ML17339A595

From kanterella
Jump to navigation Jump to search
Application for Amend to Licenses DPR-31 & DPR-41 Amending Tech Specs to Reflect Results of ECCS Analysis Re Power Distribution Limits for Steam Generator Tube Plugging Level of 22%
ML17339A595
Person / Time
Site: Turkey Point  
Issue date: 02/13/1980
From: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
To:
Shared Package
ML17339A597 List:
References
L-51-80, NUDOCS 8002210436
Download: ML17339A595 (6)


Text

7 REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NB 80022100~

DOC ~ DATE e 80/02/13 NOT~EL'IZED e NO DOCKET FACIL:5 - 50 urkey Point PlantE Unit 3i Florida Power and Light C

05000250 50" 1 Turkey Point Planti Unit Ai Florida Power and Light C

05000251 AUTH ~ NAME AUTHOR AFFILIATION UHRIGE R ~ E ~

F-1orida Power L Light Co, RECAP

~ NAME RECIPIENT AFFILIATION

SUBJECT:

Amend to Licenses DPR-31 8

DRP-Qi amending Tech Specs to, reflect results of ECCS analysis re power distribution limits for steam generator tube plugging level of 22/,

DISTRIBUTION CODE:

AQS9S COPIES RECEIVED:LTR g'ENCL g SIZE:

TITLE: Resp to Lesson Learn Task Force

'Nestinghouse NOTES'~~~WMWMMM~COMMOOWAWtaWAOWrSoSwee eMelete~WWWOal&SWWMWINWAWWMW RECIPIENT ID CODE/NAME ACTION:

10 BC INTERNA :

REG R

PDR 21 KNG BR 23 PLANT SYS BR 25 EFLT TRT SYS NSIC 6

J KERRIGAN 8

C WILLIS M FIELDS OELD EXTERNAL: 26 ACRS COPIES LTTR ENCL

'7 7

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 0

16 16 RECIPIENT ID CODE/NAME I

17 I 8

E 20 CORK PERF BR 22 REAC SFTY BR 24 EKB 3

LPDR 5

J OLSHINSKI 7

J 8URD ION J AT ~

TELFORD

. N ANDERSON P OiREILLY COPIES LTTR FNCL

?

2 1

1 i

1 i

1 i

1 1

1 1

2 2

1 1

i TOTAL NUMBER OF COPIES REQUIRED s LTTR 45 ENCL gccS

I W

O. BOX 529100, MIAMI,FL 33152

~4l rir,. P FLORIDA POWER 4 LIGHTCOMPANY February 13, 1980 L-51-80 Lirector of Nuclear Reactor Regulation Attention:

Nr. Darrell G. Eisenhut, Acting Director Division of Operating Reactors U.

S. Nuclear Regulatory Commission Washington, D.

C.

20555

Dear i~'Ir. Eisenhut:

Re:

Turkey Point Units 3 and 4

Docket Nos.

50-250 and 50-251 Proposed Amendment to Fa'cility

~OI eratirIq Licenses DPR-31 and DPR-41 In accordance with 10'CFR 50-30, Florida Power 8 Light Company submits herewith three (3) signed originals and forty (40) copies of a request to amend Appendix A of Facility Operating Licenses DPR-31 and DPR-43..

Our NSSS vendor (/lestinghouse) has coIIpleted a revised ECCS analysis for Turkey Point Units 3 and 4.

February, 1978 Appendix K evaluation models were used for the worst DECLG break (C>=0.4),

assuming a steam generator plugging level of 22K, a

3X reduction iI tfienIal design flow, and removal of a 65'F fuel temperature conservatism.

The limiting break was reanalyzed at an F

of 1.99 with a resulting peak clad temperature of 2160'F.

The results of th) analysis are presented in Attachment 1.

Justification of the 65'F fuel temperature modification was reviewed by the NRC technical staff and the revised procedure was found to be acceptable for use in Appendix K licensing calcula.ions.

The proposed amendment is described below and shown on the accompanying T chnical Specification pag s bearing the date of this letter in the lower right hand corner.

~Pa es 3.2-3 and 3.2-4 Sp cification 3.2.6.a(2) is revised to reflect ECCS analysis on the power distribution limits plugging level of'2...

the results of a rec.nt for a steam generator tube 8 002318 PEOPLE... SERVING PEOPLE

1

Director of Nuclear Reactor Regulation Page 2

Fl Jul e 3o 2-3 Deleted-This figure is no longer applicable.

The normalized hot channel factor operating envelope for a steam generator tube plugging level of 22'. is revised to reflect the results of a recent ECCS analysis.

An ECCS analysis for 25% steam generator tube plugging is under review and will be submitted shortly.

Specification 3.2.6.a(l) and Figure 3.2-3b have been annotated to indicate that they will be revised based on the results of'he 25/ analysis.

The proposed amendment has been reviewed and approved by the Turkey Point Plant Nuclear Safety Committee and the Florida Power 5 Light Company Nuclear Review Board.

Very truly yours, Ro ert E. Uhrig Vice President-Advanced Systems 8 Technology REU/HAS/cph Attachment cc:

Ilr. J.

P. O'Reilly, Region II Harold Reis, Esquire

'!