ML17331A486
| ML17331A486 | |
| Person / Time | |
|---|---|
| Site: | Cook |
| Issue date: | 09/30/1980 |
| From: | James Keppler NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Dolan J AMERICAN ELECTRIC POWER CO., INC., INDIANA MICHIGAN POWER CO. |
| References | |
| NUDOCS 8010160230 | |
| Download: ML17331A486 (1) | |
Text
SKP SO j980 Docket No. 50-315 Docket No. 50-316 American Electric Power Service Corporation Indiana and Michigan Power Company ATTN:
Mr. John E. Dolan Vice Chairman Engineering and Construction 2 Broadway New York, NY-10004 Gentlemen:
Enclosed is IE Supplement No.
2 to Bulletin No.79-01B.
This information is presented in the form of generic questions and answers which will assist you in responding to the actions required in IEB-79-01B and the Memorandum and Order (CLI-80-21) dated May 23, 1980 with regard to environmental qualification of Class lE equipment in use at your power reactor facilities with an operating license.
Should you have questions regarding this Supplement please contact this office.
Sincerely, James G. Keppler Director
Enclosure:
IE Supplement No.
2 to Bulletin No.79-01B cc w/encl:
Mr. D. V. Shaller, Plant Manager Central Files
- Director, NRR/DPM
- Director, NRR/DOR AEOD Resident Inspector, RIII PDR I,ocal PDR NSIC TIC Ronald Callen, Michigan Public Service Commission RIII Hei an/np 9/30/80 gg yp ygip250 RIII Kep ler
aa