05000315/LER-1980-027-03, /03L-0:on 801218,spent Fuel Pool,Diesel Generator Room Floor & Containment Spring Line Peak Recording Accelerographs Found Out of Calibr.Cause Unknown.Peak Recording Accelerographs Recalibr

From kanterella
(Redirected from ML17331A574)
Jump to navigation Jump to search
/03L-0:on 801218,spent Fuel Pool,Diesel Generator Room Floor & Containment Spring Line Peak Recording Accelerographs Found Out of Calibr.Cause Unknown.Peak Recording Accelerographs Recalibr
ML17331A574
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 01/15/1981
From: Delong S
INDIANA MICHIGAN POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML17326A827 List:
References
LER-80-027-03L, LER-80-27-3L, NUDOCS 8101200371
Download: ML17331A574 (2)


LER-1980-027, /03L-0:on 801218,spent Fuel Pool,Diesel Generator Room Floor & Containment Spring Line Peak Recording Accelerographs Found Out of Calibr.Cause Unknown.Peak Recording Accelerographs Recalibr
Event date:
Report date:
3151980027R03 - NRC Website

text

U. S. NUCLEAR REGULATORY COMMISSION tCENSEE EVENT REPORT QI (PLEASE PRINT OR TYPE ALLREQUIRED INFORMATION) 1Q20 0

0 0

0 0

0 0

p Q3 O~

Q~

14 15 LICENSE NUMBER 26 LICENSE TYPE 30 57 CAT 68 I NRC FO)M 366 t7-77)

~i CON]'ROL BLOCK:

I

~O1 M I D

C C

7 8

9 LICENSEE CODE CON'T KO1 o

cEL~JQ6 p

5 p

3 071 2

1 8

8 0

QB 0 i i 5

8 i

QB 7

8 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE EVENT DESCRIPTION AND PROBABLE CONSEQUENCES Q10

~o 2

DURING A CALXBRATION CHECK OF THE SEISMXC MONITORXNG PEAK RECORDING AND CONTAXNMENT SPRING LINE PRA'S WERE FOUND TO BE OUT OF CALIBRATION.

~o3 ACCELEROGRAPHS

( PRA S )

THE SPENT FUEL POOL I DIESEL GENERATOR ROOM FLOOR THIS CONDITION WAS NONCONSERVATIVE WITH RESPECT TO T.S. 3.3.3.3.

~OB

~OB 80 7

8 9

SYSTEM

CAUSE

CAUSE COMP.

VALVf CODE CODE SUBCODE COMPONENT CODE SUBCODE SUBCODE 011

~NO>>

~E 0>>

N S

T R 'U' L~l0>>

uE 0"

9 10 11

~

12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT LERIRO EVENTYEAR REPORT NO.

CODE TYPE 0 "'""'U0 LJ

~02 7

L~J I0JBJ LIJ LJ 21 22 23 24 26 27 28 29 30 31 ACTION FUTURE EFFECT 8 SHUTDOWN ATTACHMENT NPRDQ PRIME COMP.

TAKEN ACTION ON PLANT METHOD HOURS Q22 SUBMITTED FORM SUB.

SUPPLIER

~@~~~0>>

~z020 LzJQ>>

~On

~YQ24

~O>>

33 34 35 36 37 40 41 42 43 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS Q27 o

THE CAUSE FOR THE PEAK RE 7

8 REVISION LaJ COMPONENT MANUFACTURER 44 47 TELEDYNE GEOTECK 02s MODEL PRA-103)

BEING OUT OF CALIBRATION IS UNKNOWN AT THIS I

THE XNVESTIGATION IS CONTXNUXNG-THE PRA'S WERE RECALIBRATED AND 3

PLACED BACK XN SERVICE.

THE ACTION REQUIREMENT OF T. S.

3. 3. 3. 3. a I

4 WAS FULFILLED CQ ACTIVITY CONTENT RELEASED OF RELEASE AMOUNTOF ACTIVITYQ Z

Q33

~ZQ34 NA 7

8 9

10 44 PERSONNEL EXPOSURES NUMBER TYPE

DESCRIPTION

~oo o O>>~i' 8

9 11 12 13 PERSONNEL INJURIES NUMBER DESCRIPTIONQ41 EK! ~00 00

'A 7

8 9

11 12 LOSS OF OR DAMAGETO FACILITY 43 TYPE

DESCRIPTION

Z Q42 NA 7

8 9

10 PUBLICITY ISSUED DESCRIPTION~

~2O

~NQ44 8

9 10 80 LOCATIONOF RELEASE Q36 NA 45 80 80 80 80 NRC USF ONLY C4O 80' 0a0 t(o/goo37I 68 69 STEVE DEL N PHONE:

NAME OF PREPARER 7

8 9

FACILITY

~3O METHOD OF STATUS 9C POWER OTHER STATUS ~

DISCOVERY DISCOVERY DESCRIPTION Q32 E 0>> ~10 0

Q29 NA

~BQ3>

SURVETLLAN E ES 8

9 10 12 13 44 45 80

(f l

1