ML17334A953

From kanterella
Jump to navigation Jump to search
Forwards Ping/Sping Particulate,Iodine & Noble Gas Monitor Detector Sys Tech Spec, Discussing Current Noble Gas Monitoring Sys,Per NUREG-0737 Section II.F.1-1.Concurrence W/Sys Requested
ML17334A953
Person / Time
Site: Cook  
Issue date: 04/14/1986
From: Alexich M
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: Harold Denton
Office of Nuclear Reactor Regulation
Shared Package
ML17334A954 List:
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.F.1, TASK-TM AEP:NRC:0678U, AEP:NRC:678U, NUDOCS 8604210103
Download: ML17334A953 (5)


Text

~,ib

)j:GULA(0d 'INl"ORi'lAl'IBM DIBTRIBVTXQli~YSVEI'I '8 JOB)

ACCESSION NBR: 8604210103 DOC. DATE: 86/04/14 NOTARIZED:

NO FACIL: 50-315 Donald C.

Cook Nuclear Power Plant>

Unit 1>

Indiana 50-316 Donald C.

Cook Nuclear Power Plant>

Unit 2.

Ind iana AUTH. MANE AUTHOR AFFILIATION ALEXICH> bf. P.

Indiana 8c Nic h igan El ec tri c Co.

RECIP. NANE RECIPIENT AFFILIATION DENTON, H. R.

Office of Nuclear Reactor Regulation>

Director l

t DOCKET ¹ vo.'500031 5 05000316

< p o st 851125

SUBJECT:

Forjjjards "PING/SPINQ Particulate> Iodine 8< Noble Qas Nonitor Detector Sgs Tech Spec>" discussing current noble gas monitoring sos> per NUREQ-0737 Section II. F. 1-1. Concurrence w/sos requested.

~a DISTRIBUTION CODE:

A006D COPIES RECEIVED: LTR ENCL SIZE:

TITLE:

OR Submittal: Fire Protection NOTES:

RECIP IENT ID CODEINANE PWR-A PD4 PD 01 INTERNAL: ADN/LFNB IE WHITNEY>L NRR PWR-A DIR NRR STANQ> J 07 NRR/DHFT DIR RQN3 COPIES LTTR ENCL 3

3 1

0 1

1 2

2 1

1 RECIPIENT ID CODE/MANE WIGQINQTON> D ELD/HDS3 NRR BWR DIR NRR PWR-8 DIR NRR EIL> J06 EQ FILE 04 COPIES LTTR ENCL 1

1.

0 1

1 0

1 EXTERNAL: 24X NRC PDR LPDR NSIC 03 05 TOTAL NUj~)HER OF COP IES REQUIRED:

LTTR 21 ENCL 18

~i~, J l'

A>f 1

/

E

0 a ~<<so-INOIANA 8 MICHIGAN ELECTRIC COMPANY P.O. BOX 16631 COLUMBUS, OHIO 43216 Anril 14 1986 AEP:NRC:5678U Donald C.

Cook Nuclear Plant Unit Nos.

1 and 2

Docket Nos.

50-315 and 50-316 License Nos.

DPR-58 and DPR-74 NUREG-0737, XI.F.1-1 NOBLE GAS MONITORING SYSTEM TECHNICAL REPORT Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Mr. Denton:

Per Item III of our letter AEP:NRC:0678S, dated February 19,

1986, enclosed is the Eberline Instrument Corporation technical report titled "PING/SPING Particulate, Iodine and Noble Gas Monitor Detector System Technical Specification."

11 1

The purpose of this report is to discuss the current noble gas monitoring system at the Donald C.

Cook Nuclear Plant with respect to NUREG-0737,Section II.F.1-1.

For each channel of the noble gas monitor, the report contains detailed information on the detector system mechanical design, sensitivity, range, linearity and energy response and methods of primary and user calibration.

We believe, based on this report, that the noble gas monitoring system meets the requirements of NUREG-0737,Section II.F.1-1.

Therefore, we request concurrence from the NRC that the detector's range capability, sensitivity, and linearity are sufficient and that further primary calibration of our system is not necessary.

This document has been prepared following Corporate procedures which incorporate a reasonable set of controls to insure its accuracy and completeness prior to signature by the undersigned.

8604210103 860414 PDR ADOCK 05000315I P

. 'DR Very truly yours, P. Alexich ~ $

Vice President MPA/rjn cc:

John E. Dolan W. G.=Smith, Jr.

- Bridgman G. Bruchmann R.

C. Callen G. Charnoff NRC Resident Inspector

- Bridgman OOtII lt

L1 0

e, "t

II t

Eberline A OIVISIQN Qr

~~+

Thermo CORRORA7ION Post Office Box 2108 Santa Fe, New Mexico 87504 2108 Phone: (505) 471.3232 TWX: 9109854678 Telex: 660438 Elc SFE October 31, 1986 Mr. Jim Leichner American Electric Power Service Corporation 1 Riverside Plaza Columbus, OH 432164631 RE: SPING TECHNICALSPECIFICATIONS

Dear Mr. Leichner:

This letter is submitted in r<<sponse to your request for verification that the February 1986 report entitled "PING/SPliVG Particulate Iodine and Noble Gas Monitor Detector Systems T<<chnical Specification" is applicable to the SPING monitors installed at D.C. Cook.

I have reviewed the contents of this report anil can state that the DC. Cook SPING monitors, while not having the full cor>>plement of options discussed in the

report, are still capable of meeting the r<<quiremcnts of NUREG 0737 as discussed in section I of this report.

The in;t~llation of the solid-state mass flow sensor option does not change the linearity, energy response or sensitivity of the monitoring channels.

I will point out that Eberlin<<has spent almost two years collecting additional data on these detector systems to better understand their response to gamma and beta radiations over a

ivide range of energies.

When this data has been completely evaluated.

the Technical Specification report in question will be revised and re-issued.

In particular the energy response of the beta scintil-lation detector will be chang<<d significantly.

Some of the reported sensitivities of gas channels may also cltattge.

These revisions, which should be available in early

1987, are not expected to affect the applicability of these monitors with respect to NUREG 0737.

The final report should give users the necessary information to better predict the detector response to various gaseous isotopic mixtures.

Steven B. Willhoite Systems Sales Manager