ML17333B002

From kanterella
Jump to navigation Jump to search
Forwards Response to NRC 970811 Request for Addl Info Re Refueling Operations Decay Time.Responses Contained in Rept Prepared for Licensee by Holtec Intl
ML17333B002
Person / Time
Site: Cook  
Issue date: 08/19/1997
From: Fitzpatrick E
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17333B003 List:
References
AEP:NRC:1202D, NUDOCS 9708250089
Download: ML17333B002 (5)


Text

CATEGORY 1 REGULAT(~ INFORMATION DISTRIBUTIONSTEM (RIDE)

A'CCESSCQN NBR:9708250089 DOC.DATE: 97/08/19 NOTARIZED: YES DOCKET I FACIL:50-315 Donald C.

Cook Nuclear Power Plant, Unit 1, Indiana M

05000315 4>0-3)6 Donald C.

Cook Nuclear Power Plant, Unit 2, Indiana M

05000316

'AUTH.NAME AUTHOR AFFILIATION, FITZPATRECK,E.

American Electric Power Co., Inc.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards response to 970811.NRC facsimile request for addi info re refueling operations decay time. Responses contained in rept prepared for util by Holtec Intl.

DISTRIBUTION CODE:

AOOID COPIES RECEIVED:LTR L ENCL SIZE: 2 +

TITLE: OR Submittal:

General Distribution NOTES:

E RECIPIENT ID CODE/NAME PD3-3 LA HICKMAN,J COPIES LTTR ENCL 1

1 1

1 RECIPIENT ID CODE/NAME PD3-3 PD COPIES LTTR ENCL 1

1 0

INTERNAL E CENTER 1

NRR DE EMCB NRR/DSSA/SPLB NUDOCS-ABSTRACT EXTERNAL: NOAC 1

1 NRR/DE/ECGB/A 1

1 NRR/DRCH/HICB 1

1 NRR/DSSA/SRXB 1

1 OGC/HDS2 1

1 NRC PDR 1

1 1

1 1

1 1

0 1

1 D

0 U

NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD)

ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 13 ENCL 12

0 g:

1s g

I U

II) f 1

II'

Indiana Michigan Power Company 500 Circle Drive Buchanan, Ml 491071395 INDlAMA MlCNJGSlN PQStfkN August 19, 1997 AEP:NRC:1202D Docket Nos:

50-315 50-316 U. S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.

C.

20555 Gentlemen:

Donald C.

Cook Nuclear Plant Units 1 and 2

RESPONSE

TO REQUEST FOR ADDITIONAL INFORMATION REGARDING REFUELING OPERATIONS DECAY TIME This letter and its attachments constitute a

response to the August 11,

1997, NRC facsimile request for additional information regarding our submittal AEP:NRC:1202, dated November 16, 1994.

Our original submittal requested a change in the minimum decay time required after shutdown for movement of irradiated fuel from the core to storage in the spent fuel pool.

Attachment 1 serves as our response to questions 1 through 3.

The responses are contained in a report prepared for us by HOLTEC International.

Attachment 2 is our response to question 4.

Approval of this submittal is required to support the unit 2

5% power uprate (AEP:NRC:1223)

Sincerely, p~j E. E. Fitzpatrick Vice President V

SWORN TO AND SUBSCRIBED BEFORE ME gh THIS /9 DAY OF ~tc ~y, 1997 vlb Notary Public UNDAL BOELCKE Nolory Public, Berrien Counly, Ml MyCommhslon Expires January 21, 2001 Attachment A. A. Bl'nd A. B. Beach MDEQ -

DW Ec RPD NRC Resident Inspector R. Padgett 9708250089 9708i9'DR ADQCK 05000M5 P

PDR llllllllllllllllllllllilllllllllllllllll

I

.J J

-"/

r

-r

/

4 '!W'f'

ATTACHMENT 1 TO AEP:NRC:1202D

RESPONSE

TO QUESTIONS 1 THROUGH 3 REQUEST FOR ADDITIONAL INFORMATION REGARDING REFUELING OPERATIONS DECAY TIME