Forwards 1997 Emergency Plan Exercise Scope & Objectives for 970722 Exercise,Which Will Include Partial State & County Participation
ML17333A872
Person / Time
Site: Cook  
Issue date: 04/22/1997
From: Fitzpatrick E
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
AEP:NRC:0965AL, AEP:NRC:965AL, NUDOCS 9705010212
Download: ML17333A872 (10)


Text

CATEGORY 1 REGULATO ZNFORMATZON DZSTR'ZBUTZON 4EM (RZDS)

ACCESSION NBR:9705010212 DOC.DATE: 97/04/22 NOTARIZED: NO DOCKET FACIL:50-315 Donald C.

Cook Nuclear Power Plant, Unit 1, Indiana M

05000315 50-316 Donald C.

Cook Nuclear Power Plant, Unit 2, Indiana M

05000316 AUTH.NAME AUTHOR AFFILIATION FITZPATRICK,E.

Indiana Michigan Power Co. (formerly Indiana

& Michigan Ele RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Forwards 1997 emergency plan exercise scope

& objectives for 970722 exercise, which will include partial state 6 county participation.

DZSTRZBUTZON CODE:

ZE35D COPZES RECEZVED:LTR I

ENCL l

SZZE:

TITLE: Emergency Preparedness-Appraisal/Confirmatory Action Ltr Ex rc1se Rep NOTES:

RECIPIENT ID CODE/NAME PD3-3 PD INTERNA FILE CENTE ERB RGN3 FILE 01 EXTERNAL: NOAC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 RECIPIENT ID CODE/NAME HICKMAN,J NRR/DISP/P IPB OE DIR NRC PDR COPIES LTTR ENCL 1

1 1

1 1

1 1

1 NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROI DESK (DCD)

ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 9

ENCL 9

Indiana Michigan Power Company 500 Circle Drive Buchanan, Ml 49107 1395 INDIANA NlCHIGAN POWER April 22, 1997 Docket Nos.:

50-315 50-316 AEP:NRC:0965AL 10 CFR 50 App.

E U. S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.

C.

20555 Gentlemen:

Donald C.

Cook Nuclear Plant Units 1 and 2

1997 EMERGENCY PLAN EXERCISE SCOPE AND OBJECTIVES This letter is to inform you that we are submitting the scope and objectives for the July 22, 1997, Cook Iruclear Plant emergency plan exercise to Mr.

James R.

Creed cf your radiological programs section.

This action is in accordance with A.

B. Davis'RC Region III March 16, 1987, letter and FEMA-REP-14, "Radiological Emergency Preparedness Exercise Manual".

The July 22, 1997, exercise will include partial state and county paxticipation.

The exercise will be conducted using the unit 2 simulator and the simulated technical support center in the Cook Nuclear Plant training center.

Controller information and simulation data are also being developed to provide backup for the exercise in the event of simulator equipment problems.

Also, in accordance with FEMA-REP-14, sixty days in advance of the exercise we will submit the complete exercise scenario package with all controller information and simulation data, including plant

data, radiation level data, and release rate data.

Sincerely, E.

E. Fitzpatrick Vice President vlb Attachment A. A. Blind A. B. Beach J.

R. Creed, NRC - Region III - w/attachment MDEQ -

DW 6 RPD NRC Resident Inspector J.

R. Padgett

"'< Oi".1 a 97050i02i2 970422 PDR ADQCK 050003i8 F

PDR IIIIIIIIIIIIIIIIIIIIIIIIIII IIIIlllllll

COOK NUCLEAR PLANT 1997 EMERGENCY PLAN EVALUATEDEXERCISE SCOPE AND OBJECTIVES

PURPOSE The purpose of this emergency preparedness exercise is to meet the conditions of 10CFR50, Appendix E,(IV)(F)(2)(b), which requires a licensee to conduct an exercise of its onsite emergency plan every 2 years.

SCO E

This exercise willtake place between the hours of 0800 and 1400 on July 22, 1997.

It will include actions by the Cook Nuclear Plant, the American Electric Power (AEP) Nuclear Generation Group Headquarters and Engineering Support Groups, AEP St. Joseph, Michigan District Office, and AEP Public Affairs.

State EOC and field survey team operations will be conducted along with Berrien County EOC and field activities.

Some local field demonstations will be conducted out of sequence with the main exercise timeline.

The Cook Plant Unit 2 simulator willbe utilized to drive scenario events and all emergency respcnse facilities will be ac ivated.

They include the Operations Staging Area (OSA),

Simulated Technical Support Center (TSC), Emergency Operations Facility (EOF) and the Joint Public Information Center (JPIC).

Recently implemented NUMARC-based EALs will be utilized in this exercise.

Simulated events at the plant willbegin shortly after 0800. Shortly after that, a turbine first stage pressure transmitter will fail low and cause the reactor control rods to be automatically driven in. The operators will have to assume manual control and call on I

8 C to trip the appropriate bistables within one hour. Concurrent with this, a small break LOCA will occur in ¹3 cold leg and continue to grow until the RCS inventory cannot be maintained with one charging pump.

The unit will now be manually tripped and simultaniously a larger LOCA occurs in ¹4 cold leg; the main turbine will not auto-trip and a loose parts alarm will be received.

Based on loss of fission barriers and/or rising containment radiation levels, an ALERT or SITE AREA EMERGENCY will be declared at this time.

The control room will stabilize the unit and progress toward containment recirculation as the RWST level drops below 35%.

Once on recirculation, the unit will experience a loss of offsite power.

One emergency diesel generator willfail,to start and the other will start but its output breakers willnot close.

Once the output breakers are manually closed, that diesel willbe used to power ECCS loads.

Upon starting the East RHR pump, a break will occur in its suction line from the containment sump creating a pathway for a radioactive release from containment.

This willresult in a GENERAL EMERGENCY. The release will be terminated when a alternate power supply is available and the West RHR pump can be started and the East pump secured.

EXERC SE OBJECTlVES The exercise objectives dictate the scope of the scenario.

The objectives for this exercise were developed based upon the Donald C. Cook Nuclear Plant (DCCNP)

Emergency Plan Administrative Manual.

Situations will be presented in the scenario to prompt the desired player response for each objective.

Where appropriate, specific objectives and criteria for adequate demonstration will be included in the exercise messages for Controller/Observer use.

V L

LI 8

TV 1.

Demonstrate the ability of the emergency response organization to implement DCCNP Emergency Plan Procedures, and the AEP Emergency

Response

Manual.

2.

Demonstrate the ability to establish emergency management command and control, and maintain continuity of this function for the duration of the postulated event.

3.

Demonstrate the ability to establish communications and information flow between DCCNP emergency response facilities and participating offsite agencies.

4.

Demonstrate the ability to designate subsequent shifts of the Emergency

Response

Organization (ERO).

I 8

IV Demonstrate the ability to recognize symptoms and parameters indicative of degrading plant conditions and to classify degraded conditions as emergencies.

2.

Demonstrate the ability to initiate notification of offsite authorities and plant personnel.

3.

Demonstrate communications and information flow to and from the Technical Support Center.

4.

Demonstrate the ability to transfer emergency authorities and responsibilities from the on-shift emergency organization to the DCCNP emergency response organization.

5.

Demonstrate the duties of the Control Room Emergency Organization as described in procedure OHI-2080.

6.

Demonstrate the ability to perform dose projections given appropriate input data.

LS B

V 1.

Demonstrate the ability to activate the facility within one hour of declaration of an emergency requiring facility activation.

I 2.

Demonstrate the ability to provide analytical assistance and operational guidance to the Control Room.

3.

Demonstrate the ability to coordinate onsite activities in response to the emergency.

4.

Demonstrate the ability to establish and maintain hard copy communications with the EOF and verbal communications with the EOF, OSA, HSG, and JPIC.

5.

Demonstrate the ability to provide analytical radiological assistance to the OSA and Control Room.

6.

Demonstrate the ability to obtain data from the Plant Process Computer (PPC).

7.

Demonstrate the ability to request emergency response teams from the OSA.

8.

Demonstrate the ability to evaluate the results of TSC/OSA habitability surveys and assess the need to evacuate these facilities.

9.

Demonstrate the ability to recognize degrading plant conditions and classify plant conditions as an emergency.

10.

Demonstrate the ability to direct the implementation of site

assembly, accountability and evacuation.

11.

Demonstrate the ability to evaluate site evacuation routes and determine an appropriate route based on indicated radiological and meteorological conditions.

12.

Demonstrate the actions required to be taken in the TSC if the emergency involves a breach of the reactor coolant system.

13.

Demonstrate the ability to designate a second shift for TSC operations.

B IVE Demonstrate the ability to activate the facility within one hour of declaration of an emergency requiring facility activation.

2.

Demonstrate the ability to assemble, brief, and dispatch, within an average time of 20 minutes or less after being requested, the following emergency response teams:

at b.

C.

d.

e.

Damage Control Chemistry Sampling Re-Entry and Rescue On-site Radiation Monitoring Off-site Radiation Monitoring 3.

Demonstrate the ability to designate a second shift for OSA operation.

C.

d.

Each emergency response team assembled and dispatched shall demonstrate the following actions as applicable to the team type and mission:

a.

Assembly of tools/equipment; b.

Pre-operation checks of equipment and communications devices; Performance of appropriate radiological precautions; Performance or simulation of team mission; e.

Post-mission debriefing and radiological controls; 5.

Demonstrate the ability to provide emergency radiological support.

As a

minimum, the following activities should be demonstrated:

Establishment of emergency dosimetry and exposure tracking system; Determination and establishment Iif necessary) of emergency control points; C.

Performance of habitability surveys prescribed by procedure; d.

Analysis of radiological conditions to be encountered by emergency

response teams; e.

Specification of radiological controls and precautions for emergency response teams; 6.

Demonstrate the ability to perform offsite radiological monitoring.

As a minimum, two teams should be dispatched and direct radiation monitoring as well as airborne radioactivity analysis should be demonstrated.

7.

Demonstrate the ability to implement damage control activities in accordance with applicable Emergency Plan Procedures.

8.

Demonstrate the ability to perform onsite radiological monitoring in accordance with applicable Emergency Plan Procedures.

This monitoring should include direct radiation surveys and analysis of airborne radioactivity samples.

9.

Demonstrate the ability to obtain post accident samples from one of the following mediums and complete appropriate chemical and isotopic analysis within three hours of the sample request.

a.

RCS Loop b.

Containment Sump 10.

Demonstrate the ability to assess the need for, and process request for potassium iodide administration.

TIVF 1.

Demonstrate the ability to activate the facility within one hour of declaration of an emergency requiring facility activation.

2.

Demonstrate the ability to establish overall command and control of the DCCNP emergency response within one hour of declaration of a site area emergency or higher classification, as applicable.

3.

Demonstrate the ability to establish and maintain effective emergency communications with each of the following agencies and facilities:

a.

b.

C.

d.

State of Michigan Berrien County NRC Technical Support Center

e.

Joint Public Information Center f.

Headquarters Support Group 4.

Demonstrate the ability to establish and maintain hard copy data transmission and reception with each of the following facilities:

a.

Technical Support Center b.

Joint Public Information Center c.

State of Michigan EOC 5.

Demonstrate the ability to direct Offsite Radiation Monitoring Teams in order to determine the geographical location and radiological magnitude of the postulated plume.

6.

Demonstrate the ability to update the State of Michigan on the status of the emergency at 15 minute intervals.

i.

Demonstrate the ability to respond to inquiries from the TSC, JPIC, HSG, and State of Michigan in a timely manner.

8.

Demonstrate the ability to project the magnitude of offsite dose using the Dose Assessment Program.

9.

Demonstrate corporate augmentation of the EOF staff.

10.

Demonstrate recovery planning associated with the emergency termination.

11.

Demonstrate the ability to designate a second shift for EOF operations.

12.

Demonstrate the ability to develop protective action recommendations based on projected dose and/or core and containment status.

V 1.

Demonstra'te activation of the Joint Public Information Center.

2.

Demonstrate the ability to conduct media briefings.

3.

Demonstrate the ability to respond to actual or simulated inquiries from media representatives.

4.

Demonstrate the ability of rumor control personnel to respond to simulated

inquiries from the general public.

5.

Demonstrate the ability to monitor media transmissions and respond to inaccurate information being transmitted by the media.

6.

Demonstrate coordination of news announcement content with State, County and Federal authorities.