Forwards Reactor Containment Bldg Integrated Leak Rate Test,810713-30
ML17334A413
Person / Time
Site: Cook  
Issue date: 08/02/1982
From: Hunter R
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: Harold Denton
Office of Nuclear Reactor Regulation
Shared Package
ML17326A954 List:
References
AEP:NRC:0720, AEP:NRC:720, NUDOCS 8208060172
Download: ML17334A413 (6)


Text

REGULATOR.

INFORMATION DISTRIBUTION uTEM (RIDS)

ACCESSION NBR:8208060172 DOC ~ DATE: 82/08/02 NOTARIZED:

NO DOCKET ¹ FACIL:50 315 Donald C ~

Cook Nuclear power PlantE Unit 1E Indiana 15 50 316 Donald C ~

Cook Nuclear Power PlantE Unit 2i Indiana"S 050003 AUTH'At1E AUTHOR AFFILIATION HUhlTERER ~ SR Indiana 8 Michigan Electric Co ~

AEC IP ~ NAPE RECIPIENT AFFILIATION DENTONEH ~ RE Office of Nuclear Reactor Regulationi Director

SUBJECT:

Forwards "Reactor Containment Bldg Integrated Leak Rate Tes t R" 810713-30

~."

DISTRIBUTION CODE:

AOITS COPIES RECEIVED:LTR l ENCL i SIZE: $ ~ Q TITLE: Containment Leak Rate Testing <<Appendix J

NOTES:

RECIPIENT ID CODE/NAtEE ORB ¹1 BC 01 IYTERhAL: ELD/HDS3 13 NRH/DL/ORAB 10 NR JEST/AEB

~

EG EL 04 COPIES LTTR ENCL 7

7 1

1 1

1 1

1 1

1 REC IP IENT IO CODE/NAPE NRR/DHFS/PTRB08 NRR/OS I/ADCCS11 NRR/OSI/CSB 09 RGN3 COPIES LTTR ENCL 1

1 1

0 1

1 1

1 EXTERNAL: ACRS NRC PDR NTIS 11 10 10 0?

l 1

1 1

LPDR NSIC 03 05 2

2 1

1 TOTAL NUMBER OF COPIES HE4lUIRE.D:

LTTR 30 ENCL 29

INDIANA 5 MICHIGAN ELECTRIC COMPANY P. O. BOX 18 BOWLING GREEN STATION NEW YORK, N. Y. 10004 August 2, 1982 AEP:NRC:0720 Donald C. Cook Nuclear Plant Unit Nos.

1 and 2

Docket Nos. 50-315 and 50-316

'License Nos.

DPR-58 and DPR-74 REACTOR CONTAINMENT BUILDING INTEGRATED LEAK RATE TEST Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555

Dear Mr. Denton:

This letter submits the report of the second periodic Integrated Leak Rate Test (ILRT) for the Donald C. Cook Nuclear Plant Unit 1 Reactor Containment (Attachment No.

1 to this letter).

This report is being submitted in compliance with the requirements of 10 CFR 50, Appendix J.

Please note, however, that the report should have been submitted to you approximately by November 1,

1981.

The precise reasons why it was not submitted are unknown to us at this time, but a Condition Report has been prepared by the Plant to document further investigation of this matter.

We regret any inconvenience this matter may have caused you.

This document has been prepared following Corporate Procedures which incorporate a reasonable set of controls to insure its accuracy and completeness prior to signature by the undersigned.

Very truly yours,

/os R. S. Hunter Vice President cc:(attached) 8208060172 820802 PDR ADGCK 05000315 PDR

Mr. Harold R. Denton AEP:NRC:0720 cc:

John E. Dolan Columbus M. P. Alexich R. W. Jurgensen W. G. Smith, Jr.

Bridgman R. C. Callen G. Charnoff Joe Williams, Jr.

Region IIIResident Inspector - Bridgman

Attachment to AEP:NRC:0720