Special Rept:On 961119,containment High Range Area Monitor 1-VRA-1410 Declared Inoperable Longer than 7 Days.Caused by Monitor Detector Out of Spec.Detector Replaced
ML17333A693
Person / Time
Site: Cook 
Issue date: 12/03/1996
From: Blind A
AMERICAN ELECTRIC POWER CO., INC.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9612110042
Download: ML17333A693 (2)


Text

CA.lGUV5. X J.

REGULAT

~

INFORMATION DISTRIBUTIO YSTEM (RIDS)

ACCESSION NBR:9612110042 DOC.DATE: 96/12/03 NOTARIZED: NO DOCKET FACIL:50-315 Donald C.

Cook Nuclear Power Plant, Unit 1, Indiana M

05000315 AUTH.NAME AUTHOR AFFILIATION BLINDiA.A.

American Electric Power Co., Inc.

RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Special rept:on 961119,containment high range area monitor 1-VRA-1410 declared inoperable longer than 7 days. Caused by monitor detector out of spec. Detector replaced.

DISTRIBUTION CODE:

IE22D COPIES RECEIVED:LTR J ENCL CI SIZE:

TITLE: 50.73/50.9 Licensee Event Report (LER), Incident Rpt, etc.

NOTES:

INTERNAL:

RECIPIENT ID CODE/NAME PD3-3 PD AB FILE CENg E EELB NRR/DRCH/HHFB NRR/DRCH/HOLB NRR/DRPM/PECB NRR/DSSA/SRXB RGN3 FILE 01 COPIES LTTR ENCL RECIPIENT ID CODE/NAME HICKMANEJ AEOD/SPD/RRAB NRR/DE/ECGB NRR/DE/EMEB NRR/DRCH/HICB NRR/DRCH/HQMB NRR/DSSA/SPLB RES/DET/EIB COPIES LTTR ENCL EXTERNAL: L ST LOBBY WARD NOAC MURPHY,G.A NRC PDR LITCO BRYCEEJ H

NOAC POORE,W.

NUDOCS FULL TXT NOTE TO ALL "RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE!

CONTACT THE DOCUMENT CONTROL DESK, ROOM OWFN SD-5(EXT. 415-2083)

TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

C>

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 25 ENCL 25-

American Electric Powe Cook Nuclear Plant One Cook Place Bndgman. Ml49t06 6]6 465 590t AMER/O'AN KhECKRfC POWER December 3, 1996 Donald C. Cook Nuclear Plant Unit 1 Docket No. 50-315 License No. DPR-58 Special Report Technical Specification 3.3.3.1 United States Nuclear Regulatory Commission Document Control Desk Rockville, Maryland 20852 Gentlemen:

This Special Report is being submitted in accordance with Technical Specification (TS) 3.3.3.1, Table 3.3-6, Action Statement 22A, to inform the NRC that the Unit 1 Containment High Range Area Monitor, 1-VRA-1410, was inoperable longer than 7 days.

On November 19, 1996, at 0835 hours0.00966 days <br />0.232 hours <br />0.00138 weeks <br />3.177175e-4 months <br />, 1-VRA-1410 was declared inoperable when the detector for the monitor was found to be out of specification low during performance of 1 IHP 6030 IMP.312, an 18 month sensitivity verification.

To return the monitor to operable status it was necessary to replace the detector.

A full calibration was performed to adjust the sensitivity settings for the monitor once the new detector was installed.

Repairs and calibrations were completed and the monitor declared operable on November 26, 1996 at 1235 hours0.0143 days <br />0.343 hours <br />0.00204 weeks <br />4.699175e-4 months <br />. The monitor was inoperable for a total time of 7 days, 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

The delay in returning the monitor to operable status is attributed to difficulties in procuring the sealing compound necessary to make the required EQ connection to the new detector.

Due to the short shelf life ofthe compound, it is not normally stocked at the plant. The product was unavailable from the regular supplier and had to be procured from an alternate source.

Use of an alternate supplier required that the product undergo dedication for use in this application, thereby creating a delay in replacement of the detector.

Sincerely, s.u A. A. Blind Site Vice President c:

A.B. Beach, Region III E.E. Fitzpatrick NRC Resident Inspector NFEM Section Chief, State of Michigan 9bi2ii0042 9bi203 PDR ADOCK 050003i5 8