Text
\\
'a eptember 24, 1986 I
1 Docket Nos.:
50-250 and 50-251 Mr. C. 0.
- Woody, Group Vice President Nuclear Energy Department Florida Power and Light Company Post Office Box 14000 Juno
- Beach, Florida 33408 DISTRIBUTION
- NRC PDR
- Local PDR
- PAD¹2 Rdg
- T. Novak
,"OGC-Bethesda
- E. Jordan
- B. Grimes
- J. Partlow
- Without enclosures
- N. Thompson D. McDonald
- D. Miller
- ACRS (10)
- Gray File
Dear Mr. Woody:
SUBJECT:
ANTICIPATED TRANSIENTS WITHOUT SCRAM - TURKEY POINT UNITS 3 AND 4
Reference:
TAC Numbers 59153 and 59154 The Nuclear Regulatory Commission (NRC) staff has completed its review of the Westinghouse Owners'roup (WOG) Topical Report WCAP-10858 "AMSAC Generic Design Package" submitted in response to 10 CFR 50.62 "Requirements for Re-duction of Risk from Anticipated Transient Without Scram (ATWS) Events for Light-Water-Cooled Nuclear Power Plants."
Guidance for meeting the require-ments of 10 CFR 50.62 was provided in the preamble to that rule and was further provided to all licensees in Generic Letter 85-06 "guality Assurance Guidance for ATWS Equipment That is Not Safety Related."
The results of the staff's review of the generic design for the ATWS mitiga-tion system actuation circuitry (AMSAC) are contained in the attached Safety Evaluation (SE).
The staff has concluded that the generic design is acceptable;
- however, many plant specific details needed in order to ensure conformance with the rule are not addressed by the WOG generic design.
These details needed by the NRC to complete the review are defined in the SE.
We request that you review the SE and provide, within 30 days of receipt of this letter, your schedules for addressing the plant specific design features discussed in Appendix A of the SE, and for implementation following the staff's approval of your plant specific design.
This request for information is covered under OMB clearance number 3150-0011 which expires September 30, 1986.
If you have any questions, please contact me at (301) 492-4777.
Sincerely, 8610020+1g 8g0ggy PDR ADOCK 05000250
~
PD@j I
Enclosure:
As Stated cc:
See next pa A&innlSigned by Daniel G. McDonald, Senior Project Manager PWR Project Directorate ¹2 Division of PWR Licensing-A D
r 9/
86 D¹2 McDonald:hc 9/g'f/86 PD:PAD¹2 LRubenstein 9Pg/86
1
Mr. C. 0.
Woody Florida Power and Light Company I
Turkey Point Plant CC:
Harold F. Reis, Esquire Newman and Holtzinger, P.C.
1615 L Street, N.W.
Washington, DC 20036 Mr. Jack Shreve Office of the Public Counsel Room 4, Holland Building Tallahassee, Florida 32304 Norman A. Coll, Esouire
- Steel, Hector and Davis 4000 Southeast Financial Center Miami, Florida 33131-2398 Mr. C.
M, Wethy, Vice President Turkey Point Nuclear Plant Florida Power and Light Company P.O.
Box 029100 Miami, Florida 33102 Mr. M. R. Stierheim County Manager of Metropolitan Dade County Miami, Florida 33130 Resident Inspector U.S. Nuclear Regulatory Commission Turkey Point Nuclear Generating Station Post Office Box 57-1185 Miami, Florida 33257-1185 Mr. Allan Schubert, Manager Office of Radiation Control Department of Health and Rehabilitative Services 1317 Winewood Blvd.
Tallahassee, Florida 32301 Intergovernmental Coordination and Review Office of Planning 5 Budget Executive Office of the Governor The Capitol Building Tallahassee, Florida 32301 Adminis tra tor Department of'nvironmental Regulation Power Plant Siting Section State of Florida 2600 Blair Stone Road Tallahassee, Florida 32301 Regional Administrator, Region II U.S. Nuclear Regulatory Commission Suite 2900 101 Marietta Street Atlanta, Georgia 30323 Martin H. Hodder, Esquire 1131 NE, 86th Street Miami, Florida 33138 Joette Lorion 7269 SW, 54 Avenue Miami, Florida 33143 Mr. Chris J. Baker, Plant Manager Turkey Point Nuclear Plant Florida Power and Light Company P.O.
Box 029100 Miami, Florida 33102 Attorney General Department of Legal Affairs The Capitol Tallahassee, Florida 32304