Forwards SE Granting Relief Requests Contained in 910409 & 1105 Submittals from Testing Requirements for Applicable ESW Valves for 1 Yr or Until Next Outage
ML17331A069
Person / Time
Site: Cook  
Issue date: 02/19/1993
From: Marsh L
Office of Nuclear Reactor Regulation
To: Fitzpatrick E
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
Shared Package
ML17331A070 List:
References
TAC-M80462, TAC-M80463, NUDOCS 9303030309
Download: ML17331A069 (4)


Text

%OR Rfcu, (4

~4 0

o

~O

%y*y4 Docket Nos.

50-315 and 50-316 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 205554001 February 19, 1993 Hr.

E.

E. Fitzpatrick, Vice President Indiana Hichigan Power Company c/o American Electric Power Service Corporation 1 Riverside Plaza

Dear Hr. Fitzpatrick:

SUBJECT:

IN-SERVICE TESTING (IST)

PROGRAH RELIEF REQUESTS, D.

C.

COOK NUCLEAR PLANT UNITS 1

AND 2 (TAC NOS.

H80462 AND H80463)

By letters dated April 9 and November 5, 1991, you provided a response to NRC Inspection Reports 50-315/90201 and 50-316/90201, regarding the operational readiness of the essential service water (ESW) system at D.

C.

Cook Nuclear Plant Units 1 and 2.

In particular, you submitted revisions 3A and 3B to the D.

C.

Cook IST program to address the closed safety function of various valves in the ESW system and several interacting systems.

Included within these revisions were two requests for relief of IST program requirements.

Enclosed is the Safety Evaluation for the relief requests contained in your submittals.

The staff has reviewed and evaluated the relief requests and grants relief from the testing requirements for the applicable ESW valves for one year or until the next outage, whichever is later, to allow you to determine if an appropriate non-intrusive means of determining valve position is possible.

You co'mmitted in your letter of November 5, 1991, to evaluate testing methods for determining valve position, including non-intrusive methods.

The ESW valves should be considered in these efforts.

Please provide us with your evaluation of alternate testing methods for these valves.

With respect to the relief request associated with verifying the closed safety function of the check valves in the lines supplying the containment spray header; the staff concurs with your assessment.

Therefore, relief is granted as requested.

9303030309 9302i9 PDR ADOCK 050003i5 P

'DR'it" 1

Hr.

E.

E. Fitzpatrick February 19, 1993 This submittal completes the staff's actions under TAC numbers H80462 and M80463. If you have any questions, please contact me at 301-504-1340.

Sincerely,

Enclosure:

Safety Evaluation-

'c w/enclosure:

See next page DISTRIBUTION PD31 Rdg File T. Hurley/F. Hiraglia 12/G/18 J. Partlow 12/G/18 E. Rossi 9/A/2-J.

Lieberman 7/H/5 JRoe JZwolinski LMarsh J.

Norberg 7/E/23 E. Jordan HNBB-3701 G. Hill(4)

F. Grubelich 7/E/23 OPA OC/LFDCB WShafer RIII Cook P/F HShuttleworth WDean OGC ACRS(10)

G. Grant 17/G/21 Origirml~ by Ledyard B. Marsh, Director Project Directorate III-1 Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation

  • See revious concurrence DOCUMENT NAME: G:

WPDOCS COOK C080462.REL OFFICE PDI II-1: LA PDI

-1: PM OGC PD III-1' DATE HShuttleworth 02 11 93*

vsb 02 93 JHull 02/12 93*

LMarsh 02 tR 93

0 I'

i r

't f

I 1

Mr. E.

E. Fitzpatrick Indiana Michigan Power Company CC:

Regional Administrator, Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Attorney General Department of Attorney General 525 West Ottawa Street Lansing, Michigan 48913 Township Supervisor Lake Township Hall Post Office Box 818 Bridgman, Michigan 49106 Al Blind, Plant Manager Donald C.

Cook Nuclear Plant Post Office Box 458 Bridgman, Michigan 49106 U.S. Nuclear Regulatory Commission Resident Inspector Office 7700 Red Arrow Highway Stevensville, Michigan 49127 Gerald Charnoff, Esquire

Shaw, Pittman, Potts and Trowbridge 2300 N Street, N.

W.

Washington, DC 20037 Mayor, City of Bridgman Post Office Box 366 Bridgman, Michigan 49106 Special Assistant to the Governor Room 1

State Capitol

Lansing, Michigan 48909 Nuclear Facilities and Environmental Monitoring Section Office Division of Radiological Health Department of Public Health 3423 N. Logan Street P. 0.

Box 30195

Lansing, Michigan 48909 Donald C. Cook Nuclear Plant Mr. S. Brewer American Electric Power Service Corporation 1 Riverside Plaza
Columbus, Ohio 43216