ~~

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT December 9, 1992 D I Name P.O. BOX 029100, MIAMI, FL 33102 Sheet t of Address TURKEY POINT Unit Name P.O. BOX 3088, FLORIDA CITY, FL 33034 PWOsr 1417 WOrr 92032386 A ress Reparr Oreanizallon P.O. No., Job No. elo.

Work Performed b FLORIDA POWER & LIGHT Type Code Symbol Stamp N/A Name N/'A Authorization No.

P.O. BOX 3088, FLORIDA CITY, FL 33034 N/A Expiration Dote Address

4. Identification of Syste Intake Coolin Wafer Quality Group C N/A N/'A
5. (a) Applicable Construction Code ANSI 831 1 1955 Edition, Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacemenfs 1980, Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME National Repaired, Code Name of Name of Manufacturer Other Year Stamped Board identification Replaced.

Component Manufacturer Serial No. Built (Yes. or No. or Replacement No)

W-6727 3-50-321 not Check Valve Marlin N/'A Replaced No 41104G15NG2 know Marlin W-6730 N/'A 3-50-321 not No Check Valve know Replacement

7. Description of Work Replaced ICW Pump B discharge check valve.

t

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other 17 TS Pressure ps l Test Temp NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/'2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 92-041-3

Page 2 of 2 FORM NIS 2 (Back)

Mechanical connection, No welding performed. Pressure test st03-ICW-1948-F-03

9. Remarks Appllcoble Manufacturer's Data Reporls lo be attached CERTIFICATE OF'OMPLIANCE eP men conforms We certify that the statements made in the report are correct and this repair or replacement to the rules of the ASME Code,Section XI.

N/'A Type Code Symbol Stamp N/'A NINA Certificate of Authoriz ion No. Expiration Date Date V/C(

Signed Owner or Owner's slpnee. TBI~

CERTIFICATE OF'NSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County, Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood. MA.

have inspected the components described in this Owner's Report during theperio to March 27. 1992 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or properly damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual System Commissions NB 8230 N I Inspe or's Stpnalure National Board. Slate. Province, and Endorsements

Page 1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI FLORIDA POWER & LIGHT December 14, 1992 Date Name P.O. BOX 029100, MIAMI, FL 33102 Sheet 1 of Address TURKEY POINT Unit Nome P.O. BOX 3088, FLORIDA CITY, FL 33034 PWO¹ 5519 WA¹ 900928094143 A ress Repair Orgattizallott P.a. No.. Job No. etc.

3 W<<k Performed b FLORIDA POWER & LIGHT Type Code Symbol Stamp N/A Name Authorization No. N/A P.O. BOX 3088, FLORIDA CITY, FL 33034 N/'A Expiration Date Address

4. Identification of Syste Reactor Vessel Quality Group A
5. (a) Applicable Construction Code ANSI B31 ~ 1 1955 Edition. N/A Addenda. N/'A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980. Edition, Winter 1981 Addenda
6. Identification of Components Repaired or Replaced and Replacement Components ASME Name of Name of Manufacturer National Other Year Repaired, Cade Board Replaced, Stamped Component Manufacturer Serial No. Identification Built (Yas or No. or Replacement Na)

EST.

RV Head Stud Babcock & Wilco N/A N/A RV Stud ¹50 1970 Replaced No RV Head Stud Babcock & Wilco F'-18 NINA RV Stud ¹50 1989 Replacement EST.

RV Head Stud Babcock & Wilco N/'A N/'A RV Stud ¹51 1970 Replaced No RV Head Stud Babcock & Wilco K-22 N/A RV Stud ¹51 1989 Replacement No Descr,pt;on of Work PePlaced Reactor Head Studs ¹50 and ¹51. Work Performed on WA¹900928094143 k

serial numbers were verified later on W091058907.

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other pressure gggg pst Test Temp S ggg Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used,

~ provided (1) size is 8 1/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each

~ sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form 92-042-3

Page 2 of 2 FORM NIS-2 (Back)

Mechanical connection, No welding performed. Pressure test ¹03-ICW-1948-F-03 ApplIcable Monufaclurer's Dale ReporIs lo be allached CERTIFICATE OF COMPLIANCE We cerlify that the statements made in the reporl are correct and this P " conforms repair or replacemenl to the rules of the ASME Code,Section XI.

Type Code Symbol Stamp N/'A Certificate of Authorization N/'A N/'A

o. Expiration Date Signed R+g( - H&/L Daie 0 r or Owner's Designee. nile CERTIFICATE OF INSERVICE INSPECT/ON I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade County. Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood. MA.

have Inspected the components described in this Owner s Report during theperio 'P to March 24, 1992 , and state that to the best of my knowledge and belief, the Owner has performed exalninations and taken corrective measures described in this Owner's Reporl in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore neither the inspector nor his employer shall be liable in any manner for anypersonal injury or property damage or a loss of any kind arising from or connected with the inspection.

Factory Mutual System Commissions NB 8230 N I Inspe or's Slgnalure IIallonol Board, Slote. Province, and Endorsements Da 19~+

Page1 of 2 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner FL I W & Date 12/21/92 1 1 P.O. BOX 029100 MIAMI FL 33152 Sheet of CMO: 501013 NCR: 92-0138 MOf: 92042869
2. Plant P.O. BOX 3088 FLORIDA CITY FL33034 Addnes Repar ontsntzstion P.o. No., Jab No., etc.
3. Work Performed by Type Code Symbol Stamp Authorization No Expiration Date N/A 4 ldentmcation of System INTAKE COOLIN6 WATER Quality Group
5. (a) Applicable Construction Code 19 Edition, NA Addenda, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1980, Edition, Winter 1981 Addenda
8. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer , National Other Year Board Replaced, Stamped Component Manufacturer Serial No. No. Identification Built or Rephcement (Yes or No)

EST PIPE SPOOL ICM N/A N/A. N/A 3-20"-13-L 1970 REPLACED NO PIPE SPOOL ICM N/A N/A N/A 3-20"-13-L 1992 REPLACENENT NO'EPLACE PIPE SPOOL PER NCR 91-0138 SYSTEN

8. Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other X FtmCTIONAL Pressure psl Test Temp. Degree's F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 81/2 in.

X 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

P-gefof2 FORM HIS-2 (Back)

9. Remarks EXAHINATIONS PERFORNED BY FPL CONSTRUCTION fIC PERSONNEL Applicable Manufacturer's Data Reports to be attached NO MELDING PERFORMED CERTIFICATION OF COMPLIANCE We certify that the statements made in the report are correct and this REPLACEMENT conforms to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N/A Certificate of Authorization No. Expiration Date Signed ,19 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I. the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Dade Coun Florida and employed by Arkwri ht Mutual Insurance Com an of Norwood MA have inspected the components described in this Owner's Report during the period 12/21/92 to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Futhermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Factory Mutual System Commissions I ters gnature National Board, State, Province, and Endorseme ate

Turkey Point Unit 3 1992 Refueling Outage Summary of Visual Examinations and Functional Testing of Snubbers

TABLE OF CONTENTS ABSTRACT ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 3 P ROCEDURES...................................................... 4 EXAMINATION/TESTING................... ~ ~ o e ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ o 5 C ONCLUSION ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ o ~ ~ o ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 17 ACRONYM LIST................................................... 18

ABSTRACT Visual examination and functional testing of Mechanical Shock Arrestors were performed on Unit 3 to satisfy the requirements of ASME Section XI, 1980 Edition, Winter 1981 Addenda and Plant Technical Specifications during the 1992 Refueling Outage. Visual Examination and Functional Testing activities were performed by Siemens Nuclear Power Services, Inc. during the period of September 21, 1992 through October 21, 1992.

PROCEDURES The following Florida Power 6 Light procedures were used to implement the Mechanical Shock Arrestor Surveillance Program.

AP 0190.83 Mechanical Shock Arrestor Surveillance Program AP 0190.85 Functional Testing of Mechanical Shock Arrestors OP 0209.9 Visual Examination of Mechanical Shock Arrestors O-CMM-105.1 Removal and Reinstallation of Mechanical Shock Arrestors The following procedures were utilized by Siemens Nuclear Power Services, Xnc. to perform the Visual Examination and Functional Testing.

SNPS Quality Assurance Manual Rev. 14 SNPS-PP-33 19-TPN Project Plan SNPS-CAL-2.2, Rev. 0 Daily Verification of Test Equipment SNPS-EXM-1.1, Rev. 0 Visual Examination of MSA's SNPS-TST-1.1, Rev. 0 Functional Testing of PSA MSA's SNPS-MNT-3.1, Rev. 0 Disassembly and Repair of PSA MSA's

Examination Testin Visual examination (VT-3, VT-4 hand stroke) were performed on a total of one hundred and eleven (111) snubbers and functional testing was performed on sixteen (16) snubbers.

TAG'ERIAL MODEL SYSTEM VT FT TEST SAMPLE CORRECTIVE ACTION 3-1000 18015 PSA-1 AFW SAT NONE 3-1001 27095 PSA-3 AFW SAT NONE 3- SEE DEV.

SUMMARY

1002 104 PSA-3 AFW SAT 8-PTN-92-3-1002 3-1003 29625 PSA-3 AFW SAT NONE 3-1004 101 PSA-3 FW SAT NONE 3-1005 10035 PSA-35 MS SAT NONE 3-1006 3051 PSA-35 MS SAT NONE 3-1007 4590 PSA-35 MS SAT NONE 3- SEE DEV.

SUMMARY

1008 8084 PSA-35 MS SAT 2-PTN-92-3-1008 3-1009 1203 PSA-35 MS SAT NONE 3- SEE DEV.

SUMMARY

1010 11931 PSA-35 MS SAT SAT YES 1-PTN-92-3-1010 3-1011 12376 PSA-35 MS SAT NONE 3- SEE DEV.

SUMMARY

1012 8086 PSA-35 MS SAT 3-PTN-92-3-1012 3-1013 33624 PSA-1/4 CCW SAT NONE 3-1014 1722 PSA-1/4 RHR SAT NONE

'I 1

TAG'ERIAL MODEL SYSTEM VT FT TEST SAMPLE CORRECTIVE ACTION 3-1015 18009 PSA-10 SIS SAT NONE 3-1016 18012 PSA-1 SIS SAT NONE 3-1017 18003 PSA-1 SIS SAT SAT YES NONE 3-1018 18013 PSA-1 SIS SAT NONE 3-1019 2889 PSA-3 SIS SAT NONE 3-1020 10335 PSA-3 SIS SAT NONE 3-1021 16725 PSA-1/2 SIS SAT NONE 3-1022 18006 PSA-1 RHR SAT NONE 3-1023 23273 PSA-1 RHR SAT NONE 3-1024 17427 PSA-3 RHR SAT NONE 3-1025 10010 PSA-3 SAT. NONE 3- SEE DEV.

SUMMARY

1026 12394 PSA-10 RHR SAT 17-PTN-92-3-1026 3-1027 16237 PSA-10 RHR SAT NONE 3-1028 11135 PSA-10 RHR SAT NONE 3-1029 11330 PSA-10 RHR SAT SAT YES NONE

TAG/ SERIAL g MODEL SYSTEM VT FT TEST SAMPLE CORRECTIVE ACTION 3-1030 11121 PSA-10 RHR SAT NONE 3-1031 27086 PSA-3 SG SAT NONE 3-1032 24410 PSA-3 SG SAT NONE 3-1033 19328 PSA-3 SG SAT NONE 3- INFO 1034 24429A PSA-1 SG SAT SAT TEST NONE 3-1035 19330 PSA-3 SG SAT NONE 3- SEE DEV.

SUMMARY

1036 27100 PSA-3 SG SAT 6-PTN-92-3-1036 3-1037 11922 PSA-35 FW SAT NONE 3-1038 11934 PSA-35 SAT NONE 3-1039 16241 PSA-10 FW SAT NONE 3-1040 16239 PSA-10 FW SAT NONE 3-1041 16234 PSA-10 FW SAT NONE 3-1042 12365 PSA-10 SAT NONE 3-1043 17899 PSA-10 RCS SAT NONE 3-1044 17900 PSA-10 RCS SAT NONE

'I TAG/ SERIAL g MODEL SYSTEM VT FT TEST SAMPLE CORRECTIVE ACTION 3- INFO SEE DEV.

SUMMARY

1045 7782 PSA-10 RCS SAT UNSAT TEST 13-PTN-92-3-1045 3-1046 17903 PSA-10 RCS SAT NONE 3-1047 17902 PSA-10 RCS SAT NONE 3-1048 17904 PSA-10 RCS SAT NONE 3-1049 16245 PSA-10 RCS SAT NONE 3-1050 17906 PSA-10 RCS SAT SAT YES NONE 3-1051 16249 PSA-10 RCS SAT SAT YES NONE 3- SEE DEV.

SUMMARY

1052 16233 PSA-10 RCS SAT SAT YES 14-PTN-92-3-1052 3- SEE DEV.

SUMMARY

1053 2462 PSA-10 RCS SAT 15-PTN-92-3-1053 3-1054 16248 PSA-10 RCS SAT NONE 3-1055 13697 PSA-10 RCS SAT NONE 3-1057 27106 PSA-3 RCS SAT NONE 3-1058 27102 PSA-3 RCS SAT SAT YES NONE 3-1060 19329 PSA-3 RCS SAT NONE 3-1069 27072 PSA-3 RCS SAT NONE

TAG'ERIAL g MODEL SYSTEM FT TEST SAMPLE CORRECTIVE ACTION 3-1070 27079 PSA-3 RCS SAT NONE 3-1071 27069 PSA-3 RCS SAT NONE 3-1072 27073 PSA-3 RCS SAT SAT YES NONE 3-1073 27090 PSA-3 RCS SAT NONE 3-1074 27104 PSA-3 RCS SAT SAT YES NONE 3- SEE DEV.

SUMMARY

1075 18074 PSA-1/2 CVCS SAT 5-PTN-92-3-1075 3-1076 19725 PSA-3 CVCS SAT NONE 3-1077 16230 PSA-10 FW SAT NONE 3-1078 16229 PSA-10 FW SAT NONE 3-1079 10176 PSA-10 FW SAT NONE 3-1080 10173 PSA-10 FW SAT NONE 3- SEE DEV.

SUMMARY

1081 11921 PSA-35 FW SAT 12-PTN-92-3-1081 3-1082 11932 PSA-35 FW SAT NONE 3-1083 11925 PSA-35 FW SAT NONE 3- SEE DEV.

SUMMARY

1084 7000 PSA-35 FW SAT 11-PTN-92-3-1084

TAG'ERIAL MODEL SYSTEM VT FT TEST SAMPLE CORRECTIVE ACTION 3- SEE DEV.

SUMMARY

1091 27087 PSA-3 CVCS SAT 9-PTN-92-3-109 1 3-1092 27105 PSA-3 CVCS SAT NONE 3-1093 27091 PSA-3 CVCS SAT NONE 3- INFO SEE DEV.

SUMMARY

1094 27074 PSA-3 CVCS SAT SAT TEST 10-PTN-92-3-1094 3-1095 16733 PSA-1/2 CCW SAT NONE 3-1096 11993 PSA-1/2 CCW SAT NONE 3-1097 16724 PSA-1/2 CCW SAT NONE 3-1098 33628 PSA-1/4 CCW SAT NONE 3- SEE DEV.

SUMMARY

1099 16727 PSA-1/2 CCW SAT SAT YES 16-PTN-92-3-1099 3-1100 17819 PSA-1/2 WD SAT NONE 3-1101 33626 PSA-1/4 WD SAT NONE 3-1102 29451 PSA-1/4 WD SAT SAT YES NONE 3-1103 11996 PSA-1/2 CVCS SAT NONE 3-1104 24412 PSA-1 CVCS SAT NONE 3-1105 16134 PSA-1 CCW SAT NONE 10

TAG/ SERIAL MODEL SYSTEM VT FT TEST SAMPLE CORRECTIVE ACTION 3-1106 29495 PSA-1/4 CCW SAT NONE 3- INFO SEE DEV.

SUMMARY

1110 16136 PSA-1 CCW SAT SAT TEST 7-PTN-92-3-1110 3-1111 2875 PSA-3 RHR SAT NONE 3-1112 27083 PSA-3 RHR SAT NONE 3-1120 18325 PSA-1/2 CCW SAT NONE 3-1121 24430 PSA-1 CCW SAT SAT YES NONE 3-1123 12988 PSA-35 MS SAT NONE 3- SEE DEV.

SUMMARY

1124 12991 PSA-35 MS SAT 4-PTN-92-3-1124 3-1125 12986 PSA-35 MS SAT NONE 3-1126 12989 PSA-35 MS SAT NONE 3-1127 12990 PSA-35 MS SAT NONE 3-1128 12985, PSA-35 MS SAT NONE 3-1129 12987 PSA-35 MS- SAT NONE 3-1130 17840 PSA-10 MS SAT NONE 3-1131 17837 PSA-10 MS SAT NONE

1 I TAG'- SERIAL g MODEL SYSTEM VT FT TEST SAMPLE CORRECTIVE ACTION 1132 17838 PSA-10 MS SAT NONE 3-1133 13695 PSA-10 MS SAT NONE 3-1134 17836 PSA-10 MS SAT NONE 3-1135 17839 PSA-10 MS SAT NONE 3-1136 19884 PSA-1/2 CVCS SAT NONE 3-1137 19885 PSA-1/2 CVCS SAT NONE DEVIATION REPORT

SUMMARY

Taca ~ 3-1002 DEVIATION g: 8-PTN>>92-3-1002 Int.: 10/2/92 Closed: 10/5/92 CONDITION: Insufficient thread engagement due to excess washers.

DISPOSITION: Remove excess washers and retorque bolts IAW SNPS-MNT-3.1.

STATUS: Complete

~Ta ~ 3-1008 DEVIATION 5: 2-PTN-92-3-1008 Int.: 9/28/92 Closed: 9/29/92 CONDITION: Dislodged spherical bearing.

DISPOSITION: Restake spherical bearing and verify freedom of movement IAW SNPS-MNT-3. 1; STATUS: Complete.

II

~Ta ~ 3-1010 DEVIATION g: 1-PTN-92-3-1010 Int.: 9/28/92 Closed: 9/29/92 CONDITION: Load pin deformed.

DISPOSITION: Replace load pin IAW SNPS-MNT-3.1.

STATUS: Complete.

~Ta ~ 3-1012 DEVIATION g: 3-PTN-92-3-1012 Int.: 9/28/92 Closed: 10/3/92 CONDITION: Worn load pin.

DISPOSITION: Replace load pin IAW SNPS-MNT-3.1.

STATUS: Complete.

~Ta ~ 3-1026 DEVIATION 4: 17-PTN-92-3<<1026 Int.: 10/10/92 Closed: 10/16/92 CONDITION: Valve in contact with TTA.

DISPOSITION: NCR N-92-0237 generated. Final disposition states that valve should be partially throttled until a gap of 1/8 in. is created between valve and transition tube.

STATUS: This action has been completed and valve has been tagged to preclude reoccurrence.

~ac[ Q 3-1036 DEVIATION 4: 6-PTN-92-3-1036 Int.: 9/30/92 Closed: 10/1/92 CONDITION: Insulation resting on snubber and clamp.

DISPOSITION: PWO generated to have insulation trimmed back so as not to have it touch snubber.

STATUS: Complete.

13

~Ta ~ 3-1045 DEVIATION 4: 13-PTN-92-3-1045 Int.: 10/8/92 Closed: 10/8/92 CONDITION: MSA exceeded the specified acceleration criteria (0.02) by 0.002G.

DISPOSITION: NCR N-92-0218 generated. Replace MSA with tested spare S/N 17189.

STATUS: Complete.

~Ta ~ 3-1052 DEVIATION g: 14-PTN-92-3-1052 Int.: 10/8/92 Closed: 10/10/92 CONDITION: Spherical bearing frozen.

DISPOSITION: Clean and lubricate spherical bearing IAW General Maintenance Items for MSA.

STATUS: Complete.

Tac[ ~ 3-1053 DEVIATION g: 15-PTN-92-3-1053 Int.: 10/8/92 Closed: 10/9/92 CONDITION: Insufficient thread engagement on TTA bolts.

DISPOSITION: Replace TTA bolts with correct bolts.

STATUS: Complete.

~Ta ~~ 3-1075 DEVIATION 4: 5-PTN-92-3-1075 Int.: 9/30/92 Closed: 10/1/92 CONDITION "L" dimension less than specified.

DISPOSITION: NCR N-92-0208 generated. Final Disposition stated that snubber was acceptable as is. Repair to this support may be performed no later than next refueling outage.

STATUS: Repair has not yet been performed and is being tracked by commitment ID Number PM92-11-046.

14

Taca ~ 3-1081 DEVIATION g: 12-PTN-92-3-1081 Int.: 10/7/92 Closed: 10/8/92 CONDITION "L" dimension less than specified.

DISPOSITION: NCR N-92-0217 submitted. Acceptable as is. Drawing to be revised.

STATUS: Drawing revision still pending.

~Ta ~ 3-1084 DEVIATION g: 11-PTN-92-3-1084 Int.: 10/6/92 Closed: 10/6/92 CONDITION: Worn load pin.

DISPOSITION: Replace load pin IAW SNPS-MNT-3.1.

STATUS: Complete.

Taca ~ 3-1091 DEVIATION g: 9-PTN-92-3-1091 Int.: 10/2/92 Closed: 10/7/92 CONDITION: Dislodged spherical bearing.

DISPOSITION: Restake spherical bearing and verify freedom of movement IAW SNPS-MNT-3.1.

STATUS: Complete.

~aca + 3-1094 DEVIATION g: 10-PTN-92-3-1094 Int.: 10/5/92 Closed: 10/6/92 CONDITION: MSA was hard to stroke by hand.

DISPOSITION: Functional test, MSA.

STATUS: Functionally tested MSA sat. Reinstalled MSA.

~Ta ~ 3-1099 DEVIATION g: 16-PTN-92-3-1099 Int.: 10/9/92 Closed: 10/10/92 CONDITION: "L" dimension less than specified.

DISPOSITION: NCR N-92-0224 generated. A PSA-1/4 mechanical snubber to be installed which has a longer travel than the present PSA-1/2, thus assuring that the snubber will not bottom out.

STATUS: PSA-1/4 S/N 38481 installed per W092052937. PCM-92-150 issued to revise drawings.

~aca + 3-1110 DEVIATION g: 7-PTN-92-3-1110 Int.: 9/30/92 Closed: 10/9/92 CONDITION: 1) Dislodged spherical bearing.

2) Binding during hand stroking.

DISPOSITION: 1) Restake spherical bearing and verify freedom of movement XAW SNPS-MNT-3.1.

2) Perform functional test.

STATUS: Complete and tested sat.

Taca Q 3-1124 DEVIATION 4: 4-PTN-92-3-1124 Int.: 9/29/92'losed:

10/2/92 CONDITXON: 1) Broken lock ring.

2) Dislodged spherical bearing.

DISPOSITION: 1) Replace lock ring XAW General Maintenance Items for MSA.

2) Restake spherical bearing and verify freedom of movement IAW SNPS-MNT-3.1.

STATUS: Complete.

16

CONCLUSION During the 1992 Refueling Outage, snubber surveillances were performed on the snubber population of Turkey Point. Unit 3 in accordance with AP 0190.83 (Mechanical Shock Arrestor Surveillance Program). These surveillances included visual examinations and hand stroking of all Unit 3 snubbers in accordance with OP 0209.9 (Visual Examination of Mechanical Shock Arrestors). The functional test representative sample, and additional selections were tested and selected in accordance with AP 0190.85 (Functional Testing of Mechanical Shock Arrestors).

All functional tests and visual examinations were performed in compliance with ASME Section XI and the surveillance requirements of Plant Technical Specifications (3/4.7.6). Visual examinations did not reveal any items that would render the snubber non-functional, therefore there were no failures. Of the snubbers that were functional tested, there were no failures of the test sample. One functional test failure did occur on a snubber tested for information only.

Therefore, FPL has met all ASME Section XI and Plant Technical Specification requirements for visual examination and functional testing of snubbers at Turkey Point. Unit 3.

17

A r

ACRONYM LIST The following Summary:

is a list of all acronyms used in this Snubber ASME American Society of Mechanical Engineers AP Administrative Procedure OP Operating Procedure CMM Corrective Maintenance Mechanical SNPS Siemens Nuclear Power Services PP Project Plan CAL Calibration EXM Examination TST Testing MNT Maintenance Rev. Revision Inc. Incorporated PSA Pacific Scientific Arrestors MSA Mechanical Shock Arrestor's AFW Auxiliary Feedwater FW Feedwater MS Main Steam CCW Component Cooling Water VT Visual Test FT Functional Test SAT Satisfactory DEV Deviation PTN Turkey Point Nuclear RHR Residual Heat Removal SIS Safety Injection System SG Steam Generator RCS Reactor Coolant System INFO Information CVCS Chemical and Volume Control System WD Waste Disposal Int. Initiated TTA Transition Tube Assembly NCR Non-Conformance Report PWO Plant Work Order S/N It Lll Serial Number Length PCM Plant Change Modification FPL Florida Power & Light IAW In Accordance With 18

4.

Turkey Point Unit 3 1992 Refueling Outage Summary Tables of Inservice Inspection Examinations

DATE:I 03/OB/93 TURKEY POIHT NUCLEAR PLANT UNIT 3 PAGE:

I SION:T 1 INSERVICE INSPECTION

SUMMARY

SECOND IHTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 1 ALL STATUS COMPONENTS STEAN GEMERATOR A PRIMARY SID H I 0 ZONE NUMBER: 003 ASHE S OMGT SEC. Xl RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEN MO METHOD PROCEDURE T C G H R ~~CALIBRATIOH BLOCK~~

REF. DLIG. HO. 3.V09A 039910 3-SGA-SUPPORT F-A VT 1 4.1 '7 A X... 10/26/92 - VT COMPLETE( SUPPORT LEG HUTS FOUR SUPPORT LEGS F1.10 ONLY CTHT

  • ON/At~

C i

DATE: 03/08/93 TURKET POINT NUCLEAR PLANT UHIT 3 PAGE: 4 I SION! 1 IHSERVI CE INSPECTION SUHHART SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE <92RF)

CLASS 1 ALL STATUS COHPOHENIS R ACTOR COOLANT S'TS'TEH LOOP A COLO LEG N I ZOHE NUHBER: 009 ASHE S ONG SEC. XI T RSE H SUHHART EXAHIHAT ION AREA CATGT EXAH A E I 0 E REHARKS NUHBER IDENT IF I CAT IOH ITEH NO HETHCO PROCEDURE CGH R

  • CALIBRATIOH BLOCK**

TST H NO. 41 5613 '-766-S SH 1 OF 1 REF. DUG. NO. 3-A03 046000 27.5".RCS.1307-14 B-F PT NDE 3.3-16 C X - - - 11/4/92 PT COHPLETEI UT PERFORHED ELBOM TO RPV NOZZLE B5.10 UT HDE 5.11 DURIHG THE PREVIOUS OUTAGE, LIHITED CTHE 25'6't EXAHINATION DUE TO NOH.REHDVABLE INSULATIOH AND LIHITEO ACCESS INSIDE SANDBOX ttUT 3241

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 PAGE: 5 REVI SIOM. 1 INSERVICE INSPECTIOM

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 1 ALL STATUS CONPONEHTS T ANT SYSTEH OOP B COLD LE N I 0 ZOHE NUMBER: 012 ASHE S OHGT SEC. XI 1 RSEH SQDIARY EXANINATI ON AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEN NO METHOD PROCEDURE r C G H R "CALIBRATIOM BLOCK*'STEII NO. 41 5613 P 766 S SH. 1 OF 1 REF. DLIG. NO. 3-A06 048600 27.5".RCS-1306-14 BF PT HDE 3.3.17 C X - ~

11/4/92 - PT CONPLETE, UT PERFORMED ELBSJ TO RPV NOZZLE B5.10 UT NDE 5 ~ 11 DURING PREVIOUS OUTAGE, LIMITED CTIIT, 25'6" EXAMINATION DUE TO MOH REMOVABLE IHSULATIOM AND LIMITED ACCESS IN SANDBOX

~~UT-32~*

DATE: 03/08/93 TURKEY POINT NUCLEAR'LANT UHlt 3 PAGE: 6 IS IOI: 1 INSERVICE INSPECTION SUHHART SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 1 ALL StATUS COMPONENTS REACT COOLANT SYSTEH LOOP C COLO LEG H I 0 ZONE NUHBER: 015 ASHE S ONGT SEC. XI RSEH SUMHARY EXAHI NATION AREA CATGY EXAH A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE I C G H R CALIBRATION BLOCK YSTEM NO. C1 5613-P 766 S SH. 1 OF 1 REF. DUG. NO. 3 A09 051000 2r.5 -RCS-1309-1C BF Pt NDE 3.3 18 C X - .. 11/C/92 . PT CCMPLETE, UT PERFORHED ELBOM TO RPV NOZZLE 85.10 UT NDE 5.11 DURING THE PREVIOUS OUTAGE, LIHITED CTHT, 25'8" EXAHINATION DUE TO NON REMOVABLE INSULATIOH AHD LIHITED ACCESS IN SANDBOX

~ tUT 32*t

e DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 PAGE: 7 REV I SIGH: 1 INSERVICE INSPECTION SUNNARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 1 ALL STATUS COHPOHENTS ACTOR LANT SYS'I N PRESSURI2ER SURG L N H I 0 ZONE HUNBER: 016 ASKE S ONGT SEC. XI T RSEH SUHHARY EXANIHAT ION AREA CATGY EXAH A E I 0 E REMARKS NUNBER IDENT IF I CAT ION ITEN NO NETHOO PROCEDURE C G N R *~CALIBRATIOH BLOCK~~

SYSTEH NO. 41 5613 P-766-S SH. 1 OF 1 REF. DMG. NO. 3-A10 051800 VS.1G-12 F-C VT-3 H92-0262 A X - - 92 BASELINE EXAHINATIOH COHPLETE(

DUAL SPRING HANGER F3.50 VT-3 H92-0253 X ~ - SPRING HANGER REPLACED DURING OUTAGE CTIIT, 25'8" PC/N 91-199 CMO 500789

~~N/A~~

051900 VS. I G.12 1A PT K-92-0257 C X ~

92 ~ RENOVEO FRON SERVICE DURING THE IN'TEGRAL ATTACHNEHTS PC/II 91-199 1992 OUTAGE, PT PERFORNED OH AREASMHERE CTNT, 25'8" CMO 500789 MELDS MERE RENOVED

  • ~N/A~~

DATE: 03/08/93 TURKEY POINT NUCLEAR PLAMT UMIT 3 PAGE: 8 I SION: 1 INSERVICE INSPECTIOH

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 1 ALL STATUS COMPONENTS EACT OOLANT SYSTEM PRESSURIZER SAFETY OOP B H I 0 ZONE NUMBER: 018 ASHE S OM0T SEC. XI T RSEH SUWQRY EXAHINATIOH AREA CATGY EXAM A E I 0 E REMARKS NLNBER IDEHT IF ICATION ITEM NO METHOD PROCEDURE T C G H R ~~CALIBRATION BLOCKi~

S'YSTEH NO. 41 5613.P 660 S SM. 3 OF 3 REF. DIJG. NO. 3-A12 054100 4".RC-1302-1A BF RT TECH 9.3 C X - - 10/24/92 RT COMPLETE, PT AND UT 3.3 NOZZLE TO SAFE END CTHT B5.40 UI'DE PT HDE 5.4 PERHORHED DURING PREVIOUS OUTAGE, RT PERFORMED COVERAGE TO OBTAN CDHPLETE CODE i~UT.SP*

DATE: 03/08/93 IURKEY POINT HUCLEAR PLANT UNIT 3 PAGE: 9 EV I SION: 1 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 1 ALL STATUS COMPONENTS ACTOR COOLAHT SYST M PRESSURIZER SAFETY LOOP C N I 0 ZONE NUMBER: 019 ASHE S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT I F I CAT ION ITEN NO HE'THOO PROCEDURE T C G H R *~CALIBRATION BLOCK~*

SYSTEM NO. 41 5613.P.660.S SH. 2 OF 3 REF. DNG. MO. 3-A13 055500 4"-RC-1303-1A B.F RT TECH. 9.3 C X - - - 10/24/92 ~ RT COMPLETE, PT AND UT NOZZLE TO SAFE END B5.40 PT NDE 3.3 PERFORMED DURING PREVIOUS OUTAGE, RT CTHT UT NDE 5.4 PERFORMED TO OBTAIN COMPLETE CODE COVERAGE otUT 53**

OATE: 03/08/93 TURKEY POINT NUCLEAR PLANt UNIT 3 PAGE: 10 VISION: IMSERVICE IMSPECtlON SUHHARY SECONO INTERVAL, TNIRO PERIOO, SECONO OUTAGE (92RF)

CLASS 1 ALL STATUS COHPONENTS CTOR COOLAMT SYSTEH PRESSURIZER SPRAY 1'0 PRZ.

M I 0 ZONE MUHBER: 020 ASNE S OMGT SEC. XI T RSEN SIHHARY EXAHIMAT ION AREA CATGY EXAH A E I 0 E REHARKS NUHBER IDENTIFICATION ITEH NO HETNOO PROCEOURE T C G H R *~CALIBRATION BLOCK~~

YSTEH NO. 41 S 47 5613 P 661-S SN. 4 OF 4 REF. OWG. NO. 3-A14 061700 4"-RC-1304-23 8-J Pt NDE 3.3.7 C X... 10/14/92 - Pt COHPLETE; UT COHPLETEO ELBOJ TO BENT PIPE B9.11 UT NDE 5.4 DURING PREVIOUS OUTAGE CTHT

~~UT.53**

062100 4".RC-1304-1A B-F Pt NOE 3.3.7 C X - - - 10/14/92 - PT COHPLETE; 10/24/92 . Rt SAFE-ENO TO NOZZLE 85.40 Rt TECH. 9.3 X COMPLETE, ACCEPTABLE POROSITY CTHT aaUT-53am

DATE: 03/08/93 TURKEY POINT NUCLEAR PLAMT UMII' PAGE: 11 IS IOH: 1 IHSERVICE INSPECTION

SUMMARY

SECOHD INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 1 ALL STATUS COMPONENTS X L ARY SPRAY LINE H I 0 ZONE NUMBER: 035 ASHE S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEN NO METHOD PROCEDURE t C G H R ~~CALIBRATION BLOCKi~

SYSTEM NO. 41 8 47 5613 P 661.S SH. 2 OF 4 REF. DWG. HO. 3-A31 114300 2".RC-1310.1 BE J PT HDE 3.3-8 A X - - 10/14/92 . Pt COMPLETE, 10/16/92 - Ut REDUCING TEE TO PIPE 89.40 Ut 45 HDE 5.19.1 X - COMPLETE, ROOT AND CORHER GEOMETRY CTHT Ur 70 HDE 5.19-1 ~ X-14UT 540t 114400 2".RC-1310-2 8 J Pt NDE 3.3.8 A X - - - 10/14/92 - Pt COHPLETEI 10/16/92 . Ut PIPE TO VALVE 3.313 89.40 UT 45 HDE 5. 19 1 X COHPLETEi ROOT AND CORNER GEOMETRY CTFIT UT 70 NDE 5.19-1 - X-

  • +Ut-54**

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 VISION 1 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, tNIRO PERIOD, SECOND OUTAGE (92RF)

CLASS 1 ALL STAtUS COHPOMEHTS GH HEAD SAFETY INJECTION LOOP A INSIDE C'IHT N I 0 ZONE NUMBER: 040 ASHE S OM6 SEC. XI T RSEN SUHHARY EXAHINATION AREA CATGY EXAM A E I 0 E REHARKS NUHBER IDENT I F I CAT ION ITEN MO HEtHOO PROCEDURE 'I C G H R CALIBRATIOM BLOCK SYSTEH NO. 62 5613.P-583-S SH. 1 OF 1 REF. DNG. NO. 3.A39 138700 2"-S1-1301-25 8-J PT NDE 3.3.1 C X... 10/9/92 - PT COMPLETE PIPE TO ELBOM 89.21 CTHT

  • tN/AOk 138800 2w Sl 1301-26 8-J PT NDE 3.3.1 C X - ~ - 10/9/92 - PT COHPLETE ELBQI TO PIPE 89.21 CTHT

%AN/A0*

DATE: 03/08/93 TURKEY POIHT NUCLEAR PLANT UHIT 3 VI SION: 1 INSERVICE INSPECT IOH SUHHARY SECOND INTERVAL~ THIRD PER I 00 'ECOND CUTAGE (92RF )

CLASS 1 ALL STATUS COMPONENTS H HEAD SAFETY MJECT OM LOOP 8 MSIDE CTHT H I 0 20ME NUMBER: 041 ASHE S ONGT SEC. XI T RSEH SIRQIARY EXAHIHAT IOH AREA CATGY EXAH A E I 0 E REMARKS MUHBER IDENTIFICATION ITEH NO NETKOO PROCEDURE I C G H R **CALIBRATIOHBLOCK~*

SYSTEH MO. 62 5613 'E 584-S SH. 1 OF 1 REF. DUG. NO. 3-A40 144100 2"-Sl-1302-28 BJ PT NDE 3.3.13 C X . - . 10/26/92 - PT CCHPLETE PIPE TO BRAHCH CONNEC'TIOM 89.21 CTHT

  • ~N/A~~

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 PAGE: 14 EV IS IOH: 1 INSERVICE IHSPECtION SUHHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 1 ALL STATUS COMPONENTS HICAL 8 VOLTE CONTROL TO RC LOOP C MOT LEG N I 0 ZONE NQIBER: 045 ASME S OHGT SEC. XI T RSEN SUHHARY EXAHIHAT ION AREA CATGY EXAH ,A E I 0 E REMARKS NUHBER IDENT I F I CAT ION ITEN NO HETHCO PROCEDURE T C G H R <<<<CALIBRATIOH BLOCK<<<<

SYSTEH NO. 41 8 4T 5613 '.661.S SH. 2 OF 4 REF. DWG. NO. 3-A44 163400 34-CH-1301-28 8 ' Pt NDE 3.3.5 C X ~ - 10/14/92 - PT COHPLETE PIPE TO ELBOll 89.21 CTHT

<<<<N/A<<<<

165800 34-CH.1301-42 8 J Pt NDE 3.3 ~ 12 A X - . - 10/21/92 - Pt COMPLETE; 10/26/92 - Ut PIPE TO ELBOM 89.21 Ut 45 NDE 5.4 2 - X - CCHPLEtE, ROOt AND COUNTERBORE GEOMETRY)

CTHT UT 60 NDE 5.4.2 X 88 08 EXAMINATION

<<*N/A<<<<

165900 34-CH.1301-43 8-J Pt NDE 3.3 12 A X - 10/21/92 - Pt COHPLETE; 10/26/92 - UT ELBOM TO PIPE 89.21 Ut 45 NDE 5.4-2 - X . COMPLETE, ROOT AND COUNTERBORE CTHT UT 60 NDE 5.4.2 - X - GEOMEHTRY 88-08 EXAHINATIOH

<<<<N/A<<<<

DATE: 03/08/93 TURKEY POINT HUCLEAR PLANT UNII 3 REVISION: 1 INSERVICE INSPECTION SUNKARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 1 ALL STATUS COHPOHEHTS A VO UNE OHTRO T RC OOP A LEG H I 0 ZONE NUHBER: 046 ASHE S OHGT SEC. XI T RSEH SUWRY EXAHINATION AREA CAI'GY EXAN A E I 0 E REHARKS NUNBER I DENT IF I CA'T ION ITEN NO HETHDO PROCEDURE T C G H R ~~CALIBRATIOH BLOCKi v

Y HACH-1302-2 T H NO 41 B 47 613.P- 1-S SH. 3 OF 4 REF. DHG. HO. 3.A45 166600 3" BJ PT NDE 3.3.4 C X - - . 10/12/92 - PT CONPLETE PIPE TO ELBOM 89.21 CTHT

~~N/A~*

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 VIS IOH: 1 IHSERV ICE INSPECTION SUHMARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 1 ALL STATUS COHPONEHTS NEHICA AND VOLUME CONTROL TO REGENERATIVE HX H I 0 ZONE HUHBER: 047 ASNE S OHGT SEC. XI RSEH SUNHARY EXAHIHATIOH AREA CAI'GY EXAH A E I 0 E REHARKS NINBER IDEHTIFICATION ITEN NO HETHCO PROCEDURE C G H R ~*CALIBRATION BLOCK+~

SYSTEN NO. 47 5613-P-594-S SH. 1 OF 1 REF. DWG. NO. 3-A46 172100 3"-CH-1303-9 8-J PT NDE 3.3.6 C X - - . 10/14/92 - PT CONPLETE PIPE TO ELBOM 89.21 CTHT

    • N/A~~

172200 3"-CN-1303-10 BJ PT NDE 3.3.5 C X - - - 10/14/92 - Pr CONPLETE ELBOM TO PIPE 89.21 CTHT tkN/A*A

DATEs 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 I SION 1 IHSERVICE INSPECT IOH SUHHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUIAGE (92RF)

CLASS 1 ALL STATUS COHPOHEHTS EH COHTRO FR TH REGENERAT V HX H I 0 ZOHE NUHBERs 049 ASHE S ONGT SEC. XI T RSEH SUHHARY EXAHI NATION AREA CATGY EXAM A E I 0 E REHARKS C G H R ~ ~CALIBRATIOH BLOCK**

NUNBER IDENT IF ICATION ITEN NO HETHOO PROCEDURE T SYSTEH NO. C7 5613.P.644-S SN. 2 OF C REF. DUG. NO. 3-ACB 179800 24-CH-1302-28 BJ PT NDE 3.3.3 C X - - ~ 10/9/92 . Pl'ONPLETE PIPE TO ELBQI B9.21 CTHT

~~N/A~~

179900 2"-CH-1302-29 B-J PT NDE 3.3-3 C X - - 10/9/92 . PT COHPLETE ELBOM TO PIPE B9.21 CTHT 180600 24-CH-1302-34 B J P'I HDE 3.3.3 C X . - . 10/9/92 - PT COHPLETE PIPE TO ELBOM B9.21 CTHT

  • fN/A4*

BJ PT NDE 3.3-3 C X . . 10/9/92 . PT COHPLETE ELBOM TO PIPE 89.21 CTHT N/A~~

DATE: 03/08/93 TURKEY POIHt NUCLEAR PLANt UNIT 3 PAGE: 1B REVISION: 1 INSERVICE INSPECTION

SUMMARY

SFCOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 1 ALL STATUS COHPONEHTS TOR LANT PUMP N I 0 ZONE MISBER: 057 ASHE S OMGT SEC. XI I RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS HISSER IDENT IF I CATION ITEM NO METHOD PROCEDURE T C G M R ~~CALIBRATIOH BLOCK

  • SYSTEM NO. 41 REF. DUG. HO. 3-V138 202600 3.RCP-FLB-1 THRU 24 B.G.1 VT-1 NDE 4.1-1 C X . - - 10/12/92 - Vt COMPLETE( EXAMINED MltH 17 FLANGE SURFACE B6.190 StUDS AND 3 GUIDE PINS INSTALLED CTMT 8 0 H/Ao 4 202700 3-RCP-8-FLYNEEL RG1.14 PT I SI.11 C X - . 3/10/92 EXAMINATIONS PERFORMED BY FLYMHEEL UT IS I.41 X - - . MESTINGHOUSE( SURFACE AND VOLUMETRIC CTHT EXAHS COMPLETED IH ACCORDANCE MITH REG.

GUIDE 1.14

~~FLYMHEEL~~

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 EVI SION: 1 IHSERVICE INSPECTION SUNNARY SECOND INTERVAL, THIRD PERIOD, SECOHD OUTAGE (92RF)

CLASS 1 ALL STA'IUS CONPONENTS ACTOR OO AHT PUNP H I 0 ZONE NUHBERI 058 ASNE S ONGT SEC. XI T RSEH SUNNARY EXANI NATION AREA CATGY EXAN A E I 0 E RENARKS NUNBER IDENT IF I CAT IOH ITEN NO HETHOO PROCEDURE C G N R ~~CALIBRATION BLOCK~~

SYSTEN NO. C1 REF. DMG. NO. 3-V13C 203800 3-RCP-C-FLYMHEEL RG1.14 UT 10 NDE 5.15 I C X - - - 10/21/92 . UT CONPLETE FLYMHEEL CTHT

~~FLYMHEEL~~

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 PAGE: 20 R VISION: 1 INSERVICE INSPECTIOH SUNNARY SECOND INTERVAL, THIRD PERIOD, SECOHD OUTAGE (92RF)

CLASS 'I ALL STATUS COHPOHENTS NERAT VE HEAT EXCHANGER H I 0 ZONE NUHBER: 059 ASNE S OHGT SEC. XI RSEH SUHHARY EXAHIHATION AREA CATGY EXAH A E I 0 E REHARKS PROCEDURE 0 H CALIBRATIOH BLOCK

  • NUHBER IDEHT IF I CAT IOH ITEN NO METHOD T C R REF. DWG. NO. 3-V11 209200 RGX 3E200 VT-2 NDE 4.2-1 C X - - - 10/15/92 . VT.3 COHPLETE; 11/25/92 .

VISUALS FOR LEAKAGE VT 3 NDE 4.3-31 X - . - VT-2 COHPLE'IE CTHT ttH/Att

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UHIT 3 EV I SION: 1 IMSERVICE INSPECTION SUWRY SECOND INTERVAL, THIRD PERIOD, SECOHD OUTAGE (92RF)

CLASS 2 ALL StATUS COMPONENTS AM G NERATOR A SECONDARY SID N I 0 ZONE NUMBER: 060 ASME S OHGT SEC. XI T RSEH

SUMMARY

EXAIIINAYION AREA CAtGY EXAM A E I 0 E REMARKS NUMBER I I DENT IF CATION ITEM MO METHOD PROCEDURE 1 C G H R CALIBRATION BLOCK REF. DUG. NO. 3-VIOA 210500 3.SGA-SS VT MDE 4.4-2 C X 10/7/92 - VT COMPLETE SECONDARY SlOE EXAMINATION CTIIT 4tH/Akt

TURKEY POINT NUCLEAR PLANT UNIT 3 PAGE: 22 DATE: 03/08/93 EV I S I OH: 1 INSERVICE INSPECtlOH SUHNARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 2 ALL StATUS COMPONENTS AH GEHERATOR B SECONDARY S D N I 0 ZONE HUNBER: 061 ASNE S ONGT SEC. XI T RSEH SUHHARY EXAHIHATION AREA CATGY EXAII A E I 0 E REHARKS NUHBER IDEN'I IF I CAT ION ITEN NO NETHOO PROCEDURE C G N R i*CALIBRATION BLOCK*i REF DUG. NO. 3-V10B 210900 3-SGB.CL C-A UT 0 HDE 5.1-1 C X . ~

10/21/92 . UT COHPLETE, INSIDE SURFACE TRANSITION TO UPPER SHELL llELD C1.10 UT 45 NDE 5.1 1 -XX GEOHETRY, ACCEP'TABLE SLAG CTHT UT 60 NDE 5.1-1 -XX Ut 70*

211600 3.SGB-SS VT NDE 4.4-1 C - X 10/6/92 - VT COHPLETE, DEBRIS FOUND SECONDARY SlOE EXAIIINATION --- CNR 92.3.016 INSIDE STEAN GENERATOR ON UPPER LEDGE; CTNT DEBRIS WAS REHOVED

~~H/A~~

DATES 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 REVISION: 1 INSERVICE IHSPECTIOH

SUMMARY

SECOHD INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 2 ALL STATUS COMPONENTS N RATOR C SECONDARY S M I 0 ZONE NUMBER: 062 ASHE S ONGT SEC. XI T RSEH

SUMMARY

EXAMIMATI OH AREA CATGY EXAM A E I 0 E REMARKS ITEN METHOD PROCEDURE C G M R ~~CAL IBRATIOH BLOCK~~

NUMBER IDENT IF I CAT IOM HO R F DUG. MO. 3-V10C 212610 3.SGC-SS VT NDE 4.4.3 C X - - - 10/7/92 - VT COMPLETE SIDE EXAMINATION

'ECONDARY CTHT tlN/Akk

DATE: 03/08/93 TURKEY POIHT NUCLEAR PLANT UNIT 3 PAGE: 24 REVI SION: 1 IHSERVICE INSPECTION SUHHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 2 ALL STATUS COHPONEHTS ASS P H I ZONE HINBERT ASHE S OHG SEC. Xl T RSE SUHHARY EXAHINATI OH AREA CATG'Y EXAH A E I 0 E REMARKS HUHBER IDENT IF ICATION ITEN NO HETHOO PROCEDURE T CGH R ~*CALIBRATIOH BLOCK REF OlÃ. HO. 3-V19C 212720 RHR PUHP 3P210A VT.1 NDE 4. 1-15 C . . - X 10/21/92 ~ VT COHPLETE, LEAKAGE AT CHR 92 '-045 FLANGE, ACCEPTED AS IS, lllLL BE Puo 92047232 CORREC'IED UNDER A PQO At A FUTURE OAtE REF. OMG. NO. 3.V190 212730 RHR PUHP 3P210B VT 1 NDE 4.1-16 C - - X 10/21/92 ~ VT COHPLETE, LEAKAGE AT CNR 92-3.046 FLANGE, ACCEPTEO AS IS, HILL BE PWO 92047261 CORRECTED UNDER A PlO AT A FUTURE DATE

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 PAGE: 25 REVI SION: 1 IHSERVICE INSPECTION SUHHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 2 ALL Sl'ATUS COHPOHENTS UA HEAT RENOVAL SYSTEH FRON AC UHULATOR B N I 0 ZONE NUNBER: 079 ASHE S OHG I SEC ~ XI T RSEH SUHMARY EXANIHAT I OH AREA CATGY EXAN A E I 0 E REHARKS NUNBER IDENTIFICATION ITEN NO NETHOD PROCEDURE T C G H R ~~CALIBRATIOH BLOCK~~

SYSTEN HO. 50 5613-P-586-S SH. 1 OF 1 REF. OMG. NO. 3-B16 251200 3-SIN.100 F.C VT-3 NDE 4.3-24 C - X 10/8/92 VT COMPLETELY GAP BETMEEH SPRING HAHGER F3.50 CHR 92-3.021 BASEPLATE AHD 'MALL, ACCEPTED AS IS BY CTNT, 21<4 NCR N-92-0234 ENGINEERING EVALUATION 1~N/Aos 251300 3 SIH 100 IA C-C PT NDE 3.3.2 C X . . - 10/9/92 ~ PT COMPLETE INTEGRAL ATTACHHENT C3.20 CTIIT~ 21 '4"

<<"k/A*~

DATE: 03/08/93 TURKE'Y POINT NUCLEAR PLANT UNIT 3 PACE: 26 REV I SION: 1 INSERVICE INSPECTIOH

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTACE (92RF)

CLASS 2 ALL S'IATUS COMPONENTS DUAL NEAT REMOVAL SYSTEH FROM ACCUMULATOR C N I 0 ZONE NUHBER: 080 ASME S ONGT SEC. XI T RSEN

SUMMARY

EXAHIHAT ION AREA CATGY EXAH A E I 0 E REMARKS NUMBER IDENT IF I CAT ION ITEM NO METHOD PROCEDURE C G H R ~*CALIBRATION BLOCK*~

SYSTEM NO. 50 5613-P 587 S SM. 2 OF 2 REF. DUO. NO. 3.B17 251700 10".Sl-2303-1 C-F PT NDE 3.3-9 C X - ~ . 10/14/92 . PT COMPLETE NOZZLE TO PIPE C5 ~ 11 CTHT WIN/A11 251800 104-SI -2303-2 C-F PT NDE 3.3-9 C X - ~ 10/14/92 PT COHPLETE PIPE TO PIPE C5.11 CTHT

~~N/A~~

251900 10"-S I -2303-3 C.F PT NDE 3.3-9 C X - 10/14/92 - PT COMPLETE PIPE TO PIPE C5.11 CTHT

~~N/A*~

0 10"-Sl-2303-4 C.F PI NDE 3.3.10 C . - X 10/14/92 - PI'OMPLETEI 4 LINEAR PIPE TO ELBCM C5.11 CNR 92.3.027 INDICATIONS AT THE DOQISTREAH TOE OF THE CTHT NCR N.92-0252 VELD, DETERHINED TO BE LAP UPSET FROM PQO 92052750 CONSTRUCTION, INDICATIONS REHOVED AFTER SURFACE PREPARATION 11N/AOO 252100 10".Sl-2303.5 C-F PT NDE 3.3.9 C X ~ - 10/14/92 - PT COMPLETE ELB04I'TO VALVE 3-865C C5 ~ 21 CTHT ttN/Aft

OATE: 03/08/93 TURKEY POINT HUCLEAR PLANI'NIT 3 PAGE: 27 REVISIOH: 1 IHSERVICE INSPECTIOH SUMHARY SECOHO IHIERVAL, THIRD PERIOO, SECOND OUTAGE (92RF)

CLASS 2 ALL STATUS COMPONENTS OUA HEAT REHOVAL SYSTEH IHSIOE COHTAINHEHT H I 0 ZONE NUHBER: 089 ~ ASHE S OHGT SEC. XI T RSEH SUMHARY EXAHIHATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IOEHTIF I CAT ION ITEH NO KETHOO PROCEOURE T C G H R ~~CALISRATIOH BLOCK~~

SYSTEM NO. 50 5613.P-587 S SH 1 OF 2 REF. DMG. NO. 3-B27 267940 3-89-A1 F-B VT-3 NDE 4.3-35 C X - 10/20/92 - VT COHPLETE ANCHOR F2.10 CTHT, 26'0"

~~UT 41*~

267980 3-89.A1 IA C.C PT NOE 3.3-11 C . X 10/20/92 . PT COMPLETE, LINEAR INTEGRAL ATTACHMENT C2.30 CHR 92-3.042 IHOICATIOHS, OETERHIHEO TO SE LAP UPSET CTHT, 26'0" HCR N.92.0262 FROM CONSTRUCT IOH, IHDICAT IOHS MERE PHO 92053480 REHOVEO AFTER SURFACE PREPARATION

    • N/A*~

DA'TE: 03/08/93 TURKET POler NUCLEAR PLANT UNIT 3 PAGE: 28 REVI S IOH: 1 INSERVICE INSPECTION SUHHART SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 2 ALL STATUS CCHPONENTS T AH Y T H OOP NS E ONTA NHENT N I 0 2ONE NUHBER: 097 ASHE S ONG1 SEC. XI T RSEK SUHHARY EXAHIHAT ION AREA CATGY EXAH A E I 0 E REHARKS NUHBER IDENT I F ICATION ITEH NO HETKOO PROCEDURE T C G H R ttCALIBRATION BLOCKtt STSTEH NO. 72 613-P 656 S SK. 1 OF 1 REF ~ DMG NO. 3 857 293600 3-97-A1 F-8 VT.3 NDE 4.3.27 C X .. 10/20/92 . VT COHPLETE ANCKOR F2. 10 CTHT 8 54 I 10'I ttN/Att 3-97-A1 IA CC HT NDE 2.2.1 C X - - . 10/12/92 - HT COHPLETE, LIHITED EXAH DUE 293650 INTEGRAL ATTACKHENT C2.30 TO RT PLUG CTHT, 54'10" ttN/Att

J L

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 PAGE: 29 REVISION: 1 INSERVICE INSPECTION SUHHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 2 ALL STATUS COHPONENTS ST AH SYSTEH LOOP B INSIDE CONTAINHENT N I 0 ZONE NUHBER: 098 ASHE S ONGI SEC. XI RSEN SUHHARY EXAHINATION AREA CATGY EXAH A E I 0 E REHARKS NUHBER IDENTIFICATION ll'EH NO HETHOO PROCEDURE T C G H R ~~CALIBRATION BLOCK~~

YST H N . 72 61 -P.6 7-S SN. 1 OF 1 REF. DUG. NO. 3.B59 296540 3-98.A1 F-B VT-3 NDE 4.3-32 C X - - - 10/13/92 - VT COHPLETE ANCKOR F2.10 CTHT, 54'10"

  • ~N/A~~

296580 3-98-A1 I A C-C Hr NDE 2.2.2 C X - - . 10/12/92 . HT COHPLETE INTEGRAL ATTACNHENT C2.30 CTHT, 54'10" WAN/Att

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 REVI S IOH: 1 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 2 ALL STATUS COMPONENTS N RATOR A B OLSOUH NS DE HTA NMENT N I 0 ZONE NUMBER: 103 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R ~~CALIBRATION BLOCK~~

SYSTEM NO. 71 5613-P-795.S SH 2 OF 2 REF. DUG. NO. 3.B72 313950 78101 8.H.320-09 I A C-C MT NDE 2.2.7 C X - - - 10/20/92 - MT COMPLETE INTEGRAL ATTACHMENT C3.20 CTMT, 32'6"

~~H/A~~

SYSTEM NO. 71 5613 P 795 S SH. 1 OF 2 REF. DUG. NO. 3.B72 315750 78101B-H-320 04 IA C.C MT NDE 2.2.6 C X - .. 10/15/92 - MT COMPLETE INTEGRAL ATTACHMENT C3.20 CTMT, 22'04

~"N/A~~

316150 781018-H-320.02 IA C-C MT NDE 2.2.6 C X - - - 10/15/92 - MT COMPLETE INTEGRAL ATTACHMENTS C3.20

DATE: 03/08/93 'TURKEY POINT NUCLEAR PLANT UHIT 3 PAGE: 32 REVISION: 1 IHSERVICE IHSPECTIOH SUHHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 2 ALL STATUS COHPONEHTS AH EMERATOR BLQJDOLIM NSID MTAINHEHT N I 0 ZONE NUHBER: 105 ASHE S OH 0T SEC. XI T RSEH SUHHARY EXAHINATION AREA CATGY EXAM A E I 0 E REHARKS NUMBER IDENT IF I CATION ITEH NO METHOD PROCEDURE T C 0 H R ~*CALIBRATIOH BLOCK ~

SYSTEH MO. 71 5613-P-797-S SH. 3 OF 3 REF. DUG. NO. 3-B76 319600 781018- H.322-09 IA C-C HT NDE 2.2 8 C X - - - 10/20/92 - HT COHPLETE INTEGRAL ATTACHMENT C3.20 CTHT, 33'14

  • ~M/A*1 SYSTEH MO. 71 5613 P 797-S SH. 2 OF 3 REF. DUG. NO. 3 B76 321300 781018-H-322-05 IA C.C HT NDE 2.2 8 C X . . . 10/20/92 . HT COMPLETE INTEGRAL ATTACHHENT C3.20 CTHT, 21'8" 1 0M/A14 SYSTEH NO. 7'I 5613.P-797-S SH. 1 OF 3 REF. DIC. NO. 3.B76 322400 781018-H-322-03 IA C-C HT NDE 2.2.8 C X - - ~

10/20/92 ~ HT COHPLETE INTEGRAL ATTACHMENT C3.20 CTHT~ 25'6"

    • H/A~~

322900 78101B- H-322-02 I A C.C HT HDE 2.2.8 C X . . . 10/20/92 . HT COHPLETE INTEGRAL ATTACHMENT C3.20 CTHT, 24'9"

~~N/A~~

DATE: 03/08/93 TURKEY POIHT NUCLEAR PLANT UNIT 3 REVISION: 1 IHSERVICE INSPEC'I ION SUHHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 2 ALL STATUS CONPOHENTS GENERATOR 8 BLOM)OMH INSIDE COHTAINNEHT N I 0 ZONE NUNBER: 104 ASHE S ONGT SEC. XI 1 RSEH SLIOIARY EXANIHAT IOH AREA CATGY EXAH A E I 0 E REHARKS NUHBER IDENT IF I CATION ITEN NO HETHOO PROCEDURE T C G H R ~~CALIBRATION BLOCK~~

YSTEN NO. 71 5613-P-796-S SH 1 OF 2 REF. DMG. NO. 3-874 317200 781018- H-321-03 I A C-C HT NDE 2.2.9 C X . ~ . 10/21/92 . NT COHPLETE INTEGRAL ATTACHHEHT C3.20 CTNT, 33'11" 40N/At 1 SYSTEN NO. 71 5613 P 796.S SH. 2 OF 2 REF. DWG. NO. 3-874 318300 781018-H-321-01 IA C-C HT NDE 2.2.9 C X - - . 10/21/92 - NT CONPLETE INTEGRAL ATTACHHENT C3.20 CTHT, 26'0" N/A~~

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 PAGE: 33 REVISIONI 1 INSERVICE INSPECT ION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 2 ALL STATUS COMPONENTS F DNATER SYSTEH LOOP N I 0 ZONE NUHBER: 109 ASME S ONGT SEC. XI RSEH SUHHARY EXAHIMAT ION AREA CATGY EXAM A E I 0 E REHARKS NUHBER IDEMt IF ICATION ITEH NO HETHOD PROCEDURE T C G H R ++CALIBRATION BLOCK ~

SYST H NO. 74 5613-P.817-S SM. 4 OF 6 REF. DlC NO 3 866 327340 3.109-A1 F-8 VT-3 NDE 4.3.28 C X .. - 10/13/92 . VT COHPLETE ANCHOR F2. 10 CTHT ~ 51 '10" ftN/Alt 327380 3.109-A1 IA C-C Ht NDE 2.2.3 C X - . - 10/12/92 - HT COMPLETE INTEGRAL ATTACMHENT C3.20 CTHT ~ 51 '104

  • AN/A*4 SYSTEH NO. 74 5613-P-651-S SN. 1 OF 1 REF. DUG. NO. 3 B66 330500 AUGHENTED EXAHINATIOM UT NDE 5.16.1 C - X X X 10/19/92 UT COMPLETE, ROOT AND ID FROM NOZZLE RAMP TO 1 DIAMETER -" INST GEOHETRY AND ACCEPTABLE SLAG ON ELBOM CTHT

~*UT.20, UT-29**

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 PAGE: 34 REVISION: 1 INSERVICE INSPECT IOH

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 2 ALL S'TATUS COMPONENTS H FEEDUAT R YSTEH OOP N I ZONE NUMBER: 110 ASNE S ONG SEC. XI T RSE SUSRY EXAMINATION AREA CATGY EXAM A E IO E REMARKS NUMBER IDENT IF I CAT IOH I TEH HO METHOD PROCEDURE T CGH R "tCALIBRA'IION BLOCKtt SYSTEM MO. 74 5613 P-817-S SH. 5 OF 6 REF. DllG. MO. 3 B67 332140 3.110.A1 F-8 VT-3 NDE 4.3.29 C X - .. 10/13/92 VT COMPLETE ANCHOR F2. 10 CTHT, 52'4" ttUT 20tt 332180 3-110.A1 IA C-C HT NDE 2.2-4 C X - ~

10/12/92 - HT COMPLETE INTEGRAL ATTACHHEHT C3.20 CTHT, 52'4" ttN/Att t

SYSTEM NO. 74 5613-P-652-S SH. 1 OF 1 REF. DWG. HO. 3.B67 333800 AUGMENTED EXAHIHAT IOH UT NDE 5.16 2 C - - X 10/20/92 - UT COMPLETE, ROOT, INSIDE FRCH NOZZLE RAHP TO 1 DIAMETER --- INST SURFACE, AND BACKING RING GEOMETRY OH ELBOM CTHT ttUT ~ 20, UT-29tt

DATE: 03/08/93 TURKE'Y POINT NUCLEAR PLANT UHIT 3 PAGE: 35 VISION: 1 INSERVICE INSPEC'IION SUHHARY SECOND INtERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 2 ALL STATUS COHPONEHTS N FEEDMATER SYS'IEH LOOP C N I 0 ZONE NUHBER: 111 ASHE S ONGT SEC. XI T RSEH SUHHARY EXAHIHAT ION AREA CATGY EXAH A E I 0 E REMARKS NUHBER IDENT IF I CATION ITEH NO HETNOO PROCEDURE T C G H R >>>>CALIBRATION BLOCK>>>>

SYSTEH NO. 74 5613 P 817 S SH. 3 OF 6 REF. DMG. NO. 3.B68 334350 14"-FMC-2306-5A C F VISUAL DURING NDE 5.18 A X 9/29/92 EROSION/CORROS I OH EXAHIHAT ION PIPE TO ELBOM C5.21 CNR 92-3-022 REVEALED A PIT NEXT TO MELO, MELD NCR N.92.0241 REPAIRED PMO MO92052428

>>>>UT-20>>>>

SYSTEH NO. 74 5613-P-817-S SN. 6 OF 6 REF. OMG. NO. 3-868 335140 3.111-A1 F 8 VT-3 NDE 4.3.30 C X - - . 10/13/92 - VT COHPLETE ANCHOR F2.10 CTHT, 50'104 N/A >>

335180 3-111-A1 I A C.C Ht NDE 2.2.5 C X - .. 10/12/92 - Ht COHPLETE IHTEGRAL ATtACHHENT C3.20 CTHT, 50'10"

>>>>N/A*>>

SYSTEH NO. 74 5613-P.178-S SH. 1 OF 1 REF. DMG. NO. 3.B68 338200 AUGHEHTED EXAHINATIOH UT NDE 5.16.3 - X - 10/16/92 ~

UT COHPLETE, ROOT AND INSIDE FROH NOZZLE RAHP TO 1 DIAHETER INST SURFACE GEOHETRY ON ELBOII CTHT "UT~ 20( UT-29*>>

DATE: 03/08/93 TURKEY POIHT NUCLEAR PLANT UHII 3 PAGE: 36 VI S ION: 1 INSERVICE INSPECTION SUHNARY SECOHD INTERVALe THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 2 ALL STATUS CONPOHEHTS DUA HEAT EXCHANGER N I 0 ZOHE HUHBER: 115 ASNE S ONGT SEC. XI T RSEH SUHNARY EXAMINATION AREA CATGY EXAN A E I 0 E REMARKS NUNBER IDENTIFICATION ITEH NO NE'fKOO PROCEDURE T C G N R ~~CALIBRATION BLOCKi~

REF. OUG. NO. 3 V14A 341300 C-A UT 45 HDE 5 4-3 C . X 11/2/92 UT CONPLETE, ROOT AND DIVIDER 3 RHE-A2 ~

SHELL TO TUBESHEET , C1.30 UT 60 HDE 5.4.3 X PLATE GEOHETRY

++PL SS 1 018 55++

342300 3-RHE-SPA.1 C-C PT NDE 3.3-14 C X ~ - - 11/2/92 - PT CONPLETE INTEGRALLY MELDED SUPPORT C3.10 ooN/A10 342500 3-RHE.SPA-2 C-C NDE 3.3.15 C - - - X 11/2/92 - Pf COHPLETE, POSSIBLE SURFACE INTEGRALLY MELDED SUPPORT PI'3.10 CNR 92.3.051 CHECKIHG DUE TO GRIHDIHG, INDICATION NCR H.92.0284 RENOVED BY ADDITIONAL SURFACE CMO 500782 PREPARATION PT W.92.0669 X - . ~ ~*H/A*i

TURKEY POINT NUCLEAR PLANT UNIT 3 PAGE: 3T DATE: 03/08/93 VIS IOH: 1 INSERVICE INSPECTIOH

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 2 ALL STATUS COMPONENTS SS TDONN HEAT EXCHANGER N I 0 ZOHE NUMBER: 117 ASME S OHGT SEC. XI T RSEH

SUMMARY

EXAMIHAT ION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENT IF I CAT IOH ITEM NO METHOD PROCEDURE C G M R ~iCALIBRATION BLOCK~*

REF. DUG. NO. 3 V15 344450 3.LOHX.LS UT-45 NDE 5.4-1 C X .. 10/12/92 - UT COMPLETE, EXAM NOT UT-60 NDE 5.4 1 X . REDUIRED BUT WAS PERFORMED AS PART OF LOHGITUDIHAL SEAM IIELD CTMT 3.LDHX-2 aaUT 4)at 344500 3.LDHX.2 C.A UT.45 NDE 5.4-1 C X 10/12/92 UT COMPLETE, GEOMETRY FROM C1.30 UT.60 NDE 5.4-1 X - INTERNALLY MELO DIVIDER PLATE AND ROOT SHELL TO FLAHGE GEOMETRY CTMT 10UT 414k

DATE: 03/08/93 TURKEY POIMT kUCLEAR PLAN'I UNIT 3 PAGE: 38 VISION 'I INSERVICE INSPECTION SUHHARZ SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 3 ALL STATUS COHPONENTS PON MT COO ING llATER SYSTEH INS DE CONTAINHENT M I 0 20ME NUHBER: 118 ASNE S OMGT SEC. XI T RSEN SUHHARY EXAHIMATION AREA CATGY EXAH A E I 0 E REHARKS NUMBER IDENTIFICATION ITEH NO METHOD PROCEDURE C G H R ~~CALIBRATION BLOCK~~

SYSTEH kO. 30 5613.P 628 S SN. 1 OF 5 REF. DUG. NO. 3.C01 344900 PS-160 F-B VT-3 NDE 4.3-7 C X - - - 10/6/92 - Vt COMPLETE PIPE SUPPORT F2.10 CTHT, 17'0" tkk/Ao~

344910 PS-160 IA 0-A VT-3 NDE 4.3-7 C X - - - 10/6/92 VT COMPLETE INTEGRAL ATTACNHENTS 01.20 CTHT, 17'0" teak/A*t 344950 3-118-A1 F 8 VT-3 NDE 4.3.8 C X . 10/6/92 . VT CCHPLETE ANCHOR F2.10 CTHTi 21'04

    • N/A~~

60 3-118 A1 IA D A VT-3 NOE 4.3-8 C X - - - 10/6/92 - Vr COMPLETE INTEGRAL ATTACHMENT 01.20 CTHT, 21'0" t tk/A1f

TURKEY POINI NUCLEAR PLANT UNIT 3 PAGE: 39 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 3 ALL STATUS COHPONENTS OHPONEMT COOLING MATER SYSTEH NSIOE CONTAINMENT N I 0 ZONE NUHBER: 119 ASHE S ONGT SEC. XI RSEH SUWRY EXAHIMATION AREA CATGY EXAM A E I 0 E REHARKS NUMBER IDENTIFICATION ITEH NO HETNOO PROCEDURE T C G H R ~~CALIBRATION BLOCK~~

SYSTEH NO. 30 5613-P-627-S SN. 2 OF 3 REF. DUG. NO. 3-C02 345100 3-119-A1 F.B VT-3 NDE 4.3-12 C X - ~

10/6/92 . VT COMPLETE ANCHOR F2.10 CTHE 21'0" 345150 3.119.A1 IA D-A VT-3 NDE 4.3.12 C X - 10/6/92 . VT COHPLETE INTEGRAL ATTACNHENT 01.20 C'THT, 21'Ou 345200 3-ACH.102 F.B VT-3 NDE 4.3.9 C . - . X 10/6/92 VT COMPLETE, DRAMING PIPE SUPPORT F2.10 CNR 92-3.019 OISCREPENCY, COD SIZE ANCHOR BOLT AND t

CTHT, 17'0" NCR N 92 0249 NUT, ACCEPTED AS IS BY ENGINEERING EVALUATION NCR N.92.0249

  • "N/A**

0 3.ACH-102 IA 0-A VT-3 NDE 4.3.9 C X - . - 10/6/92 - VT COHPLETE IHTEGRAL ATTACHMENT D1.20 CTHE 17'0"

~ eN/Alt 345300 3-ACH-103- F.B VT-3 NDE 4.3 10 C X . - . 10/6/92 . VT COHPLETE PIPE SUPPORT F2. 10 CTHE 17'0"

~*N/A**

345310 3-ACH-103 I A D.A VT 3 NDE 4.3-10 C X - - - 10/6/92 VT COMPLETE INTEGRAL ATTACHHEN'I D1.20 CTHT, 17'0"

~~N/A~~

345320 3-ACH-104 F-8 VT-3 NDE 4.3-11 C X ~ ~

10/6/92 . Vl'OMPLETE PIPE SUPPORT F2.10 CTHT, 17'0"

~*N/A*>>

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 PAGE: 40 tSIOH 1 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, 'THtRD PERIOD, SECOND OU'IAGE (92RF)

CLASS 3 ALL STATUS COMPONENTS POMENT NG llATER SYST H MS D OMTAINHENT H I 0 20NE NUMBER: 119 ASHE S ONGT SEC. Xt T RSEH

SUMMARY

EXAHINA'TION AREA CAT GY EXAH A E I 0 E REMARKS NUMBER IDENT IF I CAT IOM ITEH NO METHOD PROCEDURE T C G H R ~~CALIBRATION BLOCK ~

SYSTEH MO. 30 5613 P 627-S SH 2 OF 3 REF. DUG. NO. 3 C02 345330 3.ACH-104 IA 0-A VT-3 MDE 4.3-11 C ,X - . - 10/6/92 - VT COMPLETE INTEGRAL ATTACHMENT 01.20 CTHI', 17'0" 40N/jPO

DATE: 03/08/93 TURKEY POINT HUCLEAR PLANT UNIT 3 VISION: 1 IHSERVICE INSPECTIOH SUHHARY SECOND INTERVAL, THIRD PERIOD, SECOHD OUI'AGE (92RF)

CLASS 3 Al.l. STATUS COMPONENTS ONPONEHT COOLING MAYER FRON NORNAL CONT. COOLER 0 H I 0 ZONE NUHBER: 123 ASHE S OHGZ SEC. XI RSEH '

SUNNARY EXAlllHAT ION AREA CAZGY EXAN A E I 0 E REHARKS NUNBER IDENT IF I CAT I OH ITEN NO NETMOO PROCEDURE C G K R ~ CALIBRAZIOH BLOCK~~

SYSZEH NO. 30 5613 P-630 S SH. 1 OF 3 REF. DUG. HO. 3-C06 347600 3-CCH-10 F-8 VZ-3 HDE 4.3.13 10/6/92 VZ CONPLEZE BOX RESZRAINT F2 '0 CTNT, 34'84 N/A

  • 347610 3.CCN.10 IA D.B VT 3 HDE 4.3 13 C X - - - 10/6/92 - VT COHPLETE IN'IEGRAL ATTACHNEHZS D2.20 CTHE 34'8"

~~H/A*~

347700 3-123-Al F.B VT-3 NDE 4.3-14 C X ~ . - 10/6/92 . VZ CONPLEZE ANCHOR F2.10 CTHE 31'0" aaN/Aae 0 3-123-A1 IA D-8 VT-3 NDE 4.3-14 C X - .. 10/6/92 VT COHPLEZE INTEGRAL ATTACHHENT 02.20 CTHZ, 31'0" 1tN/Atf

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 VISION: 1 IHSERVICE INSPECTION SUHHARY SECOND INTERVAL, THIRD PERIOD, SECOND OU'IAGE (92RF)

CLASS 3 ALL STATUS COHPONEHTS POH HT COOL NG MATER TO EHERGEHCY CONT. COOLER B H I 0 ZONE NUHBER: 128 ASHE S ONGT SEC. XI T RSEH SUHHARY EXAHIHATION AREA CATGY EXAH A E I 0 E REHARKS NUHBER IDEHTIF I CAT IOH ITEH NO HETHOD PROCEDURE T C G N R CALIBRATIOH BLOCK**

SYSTEH HO 30 5613.P-589-S SH 1 OF 1 REF DMG. NO. 3.C11 349700 280A-2 F.B VT-3 NDE 4.3.15 C X . - - 10/6/92 - VT COHPLETE SLIDIHG STANCHION F2.10 CTHT, 59'8"

~ tH/A*~

349710 280A-2 IA D-B VT-3 NDE 4.3-15 C X ~ - ~

10/6/92 - VT COMPLETE INTEGRAL ATTACNHEHT 02.20 CTHT, 59'8"

  • tN/A44 350700 3.128-A1 F.B VT.3 NDE 4.3-16 C X - - - 10/6/92 - VT COHPLETE ANCHOR F2.10 CTHE 31'0"

)I ~+N/A**

0 3-128-A1 IA D.B VT-3 NDE 4.3-16 C X ~ . - 10/6/92 - VT COHPLETE INTEGRAL ATTACHHEHT 02.20 CTHE 31'0" toN/Alt

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANl UHIT 3 VISION: 1 INSERVICE INSPECT ION SUNNARY SECOND IHTERVAL, THIRD PERIOD, SECOHD OUTAGE (92RF)

CLASS 3 ALL STATUS CONPOHEHTS POHEHT COOLING llATER TO NORNA CONT. COOLERS N I 0 ZONE HUHBER: 129 ASHE S ONGT SEC. XI T RSEH SUNHARY EXAHINATIOH AREA CATGY EXAN A E I 0 E REHARKS HUHBER IDEN'TIFICATIOH ITEN NO NE'THDD PROCEDURE T C G N R *>>CALIBRATIOH BLOCK>>>>

YSTEN NO. 30 5613-P.631-S SH. 2 OF 3 REF. DMG. NO. 3 '12 350900 3 CCH-9 F 8 VT-3 HDE 4.3-23 C X ~ . 10/6/92 - VT COMPLETE BOX RESTRAINT F2. 10 CTHT, 34'8"

>>>>H/A>>>>

350910 3.CCH-9 IA D.B VT-3 NDE 4.3.23 C X 10/6/92 VT CONPLETE INTEGRAL ATTACHHENTS D2 ~ 20 CTHT, 34'8

    • N/A>>>>

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANt UNIT 3 PAGE: 44 EVI SION: 1 IHSERVICE INSPECTION SUNHARY SECOND INTERVAL, THIRD PERIOD, SECOHD OUTAGE <92RF)

CLASS 3 ALL STATUS COKPONENTS P NENT COOLING WATER tO HORHAL CONT. COOLERS A&B N I 0 ZONE NUHBER: 130 ASKE S OHGT SEC. XI T RSEH SUHHARY EXAIIIHAT ION AREA CATGY EXAH A E I 0 E REHARKS NUNBER IDENTIFICATION ITEN NO NETHCO PROCEDURE C G H R ~~CALIBRATION BLOCK~~

STSTEH NO. 30 5613.P.631.S SH. 1 OF 3 REF. DWG. NO. 3-C13 352100 281-3 F 8 VT-3, NDE 4.3.17 C X - 10/6/92 - VT COHPLETE SLIDING STANCHION F2. 10 CTHT, 59'9" skH/Akk 352110 281-3 I A 0 8 VT 3 HDE 4.3-17 C X - - 10/6/92 VT COHPLETE INTEGRAL ATtACHHENT 02.20 CTHT, 59'9"

~ H/All

DATE: 03/08/93 TURKEY POlkT NUCLEAR PLANT Ukll 3 PAGE: 45 VISION 1 INSERVICE INSPECTIOH SUNHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 3 ALL STATUS COHPOHEHTS HEHT COOLING MATER TO EHERGENCY COHT ~ COOLER C N I 0 ZOHE NUHBER: 132 ASKE S OHGT SEC. XI T RS EH SUHHARY EXAHIHATIOH AREA CATGY EXAN A E I 0 E REHARKS NUHBER IDENTIFICATION ITEK HO HETNOD PROCEDURE I C G H R ~~CALIBRATION BLOCK~~

YSTEH NO. 30 5613-P 591-S SH 1 OF 1 REF. DMG. NO. 3-C15 352400 3.132.A1 F-8 VT 3 HDE 4.3 19 C X . . . 10/6/92 - VT COHPLETE PEHETRATIOH AHCHOR F2.10 CTHT, 31'04 H/A 352450 3-132-A1 IA D-8 VT 3 NDE 4.3-19 C X - - - 10/6/92 - VT COHPLETE INTEGRAL ATTACHHEkT D2.20 CTHT, 31'0" iok/AN*

352500 3-CCH-12 F B VT 3 NDE 4.3 18 C - X 10/6/92 - VT COHPI.ETE, DRAMING PIPE SUPPORT F2.10 CNR 92.3-017 OISCREPENCY, EX'IRA HUTS AND MASHERS ON CTHE 34'74 PMO 92046735 SUPPORT, ACCEPTED AS-IS ~ MILL BE CORRECTED MITH PLANT MORK ORDER h'I A 0

352510 3-CCH-12 IA INTEGRAL ATTACHHEHT D.B 02.20 VT 3 HDE 4.3 18 C X ~

FUIURE DATE

  • ek/A*a 10/6/92 - VT COMPLETE CTHE 34'7"

~~N/A*"

TURKET POINT NUCLEAR PLANT UNIT 3 PAGE: 46 DATE: 03/08/93 I S IOM: 1 INSERVICE INSPECIIOH SUHHART SECOHD INTERVAL, THIRD PERIOD, SECOHD OUtAGE (92RF)

CLASS 3 ALL StATUS COHPOMENTS COMPONENT COOLING MATER T EHERG H T CONT. COOLER N I 0 ZONE NUHBFR: 133 ASHE S ONGT SEC. XI RSEH SUHHARY EXAHINATIOH AREA CATGT EXAM A E I 0 E REHARKS MUHBER IDENTIFICATION ITEN HO HETHCO PROCEDURE T C G H R llCALIBRATIOH BLOCK**

STSTEH NO. 30 5613-P 593-S SH 1 OF 1 REF. DUG. NO .C16 F.B 4.3-20 X - - 10/6/92 ~ VT COMPLETE 352900 3-133.A1 VT 3 NDE C AMCHOR F2.10 CTHT, 31'04 ttN/Att 3.133.A1 I A 0-8 VT-3 NDE 4.3 20 C X - - - 10/6/92 . VT COHPLETE 352950 INTEGRAL ATTACHMENT 02.20 CTHT, 31'0" tlN/Att 281A-A F-8 VT.3 NDE 4.3.40 C X - - - 10/26/92 - VT COHPLETE 353800 ANCHOR F2.10 CTHT, 57'10"

'llH/Att 10 281A-A IA 0-8 VT.3 NDE 4.3.40 C X - - . 10/26/92 . VT COMPLETE INTEGRAL ATTACHHEHT D2.20 CTHT ~ 57'01 11N/All F~8 VT 3 NDE 4.3-41 C X . - - 10/26/92 - VT COMPLETE 353900 SR-60 PIPE SUPPORT F2.10 CTHTt 61'74 1 tH/All 0.8 VT-3 HDE 4.3 41 C X - - - 10/26/92 VT COMPLETE 353910 SR-60 IA INTEGRAL ATTACHHEHT 02.20 CTHT ~ 61'7" 11H/Al*

DATE:~ 03/08/93 TURKEY POINT NUCLEAR PLANT UMI T 3 PAGE: 47 I SION:T 1 IHSERVICE INSPECTION SUHHARY SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 3 ALL S'TATUS COMPONENTS COH H NT COOLING WATER EHERGEMCY CONT.C LER A M I 0 ZONE NUHBER: 134 ASHE S ONGT SEC. XI T RSEH SQOIARY EXAHINAT ION AREA CATGY EXAH A E I 0 E REHARKS PROCEDURE I' G H R ~~CALIBRATION BLOCK~~

NUHBER IDENT IF I CAT IOM ITEM NO HETHOD SYSTEH MO. 30 5613.P.592-S SH 1 OF 1 REF. DWG. MO. 3.C17 354000 3.134-A1 F-B VT-3 NDE 4.3-22 C X - - - 10/6/92 - VT COHPLETE ANCHOR F2.10 CTHT ~ 31'04

~~N/A~~

354050 3-134.A1 I A D.B VT.3 NDE 4.3.22 C X ~ ~ - 10/6/92 - VT COHPLETE INTEGRAL ATTACHHENT 02.20 CTHT, 31'04 1tN/Alt 354100 3.CCH-11 F-B VT.3 HDE 4.3-21 C - .. X 10/6/92 ~ VT COHPLETE, DRAWING PIPE SUPPORT F2.10 CNR 92.3.018 DISCREPEHCY, INCORRECT NUHBER OF HUTS ON CTHT~ 34<74 PWO 92046732 SUPPORT, ACCEPTED ASSIS, WILL BE CORRECTEO WITH PLANT WORK ORDER AT A FUTURE DATE

~ AM/Ak*

354110 3-CCH.11 IA O.B VT-3 NDE 4.3-21 C X ~ ~ - 10/6/92 - VI'OHPLETE INTEGRAL ATTACHHENT 02.20 CTHT, 34'74

~~N/A~~

DATE:~ 03/08/93 TURKEY POIHT NUCLEAR PLANT UNIT 3 PAGE: 48 I SION:~ 1 IHSERVICE INSPECTIOH SUHNARY INTERVALED SECOND tHIRD PERIODS SECOND OUTAGE (92RF)

CLASS 3 ALL STATUS CCFIPONEHTS COM EHT COOLING WATER SYSTEN OU'ISIDE CONTAIMHENT N I 0 2OHE HUHBER: 136 ASHE S ONGT SEC. XI T RSEH SUWRY EXAHINATIOH AREA CATGY EXAH A E I 0 E REMARKS IDENT IF I CATION NUHBER ITEN NO HETHOO PROCEDURE T C G H R ~~CALIBRATION BLOCK~~

SYSTEN NO, 30 5613.P-618 S SH. 1 OF 2 REF. DWG. NO. 3 C19 356000 3-ACH-19 F-B VT-3 NDE 4.3-38 C X .. 10/26/92 - Vt COHPLETE ANCHOR F2.10 21'04

~~N/A*~

3.ACH-19 IA D-A VT-3 NDE 4.3-38 C X - - 10/26/92 - VT COHPLETE 356010 INTEGRAL ATTACHNENI'1'0" D1.20 kfH/A1*

DATE: 03/08/93 TURKE'Y POINT NUCLEAR PLANT UNIT 3 REVISION: 1 INSERVICE INSPECTION SUMMAR'Y SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 3 ALL STATUS COMPONENTS POHEHT L NG HAT R SYSTEM OUTSIDE CONTAINMENT H I 0 ZOHE NUMBER: 137 ASME S OHG7 SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE C G M R CALIBRATIOH BLOCK SYSTEM NO. 30 5613-P-603-S SH. 1 OF 1 REF. DlJG. NO. 3-C20 356100 SR-298 F-C Vr-3 NDE 4.3-39 C X - - - 10/26/92 - VT COMPLETE ANCHOR F3.10 8iPu ilN/Aft SR.298 I A D-B VT-3 HDE 4.3.39 C X . . . 10/26/92 - VT COMPLETE 356150 INTEGRAL ATTACHMENTS D2.20 8>P<<

ttN/Aoo

k lt DATE: 03/08/93 TURKEY POINT NUCLEAR PLANt UNIT 3 PAGE: 50 REVISION: 1 INSERVICE INSPECTION

SUMMARY

SECOND INlERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 3 ALL STATUS COMPONENTS COHPONEHT COOLING MATER SYSTEH OUTSIDE CONTAINMENT H I 0 ZONE NUMBER: 139 ASHE S OHGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAH A E I 0 E REMARKS NUMBER IOEHTIFICATIOH ITEH MO HETHOO PROCEDURE T C G H R ~~CALIBRATIOM BLOCK~~

SYSTEM NO. 30 5610 P 603-S SH. 1 OF 1 REF. DMG. NO. 3.C22 356740 SR.297 F.B 'T.3 NDE 4.3.36 C - . - X 10/21/92 VT COMPLETE, INCOMPLETE ANCHOR F2.10 CNR 92-3.043 THREAD ENGAGEHENT, ACCEPTED AS-IS BT 8'04 NCR N.92.0269 ENGINEERIHG EVALUATION

~~N/A~~

356780 SR.297 IA 0-e Vt-3 NDE 4.3.36 C X - - - 10/21/92 - VI'OHPLETE INTEGRAL ATTACKHEN'TS 02.20 81 Oil O~N/A**

DATE: 03/08/93 TURKEY POINT HUCLEAR PLANT UNIT 3 PAGE: 51 REVISION: 1 INSERVICE INSPECTION

SUMMARY

SECOHD INTERVAL, THIRD PERIOD, SECOND OU'IAGE (92RF)

CLASS 3 ALL STATUS COMPONENTS PONENT COOLING WATER TO SEAL 'WATER S NON.REG.HX N I 0 ZONE NUMBER: 141 ASHE S OHGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 30 5613-P-623-S SH. 1 OF 2 REF. DWG. NO. 3.C24 357800 3-ACH-143 F-C VT-3 NDE 4.3 33 A X - - 10/19/92 - Vl RE-EXAH COMPLETE ROO HANGER F3.10 36 I 6u

  • iN/A**

l" DATE: 03/08/93 TURKEY POINT HUCLEAR PLANT UHIT 3 PAGE: 52 REVISION: 1 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 3 ALL STATUS COMPOHEHTS PONENT COOLING WATER SYSTEM OUTSIDE COHTAINMENT H I 0 ZONE NUMBER: 145 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM HO METHOD PROCEDURE T C G M R **CALIBRATIONBLOCK**

SYSTEM NO. 30 5613-P-604-S SH. 6 OF 6 REF. OWG. HO. 3-C28 360700 3.ARH ~ 124 F-8 VT-3 NDE 4.3 6 C - - - X 10/2/92 - VT COMPLETE, CHIPPED CONCRETE PIPE SUPPORT F2.10 CHR 92-3.010 AT BASE OF SUPPORT, ACCEPTEO AS IS, WILL 11 '6" PWO 92046125 BE CORRECTEO WITH PLANT WORK ORDER AT A FUTURE DATE

~*k/A*~

360710 3-ARH-124 I A D.B VT-3 HOE 4.3-6 C X 10/1/92 VT COMPLETE@ BROKEN WELOSI INTEGRAL ATTACHMENT 02.20 CNR 92.3-011 11/16/92 - VT RE-EXAMINATION BY ac 11'64 HCR N.92-0205 SHOWED WELOS WERE IHTACT AHD IHDICATIOHS WERE COLD LAP AND SLAG THAT HAD BEEN PAINTED, ACCEPTEO AS IS BY ENGINEERING EVALUATION

    • N/A**

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 PAGE: 53 REVISION: 1 INSERVICE INSPECTIOH

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 3 ALL STATUS COMPONENTS PONEN'f COOLING llATER SYSTEM OUTSIDE CON'fAINMENT N I 0 ZOHE NUMBER: 150 ASME S OHGT SEC ~ Xl T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUHBER IDEN'flFICATIOH ITEM HO METHOD PROCEDURE T C G M R ~~CALIBRATION BLOCK*~

SYSTEM NO. 30 5613-P-613-S SH, 3 OF 3 REF. OWG. NO. 3-C33 363675 3-CCH-27 F-C VT-3 NDE 4.3-4 C - - - X 10/1/92 - VT COMPLETE( PAINTED SPHERICAL RIGID STRUT ~

F3.10 CHR 92-3.009 BEARINGS, ACCEPTED AS-IS, HILL BE 19'34 PWO 92046127 CORRECTED MITH PLAHI'ORK ORDER AT A FUTURE DATE

~~N/A~*

363680 3-CCH-27 IA D.B VT.3 HDE 4.3.4 C X... 10/I/92 . VI'OMPLETE INTEGRAL ATTACHMENT D2.20 19'3"

    • N/Ai*

DATE: 03/08/93 TURKEY POIN'I NUCLEAR PLANT'NIT 3 PAGE: 54 REVISION: 1 INSERVICE INSPECTION

SUMMARY

SECOND IN'IERVAL, THIRD PERIOD, SECOND OU'IAGE (92RF)

CLASS 3 ALL STATUS COMPONENTS PONENT COOLING HATER FROM RNR HEAT EXCHANGER A N I 0 ZONE NUMBER: 153 ASHE S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REHARKS NUMBER IDENTIFICATION ITEM NO HETHOD PROCEDURE T C G H R +*CALIBRATION BLOCK**

SYSTEH NO. 30 5613-P-612-S SH. 1 OF 2 REF. DNG. NO. 3-C37 365600 3-SR-345 F-C V'T-3,4 NDE 4.3-25 C - - - X 10/12/92 - VT COMPLETE, BENT ROO, SMALL SPRING HANGER F3.50 CNR 92.3-022 COTTER PIN, 'SPRING SET'TING OUT OF 22'04 NCR N-92-0242 TOLERANCE, INCOMPLETE THREAD ENGAGEMENT, PWO 92052376 COTTER PIN REPLACED AND SPRING CAH RESET, OTHER ITEMS ACCEPTED AS-IS BY ENGINEERING EVALUATION

    • N/A*"

365650 3-SR-345 IA O-B VT-3 NDE 4.3-25 C X - - - 10/12/92 . VT COMPLETE INTEGRAL ATTACHMENT 02.20 22'0" kkN/A~0 365660 3-SR-347 F-C VT-3 NDE 4.3-3 C - - . X 10/1/92 - DRANING DISCREPENCYI STRESS PIPE SUPPORT F3 ~ 10 CNR 92-3.014 CALC PTN-3FSC.91-175 ACCEPTS AS-IS, DRAWING HILL BE UPDATED

  • ~N/A~~

365670 3.SR-347 IA D.B VT-3 NDE 4.3 3 C X . . - 10/1/92 - VT COMPLETE IHTEGRAL ATTACHMENTS 02.20 19 I 9II itN/Atk SYSTEM NO. 30 5613-P-612-S SH. 2 OF 2 REF, DWG. NO. 3-C37 366175 SR-138 F.C VT-3 NDE 4.3-5 C X - - - 10/1/92 - VT COMPLETE BOX RESTRAINT F3.10 12'04 t*N/Ae*

DATE: 03/08/93 TURKEY POINT NUCLEAR PLANT UNIT 3 REVISION - 1 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 3 ALL STATUS COMPONENTS XILIARY FEEDMATER PUMP SUCTION FROM COND.STG.TK.

N I 0 20NE NUMBER: 164 ASME S OHGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM HO METHOD PROCEDURE T C G M R *~CALIBRATION BLOCK*"

SYSTEM NO. 74 5610-P-818-S SH. 1 OF 3 REF. DWG. NO. 3-C48 376800 80117-H-340.06 F AC VT-3 HDE 4.3 ' C X - - - 10/1/92 - VT COMPLETE SLIDING STANCHION F3.10 20'9" 4*N/Ats 376850 80117 H 340.06 IA D.B VT-3 HDE 4.3.1 C X... 10/1/92 - VT COMPLETE INTEGRAL ATTACHMEHT D2.20 20 l 9ll

    • N/A*t

DATE: ,03/08/93 TURKEY POINI'UCLEAR PLANT UNIT 3 PAGE: 56 REVISION: 1 INSERVICE INSPECTION

SUMMARY

SECOND INTERVAL, TNIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 3 ALL STATUS COMPONENTS TAKE COOLING llATER TO CCN HEAT EXCHAHGERS N I 0 ZONE NUMBER: 168 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDENTIFICATION ITEM NO METHOD PROCEDURE T C G M R >>>>CALIBRATION BLOCK>>*

SYSTEM NO. 19 5613-P-633-S SH. 2 OF 2 REF. DUG. NO. 3-C54 378200 STRAIHER A F-B VT.3 NDE 4.3-2 C X - . . 10/1/92 . VT COMPLETE ANCHORS F2.10 22'12"

>>*N/A>>>>

378205 STRAINER A IA D A VT-3 NDE 4.3.2 C X - - - 10/1/92 - VT COMPLETE INTEGRAL ATTACHHENTS 01 ~ 20 22'12"

>>>>N/A>>>>

g ~C,I DATE: 03/08/93 TURKEY POIH'I NUCLEAR PLANT UNIT 3 PAGE: 57 REVISION: 1 IHSERVICE INSPECTION

SUMMARY

SECOHD INTERVAL, THIRD PERIOD, SECOND OUTAGE (92RF)

CLASS 3 ALL STATUS COMPONENTS LIARY FEED'IJATER SYSTEM PUMP DISCHARGE N I 0 ZONE NUMBER: 171 ASME S ONGT SEC. XI T RSEH

SUMMARY

EXAMINATION AREA CATGY EXAM A E I 0 E REMARKS NUMBER IDEHTIFICATION ITEM NO METHOD PROCEDURE T C G M R *"CALIBRATION BLOCK~~

SYSTEM NO. 74 5610 P.884-S SH. 2 OF 5 REF. DUG. NO. 3-C57 381600 80117. H-320-20 F C Vt-3 NDE 4.3.26 A X - - 10/9/92 - VT COMPLETE( RE EXAMINED TO DUAL RIGID STRUT F3.10 CLOSE OUT PLANT WORK ORDER FROM PREVIOUS 29'64 OUTAGE

%1N/A4*

Turkey Point Unit 3 1992 Refueling Outage Summary of Visual VT-2 Examinations and Third Period Pressure Testing

e Abstract This Report details the hydrostatic testing of selected class 2, and 3 piping and components of the Florida Power and Light Company Turkey Point Unit 3 which were performed during the 1992 refueling outage between August 24, 1992 and December 3, 1992.

Piping and components were selected and tested in accordance with Section XI of the American Society of Mechanical Engineers (ASME)

Boiler and Pressure Vessel code " Rules for Inservice Inspection of Nuclear Power Plant Components", 1980 Edition with addenda through Winter 1981, and ASME Code Case N-498, "Alternative Rules for 10 Year Hydrostatic Pressure Testing for Class 1 and 2 Systems".

Section XI, Division 1 (Approval date May 13, 1991).

Procedures The following FPL procedures and documents have been implemented to provide instructional guidance for the performance of the required ASME XI hydrostatic testing, and subsequent inspections.

AP 0190.90- ASME Section XI pressure tests for quality groups A, B, and Systems/Components.

t C

OP 1506.7 Steam Generator Hydrostatic Pressure Test.

NDE 4.2 Visual Examination VT-2 Conducted during System Pressure Tests.

0-ADM-217 Conduct of Infrequently Performed Tests or Evolutions.

WCAP-13155 Technical Basis for Determination of Secondary Side Pressure Test Temperatures, Turkey Point Units 3 and 4 Steam Generators.

S stem Summar : Unit 3 The following safety related systems, or sections thereof were hydrostatically tested in accordance with ASME Section XI.

Name of system System number Steam Generators 71 Steam Generator Blowdown 71 Main Steam 72 Feedwater 74 Intake Cooling Water 19 Component Cooling Water 30

A~cron s AP Administrative Procedure ADM Administrative ASME: American Society of Mechanical Engineers CCW Component Cooling Water t

HX Heat Exchanger ZCW Intake Cooling Water NCR Non Conformance Report NDE Non Destructive Examination TPCW: Turbine Plant Cooling Water OP Operating Procedure WCAP: Westinghouse Commercial Atomic Power

Test Packa e Develo ment The specific pressure test boundaries were selected after review of the applicable Plant operating diagram/Code boundary Drawing. The piping systems were first broken down into sub-systems. The sub systems were selected based on Technical Specification operability requirements, acceptable isolation points and availability of test connections and vent valves. These sub-systems were then assigned a test package number, which could be tested in the entirety, or based on availability, could be broken down further into numerous tests within that specific sub-system.

The pressure test package numbers contain six segments of information.

Sample: 03-CCW-30110-H-Ol t t t t t t 1 2 3 4 5 6 Unit number (00) common to Units 3 and 4. (03) Unit 3 specific (04) Unit 4 specific

2. System Abbreviation

~ s. System number [First (2) digits]

Sub-System number [(2) or (3) digits]

5. Type of test (H) Hydrostatic (F) System Functional (I) System Inservice
6. Number of tests performed within the specific Sub System.

Intake Coolin Water S stem 19 03-ICW-1989-H-01 Test date 9/27/92 This test involved the ICW piping associated with "A" ICW header, "A" ICW pump, "A" CCW HX, and "B" TPCW HX. All leakage noted during this test was found at mechanical joints (i.e., packing, seals, bolted connections etc.)

which does not require retesting per ASME Section XI. All leakage was addressed by the following Plant Work Orders:

92046262 92046266 92046268 03-ICW-1990-H-01 Test date 10/20/92 This test involved the ICW piping associated with "B" ICW header,"B" and "C" ICW pumps, "B" and "C" CCW HX, and "A" TPCW HX. One area of through-wall leakage noted on a spool piece at the "B" CCW HX discharge run, had been addressed by NCRg N-92-0138 prior to this test, and was pressure tested following replacement. All other leakage noted during was found at mechanical joints (i.e., packing, seals, bolted this'est connections etc.) which does not require retesting per ASME XI and was addressed by the following Plant Work Orders:

92047147 92047151 92047156 92047153 920032468 92047154 92047155

Com onent Coo1in Water 8 stem 30 03-CCW-3002-H-01 Test date 11/4/92 This test included the CCW piping from the 705A and 705B valves to the chemical pot feeder.

All leakage noted during this test was found at mechanical joints (i.e., packing, seals, bolted connections, etc.) which does not recpxire retesting per ASME Section XI. All leakage was addressed by the following Plant Work Orders: 92047987 92047989 03-CCW-3013-H-01 Test date ll/3/92 This test involved the CCW piping between valves 3-730 and 3-732. All leakage noted during this test was found at mechanical joints (i.e., packing, seals, bolted connections, etc.) which does not require retesting per ASME Section XI. All leakage was addressed by the following Plant Work Orders: 92047982 92047983

OP 1506.7 Steam Generator H drostatic Pressure Test Includes S stems 71 72 and 74 OP 1506.7 Test date 9/24/92 This test was performed in order to satisfy all repair/replacement hydrostatic testing requirements which had been deferred in accordance with ASME Code Case N-416 "Alternative Rules for Hydrostatic Testing of Repair or Replacement of Class 2 Piping"Section XI Division 1 (Approval date 12/05/84).

This test included Steam Generators "A" "B", "C" and associated Main Steam, Feedwater, and Blowdown piping extending to the "B" to D I or the "B" to "SR" class breaks outside containment. All leakage noted during this test was found at mechanical joints (i.e., packing, seals, bolted connections, etc.) which does not require retesting per ASME Section XI. All leakage was addressed by the following Plant Work Orders:

92045782 92045785 92045786 92045788 92045789 92045790 92045792 92045793 92045798 92045816 92045819 92045861 92045064 92045866 92045867 92045871 92045902 92045957 92042272 92045979 92045979 92045981 92045983 92045984 92031230 92031228 92042279 92031229 92045991 92045993 92045996 92045983 92045997 92046000 92031233 92031231 92046001 92046002 92046004 92046005 92046006 92046007 92046008 92046009 92046010 92046011 92046012 92046014 92046015 92046017

)