UNITED STATES

NUCLEAR REGULATORY COMMISSION

REGION II

101 MARIETTAST., N.W., SUITE 3100

ATLANTA,GEORGIA 30303

Report Nos. 50-250/79-21

and 50-251/79-21

Licensee:

Florida Power

and Light Company

9250 West Flagler Street

Miami, Florida

33101

Facility Name:

Turkey Point Units 3 and

4

Docket Nos. 50-250

and 50-251

License Nos. DPR-31 and DPR-41',

f I

Meeting at

NRC Region II Office, Atlanta, Georgia

Attending Personnel:

See Details

Approved by:

W. A. Ruhlman, Acting Section Chief,'RONS

Meeting Conducted:

June 6,

1979

SUMMARY

Items Discussed

7g

D te Signed

The subject discussed

at this meeting

was the results of the Quality Assurance

inspection conducted

March 12-16 and 19-21,

1979.

DETAILS

1.

Personnel Attendin

Meetin

Florida Power

and Li ht

Com an

(FPL

E. A. Adomat, Executive Vice President

A. D. Uhrig, Vice President

C. 0. Woody, Manager of Power Resources

Nuclear

G. D. Whittier, Senior Engineer

J.

E. Vessley, Director of Quality Assurance

J.

W. Brown, Assistant Manger for QA Applications

Nuclear

Re ulator

Commission

(NRC)

J. P. O'Reilly, Directoi, Region

XX

R.

C,. Lewis, Acting Chief,'eactor

Operations

and Nuclear Support Branch

P. J. Kellogg, Acting Chief, R'eactor Prospects",Section

No.

3

W. A. Ruhlman, Acting Chief, Nuclear Support Section

No.

2

E. H. Verdery, Acting Chief, Reactor

Prospects

Section

No.

2

M. Grotenhuis,

Prospect

Manager of Turkey Point,

NRR

R. J. Vogt-Lowell, Reactor Inspector,

Reactor Projects

Section No.

2

2.

Summar

of Meetin

Held on-June

6

1979

Representatives

of Florida Power and Light Company met with Region IX and

NRR staff personnel at Atlanta, Georgia,

to discuss specific current areas

of concern.

The meeting

was held at the request of the NRC.

Sub]ectsdiscussed

involved the results of the Quality Assurance

Inspection

conducted

March 12-16 and

19-21,

1979, which is contained in Inspection

Report Nos ~ 50-250/79-11

and 50-251/79-11.

Specific concerns in the area

of management

control systems

and the implementation of those

systems

were highlighted

during the meeting~

The need for adequate

procedural

and administrative controls, generic application of corrective actions

implemented in deficient areas,

and timeliness in implementing corrective

actions

were stressed.

The FP&L representatives

were given presentations

by NRC staff members

from the Operations

Branch

These presentations'enerally

summarized

inspection findings at the Turkey Point Units

3 and

4 .facilities and

expounded

on the concerns identified above

The presentations

were given

informally, allowing FP&L representatives

the opportunity to discuss

any aspects

of the

NRC inspection findings and identified concerns.

r

FP&L representatives

acknowledged

the

NRC concerns

and indicated that

corrective action would be implemented in the areas identified.

f