1980 DISTRIBUTION NOVEMBER e
Docket Files 5-and 6
NRC PDRs (2)
Local PDR TERA Docket Nos. 50-315 NSIC and 50-316 NRR Reading ROB1 Reading T. Novak S.
Varga Mr. John Dolan, Vice President S. Miner, Indiana and Michigan Electric Company C. Parrish Post Office Box 18 J.
Roe Bowling Green Station J.
Heltemes New York, Ne>> York 10004 I&E (3) cc'ELD
Dear Mr. Dolan:
In accordance with the request in your letter of May 30, 1980, we are enclosing a copy of the report prepared by Our consultant, Dr. Harstead, on his estimate of the ultimate pressure capacity of the containment
, structure.
Me would appreciate receiving any comments you may have on the report.
In addition, we recommend that as soon as you have had time to review the report, you contact us to arrange a meeting between our staffs to discuss the enclosed report as well as the studies you are making on the same topic.
Sincerely,
'l'<g~nal signeQ bye S. A-Varga F. Schauer F. Rinaldi CQg P3
~
i~1'R cp t
Enclosure:
Estimate of Ultimate Pressure Capacity of Containment Structure cc'.
w/enclosure See next page Steven A. Varga, Chief Operating Reactors Branch 01 Division of Licensing OFFICES DL rORB1 svR E
.. $NlO.Qe; j.b 11/5 J80 NRC FORM 318 (9 76) NRCM 0240 ip DL:ORB1 a,.g
/80.
4 U.S. GOVERNMENT PRINTING OFFICE: 1979 289 369-
g r
II f
11 t
I;t C;
C' lrll ~,
I
0
,I 4y
~O lO0
+ ~~*<<+
c~
i4~<~
n 4
UNlTED STATES NUCLEAR REGULATORY COMM(SSlON WASHINGTON, D. C. 20555 November 6, 1980 Docket Nos. 50-315 a
6 Mr.. John Dolan, Yice President Indiana and Michigan Electric Company Post Office Box 18 Bowling Green Station New York, New York 10004
Dear Mr. Dolan:
In accordance with the request in your. letter of May 30,'1980, we are enclosing a copy of the report prepared by our consultant, Dr. Harstead, on his estimate of the, ultimate pressure capacity of the containment structure.
We would appreciate receiving any comments you may have on the report.
In addition, we recommend that as soon as you have had time to review the report, you contact us to arrange a meeting between our staffs to discuss the enclosed report as well as the studies you are making on the same topic.
Sincerely, even A.
- rga, Operating Reactors ch 81 Division of Licensing
Enclosure:
Estimate of Ultimate Pressure Capacity of Containment Structure (sec~>-5IS ~~ I cc:
w/encl osure See next page
Mr. John Dolan Indiana and Michigan Electric Company November 6, 1980 CC:
Mr. Robert N. Jurgensen Chief Nuclear Engineer American Electric Power Service Corporation 2 Broadway New York, New York 10004 Gerald Charnoff, Esquire Shaw, Pittman, Potts and Trowbridge 1800 M Street, N.W.
'Hashington, D.
C.
20036 Citizens for a Better Environment 59 East Van Buren Street Chicago, Illinois 60605 Maude Preston Palenske Memorial Library 500 Market Street St. Joseph, Michigan 49085 Mr. D-Shaller, Plant Manager Donald C.
Cook Nuclear Plant P. 0.