Text
June 3, 19 Dr. Robert U. Mulder, Director University of Virginia Reactor Facility Department of Mechanical, Aerospace and Nuclear Engineering University of Virginia Charlottesville, VA 22903-2442
SUBJECT:
REQUEST FOR ADDITIONALINFORMATION (TAC NO. MA1935)
Dear Dr. Mulder:
1 We are continuing our review of your amendment request for Facility Operating License No. R-123 for the University of Virginia CAVALIERReactor which you submitted on April 6, 1998.
During our review of your ameridment request, questions have arisen for which we require additional information and clarification.
Please provide responses to the enclosed request for additional information within 30 days of the date of. this letter.
In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additional information, we will continue our evaluation of your amendment request.
If you have any questions regarding this review, please contact me at (301) 415-1127.
Docket No. 50-396 Sincerely, ORIGINAL SIGNED BY:
Alexander Adams, Jr., Senior Project Manager Non-Power Reactors and Decommissioning Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation
Enclosure:
As stated cc w/enclosure:
See next page D
B I
ERIC SHolmes Plsaac P Doyle TMichaels TDragoun WEresian MMendonca eelQeezx I'Docket File 50=396 j PUBLIC Region II PDND r/f JRoe (012-E5)
CBassett OGC (015-B18)
AAdams EHylton SWeiss GHill (2) (T5-C3)
TBurdick PDND'
/lJ98 OFFICIAL RECORD COPY
.> 09 9806080147 980608 PDR ADOCK 05000396 PDR
$/g /98 g /P/98 DOCUMENT NAME: G:>SE Y(ADAMS<RAI1935 R..g FLQ gPP)fiji',
4 P
<I~ 11<0O
+Q
~o Cy 0O O
YJ4~
~O
+**++
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 June 3, 1998 Dr. Robert U. Mulder, Director University of Virginia Reactor Facility Department of IVlechanical, Aerospace and Nuclear Engineering University of Virginia Charlottesville, VA 22903-2442
SUBJECT:
REQUEST FOR ADDITIONALINFORMATION(TAC NO. MA1935)
Dear Dr. Mulder:
We are continuing our review of your amendment request for Facility Operating License No. R-123 for the University of Virginia CAVALIERReactor which you submitted on April 6, 1998.
During our review of your amendment request, questions have arisen for which we require additional information and clarification.
Please provide responses to the enclosed request for additional information within 30 days of the date of this letter.
In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. Following receipt of the additional information, we will continue our evaluation of your amendment request.
If you have any questions regarding this review, please contact me at (301) 415-1127.
Sincerely, Alexander Adams, Jr., Senior Project Manager Non-Power Reactors and Decommissioning Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket No. 50-396
Enclosure:
As stated cc w/enclosure:
See next page
4~
4
University of Virginia Docket Nos. 50-62/396 cc:
Department of Environmental Quality Office of Grants Management/Intergovernmental Affairs 629 East Main Street, Sixth Floor Richmond, Virginia 23219 Mr. Preston Farrar Nuclear Reactor Facility School of Engineering and Applied Science University of Virginia Charlottesville, Virginia 22903 Dr. Ronald D. Flack, Jr., Chairman Department of Mechanical, Aerospace and Nuclear Engineering University of Virginia Charlottesville, Virginia 22903 Dr. William Vernetson Director of Nuclear Facilities Department of Nuclear Engineering Sciences University of Florida 202 Nuclear Sciences Center Gainesville, Florida 32611 Dr. Rolan E.
Hertel, Director Neely Nuclear Research Center Georgia Institute of Technology 900 Atlantic Drive, N.W.
Atlanta, Georgia 30332 Mr. Pedro B. Perez, Associate Director Nuclear Reactor Program North Carolina State University P. O. Box 7909 Raleigh, North Carolina 27695-7909 Office of the*Attorney General 101 North 8th Street Richmond, Virginia 23219 Bureau of Radiological Health Division of Health Hazards Control 109 Governor Street, Room 916 Richmond, Virginia 23219
4~
~
ENCLOSURE REQUEST FOR ADDITIONALINFORMATION UNIVERSITYOF VIRGINIACAVALIERREACTOR DOCKET NO. 50-3S6 1.
In technical specification (TS) 6.2, Review and Audit, you have changed the Reactor Safety Committee reporting from the President of the University to the Chair of the committee.
Please justify this proposed change.
2.
In TS 6.6 you have proposed changes to the wording of the introduction of the TS without providing justification.
Please justify your proposed changes.