O~ ~<CIj(
Wp,
~
0 t
0 Iy
~O
++*++
Docket Nos.
50-250 and 50-251 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON. D. C. 20555 Nay 31, 1988 Hr.
M. F.
Conway Senior Vice President - Nuclear Florida Power and Light Company P.O.
Box 14000 Juno Beach, Florida 33408 Dear Nr.
Conway:
SUBJECT:
TURKEY POINT UNITS 3 AND 4 REACTOR VESSEL FRACTURE TOUGHNESS (TAC NOS.
68249 AND 55042)
The purpose of this letter is to transmit our review of two reports submitted by Florida Power and Light Company (FP8 L).
These reports were intended to demonstrate by analysl.s the existence of adequate safety margins in the Turkey Point Units 3 and 4 reactor vessels when the Charpy upper-shelf energy is below the 50 ft-lb requirement in Appendix G of 10 CFR 50.
By letters dated May 3, 1984 and March 25, 1986, FP8L submitted for NRC.'s review a, fracture toughness analysis of the beltline welds for the Turkey Point reactor vessels.
In our Safety Evaluation (enclosed) we have identified the need for additional analysis and data acquisition.
Until this information is provided, we cannot complete our review of the reports.
Me request that within one year of the date of this letter, FP8IL provide a revised analysis incorporating the information requested and a plan for data acquisition.
The analysis should include an estimate of the Charpy upper-shelf energy at both the next refueling outage following the submittal date of the report and at expiration of the Turkey Point Units 3 and 4 licenses.
The Charpy upper-shelf energy estimates for the beltline weld should be based on the plant's anticipated future fuel management plan and extrapolation of the
,surveillance data from the Turkey Point Integrated Surveillance Program using the method recommended in Regulatory Guide 1.99, Rev. 2.
Me also recommend that FP8L contact the ASME Code Section XI Committee (Morking Group on Flaw Evaluation) to determine the status of the Committee's development of recommended safety margins and any impact they would have on Turkey Point if approved for use by the NRC.
88060702if 88053l PDR ADOCK 05000250',
i P
May 31, 1988 Mr.
W. F.
Conway The reporting and/or r ecordkeeping requirements contained in this letter affect fewer than 10 respondents; therefore, ORB clearance is not required under P.L.96-511.
S incere ly,
Enclosure:
As stated Gordon E. Edison, Sr. Project Manager Project Directorate II-2 Division of Reactor Projects-I/II Office of Nuclear Reactor Regulation cc w/enclosure:
See next page D.ISTRIBUTION RRC POR Local PDR PD22 Reading S.
Varga G. Lainas D. Miller G. Edison OGC-WF E. Jordan J. Partlow ACRS (10)
Gray File B. Elliot K. Wickman N. Randall W. Mazelton C.
Y. Cheng
- See previous concurrence
- LA:PDII-2 DMi 1 1er 5/
/88 PM: PDI I-2 GEdison:bg 5/pf,/88 H e w
5/yl/88
tr
,, ~
LI if
I Mr. H. F.
Conway The reporting and/or recordkeeping requirements contained in this letter affect fewer than 10 respondents; therefore, OMB clearance is not required under P.L.96-511.
Sincerely,
Enclosure:
As stated Gordon E. Edison, Sr. Project Manager Project Directorate II-2 Division of Reactor Projects-I/II Office of Nuclear Reactor Regulation cc w/enclosure:
See next page DISTRIBUTION Doc et Fa e
NRC PDR Local PDR PD22 Reading S.
Varga G. Lainas D. Miller G. Edison OGC-1IF E. Jordan J. Partlow ACRS (10)
Gray File B. Elliot K. tlickman N. Randall ll. Hazelton C.
Y. Cheng L:
-2 8'r 5/g~/88 PM: PDI I-2 GEdison:bg 5/gt/88 D: PDI I-2 HBerkow 5/
/88
rr I
~
Nr.
M. F.
Conway Florida Power and Light Company Turkey Point Plant CC:
Harold F. Reis, Esquire Newman and Holtzinger, P.C.
1615 L Street, N.M.
Mashington, DC 20036 Nr. Jack Shreve Office of the Public Counsel Room 4, Holland Building Ta 1 1 ahas see, Florida 32304 John T. Butler, Esquire
- Steel, Hector and Davis 4000 Southeast Financial Center Miami, Florida 33131-2398 Mr. J.
Odom, Vice President Turkey Point Nuclear Plant Florida Power and Light Company P.O.
Box 029100 Miami, Florida 33102 Administrator Department of Environment, Regulation Power Plant Siting Section State of Florida 2600 Blair Stone Road Tallahassee, Florida 32301 Reg iona 1 Admini s tra tor, Reg ion U.S. Nuclear Regulatory Commiss Suite 2900 101 Marietta Street Atlanta, Georgia 30323 Attorney General Department of Legal Affairs The Capitol Tallahassee, Florida 32304 County !tanager of t)etropolitan Dade County f~iami, Florida 33130 Resident Inspector U.S. Nuclear Regulatory Commission Turkey Point Nuclear Generating Station Post Office Box 57-1185 Miami, Florida 33257-1185 Jacob Daniel Nash Office of Radiation Control Department of Health and Rehabilitative Services 1317 Minewood Blvd.
Ta 1 lahassee, Florida 32399-0700 Inter governmental Coordination and Review Office of Planning 8 Budget Executive Office of the Governor The Capitol Building Ta 1 lahassee, Florida 32301 Plant thanager Turkey Point Nuclear Plant Florida Power and Light Company P.O.
Box 029100 Miami, Florida 33102