Is REVISIONS 8770-G-088 SH 2

NO BY CH APPROVED DESCRIPTION PT 07 2A PT 07 ze PT 07 20 07 20 H

A 106 106 PIS I

I I

~CSAS I

I I

I I

I I

I

~SIAS I

I I

I I

I I

I

~crs ENGINEERING SAFEGUARD PANEL I

IOB PIS I

2 OUT OF 4 LOGIC REACTOR AUXIUARY BUILDING O:,', I ':8 VP~',F)'WIT.'::4 COAITIXML'-"

C0DVC:EFF"?c I la'~z, 36 8/25/97 JCG CM IKL9xm REDRAWN I/14/9 37 9/8/97 JK GM PDB A

CM Hs VFR

~M7:

DEL (C4)

INSTRUMENT BOR¹799:

Aoo: (c4) CLASS BREAK

%9 GM g

~997 t

ADD: (E4,F4 R 04) VALVES, LINES et CLASS BREAKS.

REV: (04)

VENT LOCATION.

39 REFERENCE DRAWINGS 8770-G-078 SH 100 8770-A-051 8770-8-052 8770-8-053 8770-8-231 8770-8-270C

PIPE, VALVE dt INSTRUMENT SIMBOLS VALVE UST UNE UST VALVE OPERATIONAL NUMBER INDEX INSTRUMENT INSTAllATION DETAILS INSTRUMENT LIST NOTE l.

ACIUATOR LOCKED UNJACKED tiU~J.IFR FICG is eccuvttlt &6 et;-N.'4 NOTE; THIS DRAWING IS MADE FROM REV.

OF DRAWING 8770&-088 REVISION OF THIS DRAWING MAY REQUIRE UPDATE OF THE FOLLOWING DOCUMENT:

FSAR FIGURE 6.2-26 NUCLEAR SAFETY RELATED IN PART ONLY FLORIDA POWER Bt UGHT COMPANY ST LUCIE PLANT 1976 890 MWC INSTAllATION UNIT 1

FLOW DIAGRAM CONTAINMENT SPRAY AND REFUELING WATER SYSTEMS FLORIDA POWER et UGHT COMPANY APPROVAL SCALE: NONE DATE:

QAF MECH Ptc J CIRE CFL 0 MQERS 8770-G-088 39 EC CQ m Cap Z

I.

ma fV QG F

--.n()'

EDZ EC 03 Z

ED D

A 106 106I-FT 07 IA PT 07 3A I

V

==Eke FROM SHUTDOWN HX IA 8770-G-078 SH 1308 SI 07 FE-07-IA PAP 86

'e A

106 PT 07 38 FT 07 18 I

V

+an FROM SHUTDOWN HX 18 8770-0-078 SH 1308

?l E7 FE-07-18 FROM SFCD RM IA SUMP PPS 8770-G-088 SH I CS A3 2-CS-74 3/4 Y

FROM REICTQR DRAIN PUMPS 8770-G-078 SH 160A WM F7 CV 2-WM-454 FROM SFCD 119 te SUMP PPS 8770-0 088 SH I CS 83 2-Cs-74 I'R ta EQUIP DRAIN TANK IA 8770-G-078 SH 162A Cs B3 1'R t~-142 vozzal Lo TQ REFCIQR DRAIN PUMPS 8770-G-078 SH teOA SI H4 3-CS-Ml V07200 TO SI Jt Cs PUMPS 8770-0-078 SH 1308 SI 01 1-24-51-504 V07174 TE 07 5A Ta SI k Cs PUMPS 8770-0-078 SH 1308 SI Hl 1-24-5!-506 V07172 TE 07 58 PAP I

07 0

58 INSTRUMENT CABINET 106

~CSAS

-F z89 I

6 8770-G-085 SH 2C (04)

CS PP IA 1EST Ta RWT 8770-C-078 SH 1308 SI 84 t-sl-402 V07158 Y

Eaa V07160 La I-12-CS-11 Fa LO W-07-W 1-12-51-406 LC Y07165 FCV-07-1A SEE NOTE I I

DR 3'Esr I I"3-CS-59 V07207 106 I:I-T 289

~2 8770-0-085 SH 2C (84)

CS PP 18 IEST TO RWT 8770-G-078 SH 1308 SI A5 1-51-401 V07157 Y

~on V07162 La Lo MV-07 38 1-12-51-407 LC V07168 CJ C

V07164 FCV-07-18 SEE NOIE I Ep-.

-=

8 I

~o D

I DR Ta ROIS-25-2A 8770-G-878 3

TEST I V07166 Ta Pals-25-IIA PAP 8770-G-878 PI 07 4A CRAC CRAC PR PIS 07 07 BA BA PT 07 5

PT 0

SE-07-8A TO EROADS/SAS TO POIS-25-28 8770-G-678 106 TO PDIS-25-118 8770~878 PR 07 48 106 PR 07 58 PT 07 48 PT 07 ee 5E-07-88 FROM FUEL POOL IX 8770-G-078 SH 140 Fs E7 3-FS-554 0

8 vozzoe I

LC I-1-CS-62 LINT V07167 I

LC Ta FUEL POOL PURIF 8770-0-078 SH 140 FS Gz V07170 1

OR Jt I-t~-63 llRT V07169 105 105 Cs sze d

gers I Vk lEAK TEST 8770-G-085 SH 2C (D4) 8770-G-D85 SH 2C (D4)

Eb=

Fc Fc I-2-CS-73 LCV-07-11A I

Oe LCV-07-118 PAP-PT 07 5A 106

~ -.-o L

~

INC GUARD PIPE I-24-Cs-5 MV-07-2A 106

':5 Q=.j t

PAP l

Qeer 07

+D I DR 5A FROM ENGD SAFEGUARDS PKL 8770-0-088 SH I E5 GUARD PIPE 1-24-05-4 MV-07-28 lr PO'-I OP PAP PR 07 46 PAP 07 58 PT 07 58 REACTOR AUXIUARY BUILDING

~~ ~ gssel ~~ ~~ ~~ ~~

~~

~N~

~ 5

~N~ ~?~

wwwweeeegl We S HMW a a CONTAINMENT SPRAY HEADERS (178 NOZZlES FOR EACH OF TWO HEADERS) 1-4-05-33 1-3-05-35 18 SPRAY NOZZLES

~

t-e-cs-U 1-4-05-32 1-3-05-34

[-6-CS-16 13 SPRAY NOZZLES I-6-CS-29 1-4CS-31 36 SPRAY NOZZLES 1-6&s-ze I-4-CS-30 38 SPRAY NOZZLES I-6-CS-25 1-4-CS-27 55 SPRAY NQZZLES I-6-CS-24 55 SPRAY NQZZLES I-eCS-zt I-6-CS-23 V07193 69 SPRAY NOZZtES I-6-Cs-20 I6-CS-22 V07192 72 SPRAY NOZZLES O

l)l?

DR I

DR Per 51 45 PAP 07 D7 8

D I

SR07276 45 1-Cs-146 46 1-3-05-52 46 V07189 REFUEUNG CAVITY 8

D I

SR07277 I-CS-146 1-3/4-CS-147 e

0 I

LC 47 I-3-CS-56 1-3-05-54

~vov lsa V07274 V07 188 16-CS-70 HINGED CLOSURE PLATE HINCED CLOSURE PIATE lll C>

f?

CI II CO I-3-CS-114 5

i I

i I

V07275 SIRAINER Ta RX DRN PPS SUCT

~

8770-0-078 SH 160A WM 02 r-e-cs-ee 16 CS-71 FIC 07 6

LT 07 6

I-CS150 LC LC 3-05-511 V07194 V07195 I-3-CS-51 BDA I Y~

I Y

LO Ta ERDADS/SAS 42 CRAC CRAC

--:lC'l,'l8 lU

-6P;-d8 V07220 2-05-42 574 574 g

I I

I Caw Ios I

I Y

I rW~I II I

II I

I DR H

105 A

LS 07 12 LS 06 2

L L

-07 34-4 I

38-4 I

I CONTAINMENT SUMP LE 07

?O FIC 07 3

1 H

~

A 105 RX CAVIIY RX CAVIIY SUMp ptetp IA 5UMp pULp 18 LEAK OEIECTIQN TANK REACTOR CAVITY SUMP

~ ~~ ~~~ ~~%~ ~~ ~ WW ~~ ~~ ~~ ~~ ~~

I I

I 51 53 45

--- I I

I I