ML17340B415

From kanterella
Jump to navigation Jump to search
Forwards Updated LER 79-030/03X-1
Date released: 07/31/2018 Download: ML17340B415


Updated LER 80-030/03X-1:on 791110,during Scram Testing in Refuel Mode,Substantial Loss of Position Indication Noted for Control Rod Driveline H-9.Caused by Improperly Seated Socket,Suggesting Faulty Electrical pin-socket Alignment
ML17340B416
Person / Time
Site: Dresden 
Issue date: 03/26/1980
From:
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17340B416 (2)
Forwards Updated LER 79-030/03X-1
ML17340B414
Person / Time
Site: Dresden 
Issue date: 03/26/1980
From: Stephenson B
COMMONWEALTH EDISON CO.
To: KEPPLER T G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17340B414 (2)