ML17332A836

From kanterella
Jump to navigation Jump to search
Amend 196 to License DPR-58,adding Footnote to TS 4.6.1.2.a to Provide one-time Extension of Required Test Interval for Overall Integrated Containment Leak Rate Tests
ML17332A836
Person / Time
Site: Cook 
Issue date: 07/06/1995
From: John Hickman
NRC (Affiliation Not Assigned)
To:
Shared Package
ML17332A837 List:
References
NUDOCS 9507120388
Download: ML17332A836 (5)


Text

gPR RE00 a

"o

+a**+

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 INDI NA MICHIGAN POWER COMPANY DOCKET NO. 50-315 DONALD C.

COOK NUCLEAR PLANT UNIT NO.

1 MENDMENT TO FACILITY OPERATING LICENSE Amendment No. i 96 License No. DPR-58 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Indiana Michigan Power Company (the licensee) dated March 17,

1995, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),

and the Commission's rules and regulations set forth in 10 CFR Chapter I;

B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by

. this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

9507i20388 950706 i~)

PDR ADQCK 050003i5 t

PDR

Hr.

E.

E. Fitzpatrick Indiaha Michigan Power Company CC:

Regional Administrator, Region III U.S. Nuclear Regulatory Commission 801 War renville Road Lisle, Illinois 60532-4351 Attorney General Department of Attorney General 525 West Ottawa Street

Lansing, Michigan 48913 Township Supervisor Lake Township Hall P.O.

Box 818 Bridgman, Michigan 49106 Al Blind, Plant Manager Donald C.

Cook Nuclear Plant 1 Cook Place Bridgman, Michigan 49106 U.S. Nuclear Regulatory Commission Resident Inspector's Office 7700 Red Arrow Highway Stevensville, Michigan 49127 Gerald Charnoff, Esquire

Shaw, Pittman, Potts and Trowbridge 2300 N Street, N.

W.

Washington, DC 20037 Mayor, City of Bridgman Post Office Box 366 Bridgman, Michigan 49106 Special Assistant to the Governor Room 1

State Capitol

Lansing, Michigan 48909 Nuclear Facilities and Environmental Monitoring Section Office Division of Radiological Health Department of Public Health 3423 N. Logan Street P. 0.

Box 30195

Lansing, Michigan 48909 Donald C.

Cook Nuclear Plant Hr. S.

Brewer American Electric Power Service Corporation 1 Riverside Plaza

Columbus, Ohio 43215 April 199$

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment,

.and paragraph 2.C.(2) of Facility Operating License No.

DPR-58 is hereby amended to read as follows:

echnical S ec'fications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.

196, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

Attachment:

Changes to the Technical Specifications Date of Issuance:

gu] y 6, 1995 John B. Hickman, Project Manager Project Directorate III-I Division of Reactor Projects III/IV Office of Nuclear Reactor Regulation

ATTACHMENT TO LICENSE AMENDMENT NO."

TO FACILITY OPERATING LICENSE NO.

DPR-58 DOCKET NO. 50-315 Revise Appendix A Technical Specifications by removing the pages identified below and inserting the attached pages.

The revised pages are identified by amendment number and contain vertical lines indicating the area of change.

~EHOV 3/4 6-2 INSERT 3/4 6-2

CONTAINMENT SYSTEMS CONTAINMENT LEAKAGE LIMITING CONDITION FOR OPERATION 3.6.1.2 Containment leakage rates shall be limited to:

a.

An overall integrated leakage rate of cL 0.25 percent by weight of the containment air per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> at P 12.0 psig, and b.

A combined leakage rate of c0.60 L, for all penetrations and valves subject to Types B and C tests when pressurized to P,.

APPLICABILITY: Modes 1, 2, 3 and 4.

ACTION:

Pith either (a) the measured overall integrated containment leakage rate exceeding 0.75 L, or (b) with the measured combined leakage rate for all penetrations and valves subject to Types B and C tests exceeding 0.60 L, restore the leakage rate(s) to within the limit(s) prior to increasing the Reactor Coolant System temperature above 2004F.

SURVEILLANCE RE UIREMENTS 4.6.1.2 The containment leakage rates shall be demonstrated at the following test schedule and shall be determined in conformance with the criteria specified in Appendix J of 10 CFR 50 using the methods and provisions of ANSI N45.4-1972:

a

~

b.

C.

Types A, B, and C (Overall Integrated and Local Combined Leakage Rate) testing shall be conducted in accordance with the requirements specified in Appendix J to 10 CFR 50, as modified by approved exemptions.t Each containment air lock shall be verified to be in compliance with the requirements of Specification 3.6.1.3.

The provisions of Specification 4.0.2 are not applicable.

A one-time extension of the test interval is allowed for the third Type A test of the second 10-year service period originally scheduled to be performed at the end of Cycle 14.

The test will be performed prior to unit restart following the refueling outage that will follow the end of Cycle 15.

COOK NUCLEAR PLANT - UNIT 1 3/4 6-2 AMENDMENT NO. 48,460,457;

) 96