CRITICALITYANALYSIS OF THE DONALD C. COOK NUCLEAR PLANT FUEL RACKS REGION 1 CHECKERBOARD OF BURNED & FRESH FUEL ASSEMBLIES November 1990 M. W. Fecteau T. L. Signorella W. P. Kovacik J.

R. Seeker F. K. Torres 9102250099 9i02i5 PDR ADOCK 050003i5 P

PDR

TABLE OF CONTENTS 1.0 Introduction 1.1 Design Description 1.2 Design Criteria

~

~

~

~

~

~

~

1

~

\\

~

~

2.0 Analytical Methods 2.1 Criticality Calculation Methodology 2.2 Reactivity Equivalencing Methodology

~

~

3

~

~

~

~

~

~

~

~

~ 4 3.0 Criticality Analysis of Region 1 Checkerboard 3.1 KENO Reactivity Calculations 3.2 PHOENIX Reactivity Equivalencing 3.3 Postulated Accidents 3.4 Sensitivity Analysis 4.0 Summary of Criticality Results Arrangement..........

6

~

~

~

~

~

~

~

~

~ 6 I'

~

~

~

~

~

~

~

r'

~

9

~

~

~

~

~ 9

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

~

10 Bibliography 25 Table of Contents

LIST OF TABLES Table Table Table Table Table

1. Fuel Parameters Employed in Criticality Analysis
2. Benchmark Critical Experiments

[5,6]

3. Comparison of PHOENIX Isotopics Predictions to Yankee Measurements
4. Benchmark Critical Experiments PHOENIX Comparison
5. Data for U Metal and UO~ Critical Experiments 12 13 Core 5

14 15 16 List of Tables

1 p

1

,I

LIST OF ILI USTRATIONS Figure Figure Figure Figure Figure Figure Figure

1. Donald C. Cook Nuclear Plant Spent Fuel Pool Storage Cell Nominal Dimensions

~

~

~

1

~

2. Donald C. Cook Nuclear Plant SFP Region 1 Checkerboard Fuel Assembly Loading Schematic
3. Donald C. Cook Nuclear Plant Schematic for SFP Interface Boundary Between Regions 1 and 2
4. Donald C. Cook Nuclear Plant SFP Region 1 "Burned" Fuel Assembly Minimum Burnup vs. initial U Enrichment Curve
5. Sensitivity of k~<< to Enrichment in the Donald C. Cook Nuclear Plant SFP Region 1 Storage Area with Checkerboard Loading
6. Sensitivity of ke<< to Center-to-Center Spacing in the Donald C.

Cook Nuclear Plant SFP Region 1 Storage Area with Checkerboard Loading

7. Sensitivity of ke<< to 8 Loading in the Donald C. Cook Nuclear Plant SFP Region 1 Storage Area with Checkerboard Loading 18 19 20 21 22 23 24 List of Illustrations

L

'C lt g S,

I 5

1.0, INTRODUCTION This report presents the results of a criticality analysis of the Donald C. Cook Nuclear Plant Spent Fuel Pool (SFP) storage rack for the storage of Westinghouse and ANF (Advanced Nuclear Fuel) 15x15 and 17x17 fuel assemblies, This analysis considers a checkerboard arrangement of burned and fresh fuel assemblies within the SFP Region 1

area.

I ls The Donald C. Cook Nuclear Plant SFP storage rack was previously analyzed for the storage of Westinghouse 15x15 and 17x17 fuel as two separate spent fuel arrays or regions.

Region 1 was analyzed for nominal enrichments up to 4.95 w/o U

using a

three out of four fuel assembly storage arrangement.

335 Region 2 was analyzed for nominal enrichments up to 3.95 w/o U

using all available storage cells.

Enrichments greater than 3.95 w/o were also allowed

'n the Region 2 area, provided restrictions on burnup were met.

This report describes an alternate fuel assembly storage arrangement for the Region 1

area which utilizes all available storage locations.

This arrangement regains the twenty-five percent storage cell loss of the previous three out of four storage arrangement, by checkerboarding burned and fresh fuel assemblies together within the same region.

Burnup credit, which takes into consideration the changes in fuel and fission product inventory resulting from depletion in the reactor core, will be used to establish the burnup requirements of the burned fuel assemblies in the checkerboard.

The criticality and burnup credit analysis of the checkerboard arrangement is presented in Section 3 of this report.

This Donald C. Cook Nuclear Plant SFP criticality analysis is based on main-taining kyar~ 5 0.95 for storage of Westinghouse 15x15 STD (Standard) and OFA (Optimized Fuel Assembly),

17x17 STD, OFA and VANTAGE 5, and ANF 15x15 and 17x17 fuel assemblies.

The fuel parameters relevant to this analysis are given in Table 1 on page 12.

1.1 DESIGN DESCRIPTION The Donald C. Cook Nuclear Plant SFP storage cell design is depicted sche-matically in Figure 1 on page 18 with nominal dimensions given on the figure.

The Region 1 checkerboard arrangement of burned and fresh fuel assemblies is shown in Figure 2 on page 19 and an example of the interface boundary be-Introduction

'1 sE l

J

tween the Region i checkerboard and existing Region 2 storage areas is given in Figure 3 on page 20.

The total number of SFP locations designated as Region 1 or 2 is left to the utility to determine.

The boundary between the two regions can be drawn anywhere within the SFP racks, but the interface must be configured such that there is a one row carryover of the pattern established in Region 1 into Region This assures that the pattern of fuel assemblies at the interface will not be more reactive than the patterns allowed on either side of the boundary.

Figure 3

on page 20 illustrates. the Region 1 to 2 boundary interface.

In this figure, the horizontally-lined boxes represent Region 1 "fresh" fuel storage lo-235 cations which are qualified for fresh fuel enrichments up to 5.0 w/o U The diagonally-lined boxes represent Region 1 "burned" fuel storage locations which are qualified for storage of fuel assemblies which satisfy the Region 1

burnup-enrichment requirements of Figure 4 on page 21.

The blank boxes "rep-resent Region 2 fuel assembly storage locations which are qualified for storage of fuel assemblies which satisfy the Region 2 enrichment-burnup requirements as reported in the previous criticality report In this figure, the checkerboard pattern of Region 1 burned assemblies

{diagonally-lined boxes) has been carried into the Region 2

area by one row.

The remaining cells in the first row of Region 2 are then filled with fuel assemblies which meet the requirements for storage in Region 2 (blank boxes).

In this way, the requirements for fuel as-sembly storage in both regions are satisfied, and any grouping of four assem-blies at the interface boundary will always be less than or equal in reactivity to similar groups of four assemblies allowed on either side of the boundary.

1.2 DESIGN CRITERIA Criticality of fuel assemblies in a fuel storage rack is prevented by the design of the rack which limits fuel assembly interaction.

This is done by fixing the minimum separation between fuel assemblies and inserting neutron poison be-tween fuel assemblies.

The design basis for preventing criticality outside the reactor is that, including uncertainties, there is a 95 percent probability at a 95 percent confidence level that the effective neutron multiplication factor, kyar~, of the fuel assembly array will be less than 0.95 as recommended by ANSI. 57.2-1983 and Reference 2.

Introduction

'I pL

2.0 ANALYTICALMETHODS 2.1 CRITICALITY CALCULATION METHODOLOGY The criticality calculation method and cross-section values are verified by comparison with critical experiment data for fuel assemblies similar to those for which the racks are designed.

This benchmarking data is sufficiently diverse to establish that the method bias and uncertainty will apply to rack conditions which include strong neutron absorbers, large water gaps and low moderator densities.

The design method which insures the criticality safety of fuel assemblies in the spent fuel storage rack uses the AMPX 'ystem of codes for cross-section generation and KENO IV for reactivity determination, The 227 energy group cross-section library that is the common starting point for all cross-sections used for the benchmarks and the storage rack is generated from ENDF/B-V'ata.

The NITAWL program

includes, in this
library, the self-shielded resonance cross-sections that are appropriate for each particular geometry.

The Nordheim Integral Treatment is used.

Energy and spatial weighting of cross-sections is performed by the XSDRNPM'rogram which is a one-dimensional S~ transport theory code.

These multigroup cross-section sets are then used as input to KENO IV'hich is a three dimensional Monte Carlo theory program designed for reactivity calculations, A set of 33 critical experiments has been analyzed using the above method to demonstrate its applicability to criticality analysis and to establish the method bias and uncertainty.

The experiments range from water moderated, oxide fuel arrays separated by various materials (B4C, steel, water, etc) that simulate LWR (Light Water Reactor) fuel shipping and storage conditions to

dry, harder i7i spectrum uranium metal cylinder arrays with various interspersed materials (Plexiglas and air) that demonstrate the wide range of applicability of the method.

Table 2 on page 13 summarizes these experiments.

The average ke~t of the benchmarks is 0.992 The standard deviation of the bias value is 0.0008 bk.

The 95/95 one sided tolerance limit factor for 33 values is 2.19.

Thus, there is a

95 percent probability with a

95 percent confidence level that the uncertainty in reactivity, due to the method, is not greater than 0.0018 Ik.

Analytical Methods 3

1 r

k Av I"

IIII

group nuclear data library based on a modified version of the British WIMS library is used with PHOENIX.

A study was done to examine fuel reactivity as a function of time following discharge from the reactor.

Fission product decay was accounted for using CINDER' CINDER is a point-depletion computer code used to determine fission product activities.

The fission products were permitted to decay for 30 years after discharge.

The fuel reactivity was found to reach a maximum at approx-imately 100 hours0.00116 days <br />0.0278 hours <br />1.653439e-4 weeks <br />3.805e-5 months <br /> after discharge.

At this

time, the major fission product poison, Xe, has nearly completely decayed away.

Furthermore.

the fuel re-activity was found to decrease continuously from 100 hours0.00116 days <br />0.0278 hours <br />1.653439e-4 weeks <br />3.805e-5 months <br /> to 30 years fol-lowing dischaige.

Therefore, the 'most reactive time for a fuel assembly after discharge from the reactor can be conservatively approximated by removing the X

The PHOENIX code has been validated by comparisons with experiments where the isotopic fuel composition has been examined following discharge from a

reactor.

In addition, an extensive set of benchmark critical experiments has been analyzed with PHOENIX.

Comparisons between measured and predicted uranium and plutonium isotopic fuel compositions are shown in Table 3 on page 14.

The measurements were made on fuel discharged from Yankee Core 5

The data in Table 3 on page 14 shows that the agreement between PHOENIX predictions and measured isotopic compositions is good.

The agreement between reactivities computed with PHOENIX and the results of 81 critical benchmark experiments is summarized in Table 4 on page 15.

Key parameters describing each of the 81 experiments are given in Table 5 on page 16, These reactivity comparisons again show good agreement between exper-iment and PHOENIX calculations.

Since the burnup history of fuel assemblies which will be discharged in the future is not known exactly, a reactivity uncertainty is applied to the burnup-dependent reactivities computed with PHOENIX.

An uncertainty which increases linearly with burnup to 0.01 4k at 30,000 MWD/MTU is applied to the PHOENIX calculational results in the development of the Region 1 burnup requirements.

Analytical Methods

1 p

0

This uncertainty is considered to be very conservative and is based on con-sideration of the good agreement between PHOENIX predictions and measure-ments (comparison results with the Yankee Core experiments and S1 benchmark experiments are given in Table 3 on page 14 and Table 4 on page

15) and on conservative estimates of fuel assembly isotopic buildup variances.

For the Donald C. Cook Nuclear Plant SFP Region 1 analysis, the PHOENIX calculations for the maximum burnup of 31,000 MWD/MTU include a reactivity uncertainty of 0.0103 Dk.

Analytical Methods 5

C3 I

,l~

>V, J

(A

+

3.0 CRITICALITYANALYSIS OF REGION 1

CHECKERBOARD ARRANGEMENT This section develops and describes the analytical techniques and models em-.

ployed to perform the criticality and reactivity equivalencing analysis for stor-age of fuel in the Donald C. Cook Nuclear Plant Spent Fuel Pool (SFP) Region 1 area.

This analysis considers a checkerboard arrangement of burned and fresh fuel assemblies within the SFP Region 1 area.

Section 3,1 describes the KENO reactivity calculations for the checkerboard ar-rangement of burned and fresh fuel assemblies.

For the KENO analysis, the "burned" fuel assemblies will be represented by fresh fuel assemblies with a

low enrichment.

Section 3.2 will then describe the PHOENIX reactivity equiv-alencing analysis which will establish the burnup requirements of the "burned" fuel assemblies in the checkerboard.

Section 3.3 will discuss postulated acci-dents and Section 3.4 will present the results of the PHOENIX sensitivity cal-culations for enrichment, cell center-to-center

spacing, and poison loading, 3.t KENO REACTIVITY CALCULATIONS The following assumptions are used to develop the nominal case KENO model for checkerboard storage of burned and fresh fuel assemblies in, the Region 1

area (refer to Figure 2 on page 19 for layout).

1.

Westinghouse 17x17 OFA fuel assemblies with nominal enrichments of 5.0 w/o U are. modelled in the "fresh" fuel storage locations of the check-erboard.

The enrichment of 5.0 w/o U

was chosen to conservatively bound all present and future fuel assembly enrichments.

Evaluation of the Westinghouse 15x15" and 17x17 and ANF 15x15 and 17xl7 fuel assemblies shows that the Westinghouse 17x17 OFA fuel assembly is the most reactive fuel type at this enrichment.

The Westinghouse 17x17 VANTAGE 5 fuel design parameters relevant to the criticality analysis are the same as the OFA parameters and will yield equivalent results.

Therefore, only the Westinghouse 17x17 OFA 'uel assembly is analyzed in the "fresh" fuel checkerboard locations (see Table 1 on page 12 for fuel parameters).

2.

Westinghouse 17xl7 STD fuel'assemblies with nominal enrichments of 2.3 w/o U are modelled in the "burned" fuel storage locations of the check-erboard.

Evaluation of the Westinghouse 15x15 and 17x17 and ANF 15xl5 Criticality Analysis of Region 1 Checkerboard Arrangement

and 17x17 fuel assemblies shows that the Westinghouse 17x17 STD fuel assembly is more reactive than other Westinghouse 17xl7 and ANF 15x15 and 17x17 fuel types and approximately equivalent (within 0.0015 hk) to the Westinghouse 15x15 fuel assembly at this enrichment.

Therefore, only the Westinghouse 17x17 STD fuel assembly is analyzed in the "burned" fuel checkerboard locations (see Table 1 on page 12 for fuel parameters).

3.

All fuel assemblies contain the highest authorized enrichment over the finite 144 inch length of each rod, are at the most reactive point in life, and no credit is taken for any burnable absorber in the fuel rods or any natural enrichment axial blankets.

These assumptions result in conservative calcu-lations of reactivity.

4.

The fuel pellets are assumed to be at 96% of theoretical

density, and no credit is taken for dishing or chamfering.

5.

No credit is taken for any U

or U in the fuel, nor is any credit taken for the build up of fission product poison material.

6.

The moderator is pure water at a temperature of 68'F. A-conservative value of 1.0 gm/cm is used for the density of water.

7.

No credit is taken for any spacer grids or spacer sleeves.

8.

All available fuel cells are utilized.

Fuel assemblies are arranged in a

checkerboard

pattern, as depicted in Figure 2 on page 19.

9.

The array is infinite in lateral extent and finite in axial extent which allows neutron leakage from only the axial direction.

10.

The minimum poison material loading of 0.02 grams 8

per square centi-meter is used throughout the array.

The KENO calculation for the nominal case resulted in a ke<<of 0.8932 with a 95 percent probability/95 percent confidence level uncertainty of +0.0045.

The nominal case result can be compared to the 'worst case result to determine the relative impact of applying the worst case assumptions.

The nominal case is also used as the center point for the sensitivity analysis discussed in Section 3.4.

The maximum k~r~ under normal conditions arises from consideration of me-chanical and material thickness tolerances resulting from the manufacturing process in addition to asymmetric positioning of fuel assemblies within the storage cells.

Westinghouse internal studies of asymmetric positioning of fuel assemblies within the storage cells have shown that symmetrically placed fuel assemblies yield equal or conservative results in rack ke<<.

The sheet metal tolerances are considered along with construction tolerances related to the cell I.D., and cell center-to-center spacing.

For the Region 1 racks.

this results in the reduction of the nominal center to center spacings.to their minimum values.

Criticality Analysis ot Region 1 Checkeiboard Arrangement

8 t

23s Furthermore, fuel enrichments are increased by 0.05 w/o U to conservatively account for enrichment variability.

Enrichments are assumed to be 5.05 w/o U

for the "fresh" fuel cells and 2.35 wlo U for the "burned" fuel cells.

Thus, the "worst case" KENO model of the Region 1

storage racks contains minimum center to center

spacings, symmetrically placed fuel assemblies, and maximum fuel assembly enrichments.

Based on the analysis described

above, the following equation is used to de-velop the maximum kett for the Donald C.

Cook Nuclear Plant SFP Region 1

racks:

kett

= kworst

~

Bmetrtoo

~

Boert

~

Besm l [ (ks) worst

~ (ks)'metrtoo

]

where:

kwarst worst case KENO ke<< that includes material tolerances, and mechanical tolerances which can result in spacings between fuel assemblies less than nominal Bmethoo

=

method bias determined from benchmark critical comparisons Bpert Besm bias to account for poison particle self-shielding.

This standard term accounts for the increased neutron transmission through the poison plate due to the inherent effects of poison particle self-shielding, and has been analytically determined for poison plates similar to those used in this analysis.

bias to account for the reactivity difference between the Region 1

SFP "burned" checkerboard locations loaded with Westinghouse 17x17 STD fuel assemblies at 2.3 w/o U'ersus Westinghouse 15x15 fuel assemblies at 2.3 w/o U ksworst

=

95/95 uncertainty in the worst case KENO. ke<<

ksmettoo

=

95/95 uncertainty in the method bias Substituting calculated values in the order listed above, the result is:

kett

= 0.9295

+ 0.0083

+ 0.0014

+ 0.0015

+ l[(0.0044) i (0.0018)

]

= 0.9455 Since ketf is less than 0.95 including uncertainties at a

95/95 probability/confidence level, the acceptance criteria for criticality is met for the Region 1 checkerboard arrangement of "fresh" fuel cells at a nominal enrichment of 5.0 w/o U

and "burned" fuel cells at a nominal enrichment of 2.3 w/o U235 Criticality Analysis of Region 1 Checkerboard Arrangement

\\

I I

I It

3.2 PHOENIX REACTIVITY EQUIVALENC!NG Spent fuel storage.

in the Region 1 checkerboard

area, is achievable by means of the concept of reactivity equivalencing.

The concept of reactivity equiv-alencing is predicated upon the reactivity decrease associated with fuel de-pletion.

A series of reactivity calculations are performed to generate a set of enrichment-fuel assembly discharge burnup ordered pairs which all yield the equivalent ke<<when the fuel is stored in the Region 1 "burned" fuel storage cells.

The maximum k~<< for storage of spent fuel in the Region 1 checkerboard area is determined using the methods described in Section 2.

Figure 4 on page 21 represents combinations of fuel enrichment and discharge burnup yielding the same rack multiplication factor (ki<<) as the rack loaded with a "checkerboard of 5.0 w/o U fuel in the "fresh" fuel cells and 2.3 w/o U fuel (at zero burnup) in the "burned" fuel cells.

This curve was obtained by first calculating the equivalent reactivity points using PHOENIX and then normalizing the points to the nominal KENO calculation described in Section 3.1

~

The uncertainty associ-ated with the reactivity equivalence methodology is included in the development of the burnup requirements.

This uncertainty was discussed in Section 2.2.

Figure 4 on page 21 shows the constant ke<<contour generated for the Donald C. Cook Nuclear Plant Region 1 checkerboard.

Note in Figure 4 on page 21 the endpoint at 0, MWD/MTU where the enrichment is 2.3 w/o, and at 31,000 MWD/MTU where the enrichment is 5.0 w/o.

The interpretation of the endpoint data is as follows: the reactivity of the Region 1 checkerboard rack containing 5.0 w/o U fuel at zero burnup in the "fresh" fuel cells and 5.0 w/o U

fuel at 31,000 MWD/MTU burnup in the "burned" fuel cells is equivalent to the re-235 activity of the Region 1 checkerboard rack containing 5.0 w/o U

fuel at zero burnup in the "fresh" fuel cells and 2.3 w/o U

fuel at zero bur'nup in the "burned" fuel cells.

It is important to recognize that the curve in Figure 4 on page 21 is based on a constant rack reactivity for that region and not on a

constant fuel assembly reactivity.

In this way, the environment of the storage rack and its influence on assembly reactivity is implicitly considered.

3.3 POSTULATED ACCIDENTS Most accident conditions will not result in an increase in ke<<of the rack. Ex-amples are the loss of cooling systems (reactivity decreases with decreasing water density) and dropping a

fuel assembly on top of the rack (the rack structure pertinent for criticality's not excessively deformed and the dropped fuel assembly has more than twelve inches of water separating it from the active fuel height of stored fuel assemblies which precludes interaction).

However, accidents can be postulated which would increase reactivity (i.e.,

misloading a fuel assembly with a burnup and enrichment combination outside Criticality Analysis of Region 1 Checkerboard Arrangement

I f

of the acceptable area in Figure 4 on page 21, or dropping a

fuel assembly between the rack and pool wall).

For these accident conditions, the double contingency principle of ANSI N16.1-1975 is applied.

This states that one is not required to assume two-unlikely, independent, con'current events to ensure protection against a

criticality accident.

Thus, for accident conditions, the presence of soluble boron in the storage pool water can be assumed as a re-alistic initial condition since not assuming its presence would be a second un-likely event, The presence of approximately 2000 ppm boron in the pool water will decrease reactivity by about 0.25 Dk.

In perspective, this is about five times more negative reactivity than could be added if every cell in the SFP were filled with fresh 5.0 w/o U fuel assemblies.

Thus, for postulated accidents, should there be a reactivity

increase, ki<<would be less than or equal to 0.95 due to the effect of the dissolved boron.

Since the Donald C.'ook Nuclear Plant SFP will be maintained at a boron concentration of 2400 ppm, additional margin will exist to the 0.95 limit.

3.4 SENSITIVITY ANALYSIS To show the dependence of ke<<on fuel and storage cells parameters as re-quested by the NRC, the variation of the ke<<with respect to the following parameters was developed using the PHOENIX computer code:

1.

Fuel enrichment, with a

0.50 w/o U

delta about the pominal case enrichment.

For this sensitivity, both the "fresh" and "burned" fuel as-sembly enrichments were adjusted simultaneously.

2.

Center-to-center spacing of storage cells, with a half inch delta about the nominal case center-to-center spacing.

3.

Poison loading, with a 0.01 gm-B /cm delta about the nominal case poison loading.

Results of the sensitivity analysis for the Region 1 checkerboard storage ar-rangement are shown in Figure 5 on page 22 through Figure 7 on page 24.

Criticality Analysis of Region 1 Checkerboard Arrangement 10

o I'V PP 0

g+

4.0

SUMMARY

OF CRITICALITY RESULTS The acceptance criteria for criticality requires the effective neutron multipli-cation factor, ka<<, to be less than or equal to 0.95, including uncertainties, under all conditions for the storage of fuel assemblies in the Spent Fuel Pool (SFP).

This report shows that the acceptance criteria for criticality is met for the Donald C. Cook Nuclear Plant Spent Fuel Pool (SFP)

Region 1 checkerboard of burned and fresh fuel assemblies.

This conclusion is valid for the storage of Westinghouse 15x15 STD and QFA, and 17x17 STD, QFA and VANTAGE 5, and ANF 15x15 and 17x17 fuel assemblies with the following nominal enrichment limits:

SFP Region 1 "Fresh" Fuel 5.0 wlo U SFP Region 1 "Burned" Fuel 5.0 w/o U, with burnup restrictions given by Figure 4

on page 21 The checkerboard arrangement to be used for the storage of burned and fresh fuel assemblies in the Region 1

area is shown on Figure 2 on page 19.

An example of the interface boundary between the Region 1 checkerboard and the Region 2 area is given by Figure 3 on page 20.

The analytical methods employed herein conform with ANSI N18.2-1973, "Nu-clear Safety Criteria for the Design of Stationary Pressurized Water Reactor Plants," Section 5,7, Fuel Handling System; ANSI 57.2-1983, "Design Objectives for LWR Spent Fuel Storage Facilities at Nuclear Power Stations," Section 6.4.2; ANSI N16,9-1975, "Validation of Calculational Methods for Nuclear Criticality Safety";

and with the NRC Standard Review Plan, Section 9.1.2, "Spent Fuel Storage."

Summary of Criticality Results

h Table 1.

fuel Parameters Employed in Criticality Analysis PARAMETER W STO/OFA W OFA/V5 W STD 15x15 17x17 17x17 ANF 15x15 ANF 17xl7 Number of Fuel Rods per Assembly Rod Zirc-4 Clad O.D, (inch)

Clad Thickness (inch)

Fuel Pei.let O.D.

(inch)

Fuel Pellet Density

(% of Theoretical) 204 0.422 0.0243 0.3659 96 264 0.360 0.0225 0.3088 96 264 0,374 0.0255 0.3225 96 204 0.424 0.0300 0.3565 96 264 0.360 0.0250 0.3030 96 Fuel Pellet Dishing Fac t or

(%)

Rod Pitch (inch)

Number of Guide Tubes Guide Tube O.D.

(inch)

Guide Tube Thickness (inch) 0.0 0,563 20

0. 533
0. 017 0.0 0.496 24
0. 474
0. 016 0.0
0. 496 24
0. 482
0. 016 0.0 0.563 20 0.545 0.017 0.0 0.496 24
0. 480
0. 016 Number of Instrument Tubes Instrument Tube O.D.

(inch)

Instrument Tube Thickness (inch) 0.533

0. 017 0.474 0.016
0. 48-2 0.016 0.545 0.017 0.480
0. 016 12

)

p 4'

l t

E,

Table 2.

Benchmark Critical Experiments [5,6]

General Oescr Ipt ion Snr Icheent v/o U235 Rei'lector SeparatIng liater I a I So lub I ~

Boron pixI Keir 1.

U02 rod 2.

U02 rod 3.

V02 rod 4.

U02 rod 5.

V02 rod 6.

U02 r od 7.

U02 r od 8.

V02 rod 9.

U02 rod 10.

U02 r od 11.

U02 r od 12.

U02 rod 13.

U02 rod 14.

U02 rod 15.

U02 r od 16.

U02 r od 17.

U02 r od 18.

U02 rod 19.

U02 rod 20.

U02 rod 21.

U02 rod 22.

U eetai 23.

U metal 24.

U raetal 25.

U eetal 26.

U aetai 27.

U eetal 28.

U raetai 29.

V rectal 30.

U aeta1 31.

U raetai 32.

U octal 33.

U raetal lattice lett lce lett Ice lett Ice latt Ice lattice latt tce lattice 1 att ice lattice lattice lattice lait lce lett ice 1 at t ice lattice 1 att Ice lattice lattice lattice Iat t Ice cy I inders cylinders cylInders cy1 Inder s cylinders cylinders cylInders cylinders cylinders cyl inder s cy I inder s cy'I Inder s 2.46 2.46 2.46 2.46 2.46 2.46 2.46 2.46 2.46 2.46 2.46 2.46 2.46 2.46 2.46 2.46 2.46 2.46 2 '6 2.46 2.46 93.2 93.2 93.2 93.2 93.2 93.2 93.2 93.2 93.2 93.2 93.2.

93 '

water vater water water wet ~ I water wa ter water wa 't~r water water water water water water vater water water

~ster wa 't~r wat ~r bare bare bare bar ~

bare bar ~

bare parer fln bare par af'f In par aft in para'lr In vater water water 84C pins 84C pins 84C pins 84C pins 84C pins water water stainless steel stainless steel berated aluNInua borated a1unlnue bor ated aluminum bore ted a luxinue borated aluminum borated aluoinun bor aCed aiueinue bor ated aluminum borated a lure inue a Ir air air air air a ir pl ex ig1 ass plexiglass pl exi glass p Iex ig1 ass pl ex ig Iass plexiglass 0

1037 764 00000 0

143 514 217 15 92 395 121 487 197 634 320 72 0

0 0000 0

0 0

0 0

0

+/-

+/-

0.9857 0.9906 0.9896

0. 9914 0.9891 0.9955 0.9889 0.9983
0. 9931 0.9928 0.9967 0.9943

+/'/-

+/>>

+/-

+/-

+/

y/>>

y/>>

+/-

+/>>

+/>>

y/>>

+/-

+/-

+/-

+/-

+/

y/>>

+/-

+/+/-

+/-

+/-

+/-

0.9892 0.9884 0.9832 0.9848 0.9895 0.9885 0.9921 0.9920 0.9939 0.9905 0.9976 0.9947 0.9928 0.9922 0.9950 +/-

0.9941 +/-

0.9928 +/-

0.9968 +/

1.0042 +/-

0.9963 +/-

0.9919 +/

. 0028

. 0018

.0015

.'0025

. 0026

. 0020

. 0027

. 0025

. 0028

. 0025

. 0020

. 0019

. 0023

. 0023

. 0021

. 0024

. 0020

. 0022

. 0019

. 0020

. 0020

. 0020

. 0020

. 0025

.00'19

. 0026

. 0027

. 0030

.0041

. 0018

. 0019

. 0030

. 0032 13

I

Table 3.

Corn parison of PHOENIX Isotopics Predictions to Yankee Core 5

Measurements Quantity (Atom Ratio)

U235/U U236/U U238/U Pu239/U Pu2,40/U Pu241/U Pu242/U Pu239/U238 Mass(Pu/U)

F ISS-PU/TOT-PU

% Difference

-0.67

-0.28

-0.03

~3o27

+3.63

-7.01

,-0.20 3.24

~1.41

-0.02 14

~

~

Table 4.

Benchmark Critical Experiments PHOENIX Comparison Description of Experiments Number of Experiments PHOENIX ketch Using Experiment Sucklings UOt AI clad SS clad Borated H~O Subtotal 14 19 40 0.9947 0.9944 0.9940 0.9944 U-Metal Al clad TOTAL 41 81 1.0012 0.9978 15

Table 5.

pata for IJ Metal and UO$ Critical Experiments (Part l Of 2)

Caae Nuaber Cell Type A/0 H20/U U-2'35 rlatlo Fuel Oenalty (a/CC)

Pellet 01aaeter (CM)

Mater 1 ~ 1 C 1 ad Clad Clad 00 Tlllckneaa (Cli)

(CM)

Lattice P1 tcn (CM)

Bor on PPM 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 38 37 38 39 40 41 42 43 Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Squar e 5quare Squar ~

Square Square Square 5quare Square Square Squar e Square Square Square Square Square Square Square Squar ~

Squar ~

5quar ~

5quare Squar ~

Square Square Square Squar ~

Square Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa

1. 328
1. 328
1. 32d
1. 328
1. 32S
1. 32d
1. 328
1. 328 2.734 2.734 2.734 2.734 2.734 2.734 2.734 2.734 3.745 3.745 3.745 3.745 3.745 3.745 3.745 3.745 4.069 4.069 4.069 2.490 3.037 3.037 4.069 4.069 4.069 4.O69 2.490 2.096 2.096 2.096 2.096 2.096 1.307
1. 307
1. 307 3.02 3.95 4.95 3.92 4.89 2.88 3.58 4.83
2. 18 2.92 3.86 7.02 8.49
10. 3$
2. 50 4.5$

2.50 4.51

4. 51 4.51 4.5$

4.5$

4.51

4. 51 2.55 2.55
2. 14 2.84 2.64
8. 16 2.59 3.53 8.02 9.90 2.84 2.06 3.09 4.12 8.14 8.20 1.01 1.51 2.02 7.53 7.53 7'3 7.52 7.52
10. 53
10. 53
10. 53
10. 1$
10. 18
10. 18
10. 18
10. 18
10. 18
10. 18
10. 18
10. 27
10. 37
10. 37
10. 37

$0.37 10.37

10. 37
10. 37 9.46 9.46 9.46
10. 24 9.28 9.28 9.45 9.45 9.45 9.45
10. 24
10. 38
10. 38

$0. 38

10. 3$
10. 38 18.90
18. 90 lb. 90
1. 5265
1. 5265 1.5265

.9855

.9S55

.9728

.9728

.9728

.7620

.7620

.7620

.7620

.7620

.7620

.7620

.7620

.7544

.7544

.7544

.7544

,7544

.7544

. 7'544

.7544

1. 1278 1.

$ 278

1. 1278 1.0297
1. 1268
1. 1268
1. 1268
1. 1268
1. 1268
1. 1268 1.0297 1.5240 1.5240 1.5240
1. 5240 1.5240
1. 5240
1. 5240
1. 5240 A 1 ua 1 nuh A luh1nua A luh1nua A l uh1 nua A 1 uh1 nuh A luri1nua A luh1 nua A I uri1nua 55-304 55-304 55-304 55-304 55-304 55-304 55-304 55-304 55-304 55-304 55-304 55-304 55-304 55-304 55-304 55-304 55-304 55-304 55-304 A1uh1nuh 55-304 55-304 55-304 55-304 55-304 55-304 Aluh1nua A 1 uh1nua A 1 uh1nuh A lure 1 nuh Aluhlnua A Iuri 1 nua A luri 1 nua Alua lnua Alua1nua
1. 6916
1. 6916
1. 6916 1.

$ 506

1. 1506
1. 1506
1. 1506
1. 1506

". 8594

.$ 594

.8594

.8594

.S594

.8594

.B594

.8594

e600

.8600

eeoo

.$600

.8600

.8600

.8600

.8600 1.2090 1.2090 1.2090

1. 2060
1. 1701
1. 2701
1. 2701
1. 2701
1. 2701 1.270$
1. 2060
1. 6916 1.,69 $ 6
1. 6916
1. 6916
1. 6916
1. 6916 1.6916

. 1.6916

.07110

. 07110

.07110

~ 071 10

.071

$0

.07110

.07110

.07110

.04085

.04085

.04085

.04085

.04085

.04085

.04085

.04085

.04060

.04060

.04060

.04060

.04060

.04060

.04060

.04060

.04060

.04060

.04060

.08130

.07163

.07 163

. 07163

.07163

. 07 163

.07163

. 08130

.07112

.07112

.07112

.07112

.071

$ 2

.07112

.07112

.07112 2 '050 2.3590 2.5120 1

~ 5580

1. 6520

'I. 5580

1. 6520
1. 8060 1.0287
1. 1049
1. 1938
1. 4554
1. 5621 1.6891 1.06 17
1. 2522 1,.06

$ 7

1. 2522
1. 2522

$.2522 1.2522 1.2522 1.2522

1. 2522

$.5113 1.5113

1. 4500 1.5113
1. 5550
2. 1980
1. 5550
1. 6840
2. 1980
2. 3810
1. 5113 2.1737 2.4052
2. 6162
2. 9891 3.3255
2. 1742 2.4054 2.6162 0.0 0.0 0.0 0.0 0.0 0

~ 0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 ~ 0 0,0 0 ~ 0 0.0 0.0 456.0 709.0 1260.0 1334

~ 0 1477.0 0.0 3392.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1677.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 0.

0'6

Table 5.

Data for U Metal and UO> Critical Experiments (part 2 0 f 2)

Case Col )

Nuraber Type Fue)

Pellet A/0 H20/U Density Diameter U-235 Ratio (6/CC)

(CM)

C I act Mater ial OQ Clad (CM)

C I ad Lattice Thickness Pitch Boron (CM)

(CM)

PPM 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 7'3 74 75 76 77 78 79 80 81 Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa Hexa

1. 307
1. 307
t. 160
1. 160
1. 160
1. 160
1. 160 1.040
1. 040 1.040
1. 040
1. 040 1. 307
1. 307
1. 307 1. 307
1. 307
t. f60
1. 160
1. 160
1. 160
t. 160
1. 160
1. 160
1. 160 S. 160
1. 040
1. 040
1. 040 1.040 I. 040 1.040
1. 310
1. 310
1. 159
1. 159 1.312 1.312 3.01
18. 90 4.02
18. 90 1.01 18.90 1.51 18.90 2.02 '8.90 3.01 18.90 4.02 18.90 1.01 18.90 1.51 18.90 2.02 18.90 3.01
18. 90 4.02 18.90 1.00
18. 90 1.52 i8.90 2.02 18.90 3.02 t8.90 4.02 18.90 t.52 18.90 2.02 18.90 3.02 tS.90 4.02 18.90 t.QQ

)$.90 1.52 18.90 2.02 18.90 3.02 18.90 4.02

,18.90 1.33 18.90 1.5S 18.90 1.83 18.90 2.33 18.90 2.83 18.90 3.83 18.90 2.02 18.88 3.01 18.88 2.02 f8.88 3.01 18.88 2.03 18.88 3.02 18.88

1. 5240 1.5240 1.5240
1. 5240 1.5240 1.5240 1.5240 1.5240
1. 5240 1; 5240 1.5240 1.5240

.9830

.9830

.9830

.9830

.9830

.9830

.9830

.9830

.9830

.9830

.9830

.9830

.9830

.9830

19. 050 19.050
19. 050 19.050 19.050 19.05Q
1. 5240
1. 5240
1. 5240 1.5240

'9830

.9830 A I ura I nura A I um I num A I um 1 num A I ura I num A

)urn inurn A

)urn Inurn A I ura 1 rwm A lura I rwm A

turn 1rwra A luminum A I um 1 num A Ium 1 rwra A luminum A I ura 1 num A lum1num A lum inurn A )urn I num A Ium Inurn A I um1num Aluminum A lura inurn A)umtnum A I um 1 num A I um 1 num A I um I num A Iuminum A Iura 1 num Aluminum A Iura inurn A I umi num Alum1num AIura I num A 'Ium1num A I ura 1 num A)umirwm A)um 1 num A lum1rwm A Iumi num

1. 6916
1. 6916
1. 6916
1. 6916
1. 6916
1. 6916
1. 6916 1.6916
1. 6916 1.6916
1. 6916 1.69t6
1. 1506
t. f506
1. 1506

.t. 1506

1. 1506 t506
1. 1506
f. 1506
1. 1506 S. 1506
1. 1506
1. 1506
1. 1506
1. 1506 2.0574 2.0574 2.0574 2.0574 2.0574 2.0574
1. 6916
1. 6916 f.6916
1. 6916 1

~ 1 506

1. 1506

.07112

~ 07112

.07112

.07 112

.07112

.07112

.07112

.OT112

.07112

~ OTS12

~ 07112

.07112

. 07112

.071 12

.07112

.07)12

.07112

~ 07112

.07112

.07112

.071 t2

.07112

.OT 112

.07112

.071 t2

.07 112

.07620

.07620

.07620

.07620

.07620

.07620

.07112

'07 112

.07112

. 07112

.07tt2

.07112 2.9896 3.3249 2

~ 1742 2,4054 2,6162 2.9896 3.3249

2. 1742 2.4054 2.6 I62 2.9896 3.3249
1. 44 12 I. 5926
1. 7247
1. 9609 2 ~ 1742 I

~ 5926

1. 7247 1.9609 2 ~ 1742 1.4412 1.5926
1. 7247 9609 2 ~ 1742 2.8687 3 '086 3.

1425'.3942 3.6284 4 '566 2.6160 2.9900 2 ~ 6160 2 '9900 I. 7250

1. 9610 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Q

Q 0.0 0.0 0.0 17

lf P r

SEE DETAILA 8.884"

0. 196" 1.224" CELL CENIER IO CEMIER (10.5"t

.03" Stainless steel

~.Ot" At 07l" B,C-AI gPRAL

~.ot At 075" Stainless Steel DETAILA INSIDE OF CELL Figure 1.

Oonald C. Cook Nuclear Plant Spent Fuel Pool Storage Cell Nominal Oimensions

IPP

Regi on I

Fr eeh Fuel Region I Burned Fuel Figure 2.

Donald C,Cook Nuclear Plant SFP Region 1 Checkerboard Fuel As-sembly Loading Schematic

t'I

I I

I I

(

I I

Region 1 to 2 Boundary on 1

Region 2 Reg i on l Fr esh Fue 1 Reg 1 on I Burned Fuel Region 2 Bur ned Fuel Figure 3.

Donald C. Cook Nuclear Plant Schematic for SFP interface Boundary Between Regions 1 and 2 20

~

w j's>

I AE

32 30 28 26

~

24 C5 22 20 D

I I

I I

ACCEPTABLE I

I L

I 18 w

16 I

I I

I I

I I

I I

V) o 12 I

1 T

I I

~

10 8

I I

J L

I NOT ACC I

I EPTABLE I

I T

I 2.3 2.5 2.7 2.9 3.1 3.3)5 3.5 3.7 3.9 4.1 4.3 4.5 4.7 4.9 5.1 Uc35 ENRlCHMENT (I/O)

Figure 4.

Donald C.Cook Nuclear Plant SFP Region 1 "Burned" Fuel Assembly Minimum Burnup vs. initial U Enrichment Curve 21

1

~

A I 'gI

'e

'.92

.91

.90 I

I I

.88 I

I I

.87

).55 4.25 1.80 4.50 2.05 '.30 2.55 4.75 5.00 5.25 U

ENRICHMENT (W/0) 2.80 3.05 5.50 5.75 8ORAL HELD AT.02 GM B

/CM CENTER TO CENTER HELD AT 10.50" Figure 5.

Sensitivity of kerf to Enrichment in the Donald C.Cook Nuclear Plant SFP Region 1 Storage Area with Checkerboard Loading 22

.92

.91 I

I I

I I

I I

I

.89

.88 I

I I

I I

I I

I I

I

.8f.80

10. 0 10.2 10.4 10.6 10.8 CENTER-TO-CENTER SPACING (INCHES) 11.0 11.2 BORAL HELD AT.02 GM B

/CM CHECKERBOARD ENRICHMENT HELD AT 2.3/5.0 W/0 Figure 6.

Sensitivity of ke<< to Center-to-Center Spacing in the Donald C.Cook Nuclear Plant SFP Region 1 Storage Area with Checkerboard Loading 23

1 y

'A

.910 905 I

I I-I I

I I

I I

I I

I I

I I

I I-+-

I I

I I

I I

1-I II-

.900 I

I I-I I

I I

I I

I It I

I

+

I II-I II-I I

I 890 I

I I-I I

t-I I-t-I II-I I

t

.885 I

I I

I I

I 880

. 008

. 010

.012

. 014

.016

. 018

. 020

. 022

. 924

. 026 POISON LOAD (GM 8 Iv/CM )

028

.030

.032 CENTER TO CENTER HELD AT 10.50" CHECKERBOARD ENRICHMENT HELD AT 2.3/5.0 W/0 Figure 7.

Sensitivity of kent to B Loading in the Donald C, Cook Nuclear Plant SFP Region 1 Storage Area with Checkerboard Loading 24

4 pV Spy 1l

BIBLIOGRAPHY 1.

W. A. Boyd, et. al., Criticality Analysis of the Donald C. Cook Nuclear Plant, Fuel RacksOctober 1989.

2.

Nuclear Regulatory Commission, Letter to All Power Reactor Licensees, from B. K. Grimes OT Position for Review and Acceptance of Spent Fuel Storage and Handling ApplicationsApril 14, 1978.

3.

W.

E, Ford

- I I I, CSRL-V:

Processed ENOFIB-V 227-Neutron-Group and Pointwise Cross-Section Libraries for Criticality Safety, Reactor and Shielding

Studies, ORNLICSOITM-160, June 1982.

4, N.

M.

Greene, AMPX:

A Modular Code System for Generating Coupled

~

Multigroup Neutron-Gamma Libraries from ENOFIB, ORNL/TM-3706, March 1976.

5, L. M. Petrie and N. F. Cross, KENO IV--An Improved Monte Carlo Criticality

Program, ORNL-4938, November 1975.

6.

M. N. Baldwin, Critical Experiments Supporting Close Proximity Water Storage of Power Reactor Fuel, BAW-1484-7, July 1979.

t 7.

J.

T. Thomas, Critical Three-Dimensional Arrays of U(93.2J Metal Cylinders, Nuclear Science and Engineering, Volume 52, pages 350-359, 1973.

8.

D.

E.

Mueller.

W.

A.

Boyd, and M.

W, Fecteau (Westinghouse NFD), Qualification of KENO Calculations with ENDFIB-V Cross

Sections, American Nuclear Society Transactions, Volume 56, pages 321-323, June 1988.

9.

A. J. Harris, A Description of the Nuclear Design and Analysis Programs for Boiling Water Reactors, WCAP-10106, June 1982.

10.

Askew, J.

R., Fayers, F. J., and Kemshell, P. B., A General Description of the Lattice Code

WINS, Journal of British Nuclear Energy
Society, 5,

pp.

564-584, 1966.

11.

England, T.

R., ClNOER A One-Point Oepleti on and Fission Product

Program, WAPD-TM-334, August 1962.

12.

Melehan, J.

B., Yankee Core Evaluati on Program Final 'eport, WCAP-3017-6094, January 1971.

Bibliography 25

ATTACHMENT 2 TO AEP:NRC:1071N DESCRIPTION OF PROPOSED T/Ss CHANGES AND 10 CFR 50.92 SIGNIFICANT HAZARDS CONSIDERATION ANALYSIS

's r

t E;~

wJ P

~t

Attachment 2 to AEP:NRC:1071N Page 1

Introduction This letter requests, T/Ss changes in the storage pattern in the spent fuel pool.

The changes

'involve Section 5 (Design Section) and are based on criticality and thermal-hydrauli'c concerns.

As discussed later in this attachment,'nalyses have been performed that demonstrate the acceptability of the proposed T/Ss changes with regard to the criticality concerns.

We have also concluded that the current analysis of record for the thermal-hydraulic concerns remains bounding.

Descri tion of Chan es The proposed T/Ss changes are as follows:

1)

In Units 1 and 2 T/S 5.6.1.1, subparagraph c.l has been modified, the existing subparagraph c.2 has been slightly modified and renumbered as c.3, and a new subparagraph c.2 has been added.

2)

Subparagraph c.l identifies "Region 1" of the spent fuel storage racks for storage of Westinghouse fuel types with maximum nominal fuel assembly enrichments of 3.95 weight percent or greater.

Fuel stored in Region 1 must be stored in a checkerboard configuration alternating Westinghouse Category 1 and Category 2 fuel, as shown in Figure 5.6-1 (see Attachment 1, Figure 3).

Category 1

fuel is defined as Westinghouse fuel shown in Figure 5.6-2 as "acceptable for storage as Category 1 fuel."

Category 2 fuel is defined as Westinghouse fuel with an enrichment greater than 3.95 weight percent U-235 and a burnup less than 5,550 MWD/MTU shown on the shaded area of Figure 5.6-2.

These are the maximum enrichments and minimum burnups for Westinghouse fuel that can be stored in Region 2,

as discussed in the next paragraph.

3)

The new subparagraph c.2 identifies "Region 2" of the spent fuel storage racks.

This Region 2 shall be for-the storage of Westinghouse fuel with an enrichment 1ess than or equal to 3.95 weight percent U-235 or with an enrichment greater than 3.95 weight percent U-235 but with a burnup greater than or equal to 5,550 MWD/MTU, and Exxon/ANF fuel of an enrichment less than or equal to 4.23 weight percent U-235 for a 17 x 17 assembly or less than or,equa'1 to 3.50 weight percent U-235 for a 15 x 15 assembly.

The maximum enrichment and minimum burnup limits for Westinghouse fuel that can be stored in Region 2 were justified in our previous submittal AEP:NRC:1071F.

0

Attachment 2 to AEP:NRC:1071N Page 2

4)

The existing subparagraph c.2 is renumbered as c.3 and is being modified slightly to address the boundary condition between Regions 1 and 2.

This boundary condition is that the checkerboard pattern requirement for Region 1 must be carried into Region 2 by at least one row.

This boundary condition is illustrated in the revised figure, Figure 5.6-1.

5)

The second page of Table 5.7-1 in the Unit 2 T/Ss is incorrectly labeled as Table 5.9-1.

This has been revised.

Being purely editorial, this change is not discussed in the significant hazards consideration portion of this attachment.

Summar of Criticalit Anal ses Attachment 1 contains criticality analyses for Region 1 of the spent fuel pool and for the boundary between Regions 1 and 2, prepared for us by Westinghouse.

The analyses were performed in such a way that they bound all types of Westinghouse fuel currently in use or planned for use in the Cook Nuclear Plant.

In accordance with the acceptance criteria of Chapter 9.1.2 (Spent Fuel Storage) of the NRC Standard Review Plan, the Westinghouse analyses demonstrate that the center-to-center spacing between fuel assemblies and any strong, fixed neutron absorbers in the storage, racks are sufficient to maintain the array, when loaded with fuel assemblies with a maximum nominal enrichment of 4.95 weight percent U-235 and flooded with pure water, in a subcritical condition with k ff less than 0.95.

In order to achieve acceptable

results, Westinghouse has determined that fresh fuel assemblies with nominal eff.

enrichments above 3.95 weight percent U-235 must be stored in Region 1 of the spent fuel storage racks in a checkerboard pattern configuration alternating Category 1 and Category 2 fuel.

In addition, this checkerboard pattern of Region 1 must be carried into Region 2 by at least one row.

It should also be pointed out that one fuel assembly, which has an enrichment larger than 4.55 weight percent U-235, would have a k ff larger than 0.95 when out of'he poisoned racks and with 0 ppm of boron in the spent fuel pool.

However, it can be shown that with only 1000 ppm of boron, the k of a fuel assembly with an enrichment of 4.95 weight percent U-235 would be conservatively less eff than 0.95.

The boron concentration in the spent fuel pool is required by T/S 3.9.15 to be greater than 2400 ppm by measurement when fuel assemblies with enrichment greater than 3.95 weight percent U-235 and with burnup less than 5,550 MWD/MTU are in the fuel storage pool.

1 r

4 lg P

Attachment 2 to AEP:NRC:1071N Page 3

Thermal-H draulic Considerations The Cook Nuclear Plant Updated FSAR discusses analyses performed to demonstrate the adequacy of the spent fuel pool cooling system to remove decay heat, and also an, assessment of the time it would take to reach bulk boiling in the event all spent fuel pool cooling is lost.

The most recent analysis of this type was performed by ANF in support of using assemblies capable of 50,000 MWD/MTU exposure.

The analyses were documented in ANF Report No. ANF-88-09.

This analysis was submitted in our letter AEP:NRC:1071 dated August 19,

1988, and supported the Amendments 118 (Unit 3.) and 104 (Unit 2) T/Ss changes.'The analyses were modified slightly as documented in Rev.

1 to ANF-88-09 to correct an error in determining the pool heat load.

The revision resulted in a change in the time to reach bulk boiling from 8.6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> to 5.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />.)

The Unit 2 Vantage 5 assemblies are intended for use up to an average discharge burnup of only 48,000 MWD/MTU.

Also, the Unit 2 power level remains the same at 3411 MWt.

Therefore, spent fuel pool cooling analyses documented in ANF-88-09, Rev.

1, will bound the Vantage 5 assemblies and no new analyses are being submitted.

10 CFR 50.92 Si nificant Hazards Consideration Anal sis Per 10 CFR 50.92, a proposed amendment to an operating license vill not involve a significant hazards consideration if the proposed amendment satisfies the following three criteria:

Does not involve a significant increase in the probability or consequences of an accident previously analyzed, 2)

Does not create the possibility of a new or different kind of accident from any accident previously analyzed or evaluated, or Does not involve a significant reduction in a margin of safety.

Criterion 1

Westinghouse has performed analyses that demonstrate the acceptability of the proposed changes with regard to criticality.

The analyses demonstrate that fuel stored in the spent fuel pool will remain subcritical under design basis conditions.

However, accidents or incidents can take place which would increase reactivity such as dropping a fuel assembly between the rack and pool wall or inadvertently placing a fuel assembly in the wrong location.

For those conditions, the double contingency principle of ANSI N16.1-1975 can be applied.

That principle states that one is

'not required to assume two unlikely, independent, concurrent events to ensure protection against criticality.

Thus, the presence of

A

Attachment 2 to AEP:NRC:1071N Page 4

greater than or equal to 2400 ppm of soluble boron in the spent fuel pool can be assumed as a realistic initial condition, since not assuming it would be a second unlikely event.

The reactivity of the fuel stored in the spent fuel pool would be decreased by about 0.25 delta-k, with approximately 2000 ppm of boron; that is, for an accident or an incident resulting in an increase in reactivity, keff would remain less than or equal to 0.95 due to the effect of the dissolved boron.

In addition, paragraph 2.3 of the SER related to Amendments 118 and 104 for Cook Nuclear Plant Units 1 and 2, respectively, states that "the reactivity reduction due to the required pool boration of 2400 ppm of boron more than offsets the potential reactivity'ncreases from postulated fuel mishandling accidents."

It is concluded that the proposed T/Ss changes should not involve a significant increase in the probability or consequences of a previously analyzed accident.

Criterion 2 The Westinghouse analyses demonstrate continued acceptability of the spent fuel pool regarding criticality.

The T/Ss changes will not result in physical changes to the plant (other than to the fuel assemblies, which were the subject of the Westinghouse analyses).

Therefore, we believe the proposed T/Ss changes will not create the possibility of a new or different kind of accident from any previously evaluated.

Criterion 3

Westinghouse has performed analyses that demonstrate the acceptability of the proposed changes with regard to criticality.

The analyses demonstrate that the fuel stored in the spent fuel pool will remain subcritical under design basis conditions.

However, accidents or incidents can take place which would increase reactivity such as dropping a fuel assembly between the rack and pool wall or inadvertently placing a fuel assembly in the wrong location.

For those conditions, the double contingency principle of ANSI N16.1-1975 can be applied, That principle states that one is not required to assume two unlikely, independent, concurrent events to ensure protection against criticality.

Thus, the presence of greater than or equal to 2400 ppm of soluble boron in the spent fuel pool can be assumed as a realistic initial condition, since not assuming it would be a second unlikely event.

The reactivity of the fuel stored in the spent fuel pool would be decreased by about 0.25 delta-k, with approximately 2000 ppm of boron; that is, for an accident or an incident resulting in an increase in reactivity, keff would remain less than or equal to 0.95 due to the effect of the dissolved boron.

In addition, paragraph 2.3 of the SER related to Amendment 118 and 104 for Cook Nuclear Plant Units 1 and 2, respectively, states that "the reactivity reduction due to the required pool boration of 2400 ppm of boron more than offsets the

e'

~

0

Attachment 2 to AEP:NRC:1071N Page 5

potential reactivity increases from postulated fuel mishandling accidents."

It is concluded that the proposed T/Ss changes should not involve a significant reduction in a margin of safety.

Lastly, we note that the Commission has provided guidance concerning the determination of significant hazards by providing certain examples (48 FR 14870) of amendments considered not likely to involve significant hazards consideration.

The sixth of these examples refers to changes which may result in some increase in the probability of occurrence or in the consequences of a previously analyzed accident, but the results of which are within limits established as acceptable.

The Westinghouse analyses demonstrate acceptable results from a criticality perspective using the acceptance criteria of the NRC Standard Review Plan.

Therefore, we believe the example cited is applicable and that the proposed T/Ss changes do not involve a significant hazards consideration as defined in 10 CFR 50.92.

l

ATTACHMENT 3 TO AEP:NRC:1071N

PROPOSED, REVISED TECHNICAL SPECIFICATIONS PAGES FOR DONALD C.

COOK NUCLEAR PLANT UNITS 1 AND 2

C

DESIGN FEATURES In accordance with the code requirements specified in Section 4.1.6 of FSAR, with allowance for normal degradation pursuant to the applicable Surveillance Requirements, b.

For a pressure of 2485 psig, and c.

For a temperature of 650 F, except for the pressurizer which is 680 F.

VOLUME 5.4.2 The total contained volume of the reactor coolant system is 12,612

+ 100 cubic feet at a nominal T

of 70 F.

avg 5.5 EMERGENCY CORE COOLING SYSTEMS 5.5.1 The emergency core cooling systems are designed and shall be main-tained in accordance with the original design provisions contained in Section 6.2 of the FSAR with allowance for normal degradation pursuant to the applicable Surveillance Requirements.

5.6 FUEL STORAGE CRITICALITY -

SPENT FUEL 5.6.1.1 The spent fuel storage racks are designed and shall be maintained with:

a.

A k f equivalent to less than 0.95 when flooded with unborated eff

water, b.

A nominal 10.5 inch center-to-center distance between fuel assemblies placed in the storage racks.

1.

A separate region within the spent fuel storage racks (defined as Region 1) shall be established for storage of Westinghouse fuel types of enrichments greater than 3.95 weight percent U-235 and burnup less than 5,550 MWD/MTU in a checkerboard pattern configuration alternating Category 1 and Category 2 fuel as shown in Figure 5.6-1.

Westinghouse Category 1 and Category 2 fuel definitions are given in Figure 5.6-2.

COOK NUCLEAR PLANT - UNIT 1 5-5 AMENDMENT NO.

DESIGN FEATURES cont'd 5.6 FUEL STORAGE CRITICALITY -

SPENT FUEL cont'd 2.

A separate region within the spent fuel storage

racks, defined as Region 2, shall be established for storage of Westinghouse fuel of an enrichment less than or equal to 3.95 weight percent U-235 or an enrichment greater than 3.95 weight percent U-235 but with a burnup greater than or equal to 5,550 MWD/MTU, and Exxon/ANF fuel of an enrichment less than or equal to 4.23 weight percent U-235 for a 17 x 17 assembly or less than or equal to 3.50 ~eight percent U-235 for a 15 x 15 assembly.

3.

The boundary between the Regions 1 and 2 mentioned above shall be such that the checkerboard pattern storage requirement of Region 1 shall be carried into Region 2 by at least one row as shown in Figure 5.6-1.

5.6.1.2 Fuel stored in the spent fuel storage racks shall have a maximum nominal fuel assembly enrichment as follows:

Descri tion Maximum Nominal Fuel Assembly Enrichment Wt. I 235 1)

Westinghouse 15 x 15 STD 15 x 15 OFA 4.95 2)

Exxon/ANF 15 x 15 3.50 3)

Westinghouse 17 x 17 STD 17 x 17 OFA 17 x 17 V5 4.95 4)

Exxon/ANF 17 x 17 4.23 CRITICALITY-NEW FUEL 5.6.2.1 The new fuel pit storage racks are designed and shall be maintained with a nominal 21 inch center-to-center distance between new fuel assemblies such that K ff will not exceed 0.98 when fuel, assemblies are placed in the eff pit and aqueous foam moderation is assumed.

COOK NUCLEAR PLANT - UNIT 1 5-6 AMENDMENT NO.

~

~

ct q e

S

DESIGN FEATURES cont'd 5.6.2.2 Fuel stored in the new fuel storage racks shall have a maximum nominal fuel assembly enrichment as follows:

Descri tion Maximum Nominal Fuel Assembly Enrichment Wt.

s 235 1)

Westinghouse 15 x 15 STD 15 x 15 OFA 4.55 2)

Exxon/ANF 15 x 15 3.50 3)

Westinghouse 17 x 17 STD 17 x 17 OFA 17 x 17 V5 4.55 4)

Exxon/ANF 17 x 17 4.23 DRAINAGE 5.6.3 The spent fuel storage pool is designed and shall be maintained to prevent inadvertent draining of the pool below elevation 629'".

CAPACITY 5.6.4 The fuel storage pool is designed and shall be maintained with a storage capacity limited to no more than 2050 fuel assemblies.

5.7 SEISMIC CLASSIFICATION 5.7.1 Those structures, systems and components identified as Category I items in the FSAR shall be designed and maintained to the original design provisions contained in the FSAR with allowance for normal degradation pursuant to the applicant Surveillance Requirements.

5.8 METEOROLOGICAL TOWER LOCATION 5.8.1 The meteorological tower shall be located as shown in Figure 5.1.1.

5.9 COMPONENT CYCLIC OR TRANSIENT LIMIT 5.9.1 The components identified in Table 5.9-1 are designed and shall be maintained within the cyclic or transient limits of Table 5.9-1.

COOK NUCLEAR PLANT - UNIT 1 5-7 AMENDMENT NO.

~

~

0

'l l't j

l

'i

-1 4

)I 4

I I

I I

I i

I

,Region 1 to 2 Boundary l

Re onl Region 2 REGZON 1, CATEGORY 2

FUEL REGZON 1, CATEGORY 1

FUEL REGZON 2

FUEL FIGURE 5.6-l DONALD C.

COOK NUCLEAR PLANT SCHEMATIC FOR SFP INTERFACE BOUNDARY BETWEEN REGIONS I AND 2 COOK NUCLEAR PLANT - UNIT 1 5-8 AMENDMENT NO.

+14 l-

I Region 1 Storage Requirements Burnup vs. 1nitial Enrichment I

Fuel Assembly Burnup (GWD/MTU) 32

,(4.95~ 30.45) 28 24 ACCEPTABLE FOR STORAGE AS CATEGORY 1 FUEL 20-16-12 (3.95, 5.55)

(4.95, 5.55)

REQUIRED TO BE STORED AS CATEGORY 2 FUEL 0

2.2 (2.3, 0.0) 2.6 3.4 3.8

.4.2 4.6 Initial Westinghouse Fuel Enrichment w/o Category 1 - Region above and including line through 2.3 w/o Category 2 - Region in lower right box FIGURE 5.6-2 DONALD C.

COOK NUCLEAR PLANT SFP REGION 1 BURNED FUEL ASSEMBLY MINIMUM.BURNUP VS. INITIALU-235 ENRICHMENT CURVE COOK NUCLEAR PLANT - UNIT 1 5-9 AMENDMENT No.

~

e

TABLE 5.9-1 COMPONENT Reactor Coolant System COMPONENT CYCLIC OR TRANSIENT LIMITS CYCLIC OR TRANSIENT LIMIT 200 heatup cycles at less than or equal to 100 F/hr and 200 cooldown cycles at less than or equal to 100 F/hr (pressurizer cooldown at 0

0 less than or equal to 200 F/hr).

DESIGN CYCLE OR TRANSIENT Heatup cycle

- T from less than or equal to BO F to 0

greater than or equal to 547 F.

Cooldown cycle

- T from ave 0

greater than or equar to 547 F

0 to less than or equal to 200 F.

80 loss of load cycles.

Without immediate turbine or reactor trip.

40 cycles of loss of offsite A.C.

electrical power.

Loss of offsite A.C. electrical power source supplying the onsite Class lE distribution system.

80 cycles of loss of flow in one reactor coolant loop.

Loss of only one reactor coolant pump.

400 reactor trip cycles.

100% to 0% of RATED THERMAL POWER.

200 large step decreases in load.

100% to 5% of RATED THERMAL POWER with steam dump.

COOK NUCLEAR PLANT - UNIT 1 5-10 AMENDMENT NO.

TABLE 5.9-1 COMPONENT COMPONENT CYCLIC OR TRANSIENT LIMITS CYCLIC OR TRANSIENT LIMIT DESIGN CYCLE OR TRANSIENT Reactor Coolant System 1 main reactor coolant pipe break.

Break in a reactor coolant pipe greater than 6 inches equivalent diameter.

Operating Basis Earthquakes 400 cycles

- 20 earthquakes of 20 cycles each.

Secondary System 50 leak tests.

5 hydrostatic pressure tests 1 steam line break Pressurized to 2500 psia Pressurized to 3107 psig.

Break in a steam, line greater than 5.5 inches equivalent diameter.

5 hydrostatic pressure tests Pressurized to 1356 psig.

COOK NUCLEAR PLANT - UNIT 1 5-11 AMENDMENT NO.

'\\

V C

l

VOLUME 5.4.2 The total water and steam volume of the reactor coolant system is 0

12,612

+ 100 cubic feet as a nominal Tavg of 70 F.

5.5 METEOROLOGICAL TOWER LOCATION 5.5.1 The meteorological tower shall be located as shown on Figure 5.1-1.

5.6 FUEL STORAGE CRITICALITY -

SPENT FUEL 5.6.1.1 The spent fuel storage racks are designed and shall be maintained with:

a.

A K equivalent to less than 0.95 when flooded with unborated eff

water, b.

A nominal 10.5-inch center-to-center distance between fuel assemblies, placed in the storage racks.

1.

A separate region within the spent fuel storage racks (defined as Region 1) shall be established for storage of Westinghouse fuel types of enrichment greater than 3.95 weight percent U-235 and burnup less than 5,550 MWD/MTU in a checkerboard pattern configuration alternating Category 1

fuel and Category 2 fuel as shown in Figure 5.6-1.

Westinghouse Category 1 and Category 2 fuel definitions are given in Figure 5.6-2.

2.

A separate region within the spent fuel storage

racks, defined as Regi'on 2, shall be established for storage of Westinghouse fuel of an enrichment less than or equal to 3.95 weight percent U-235 or an enrichment greater than 3.95 weight percent U-235 but with a burnup greater than or equal to 5,550 MWD/MTU, and Exxon/ANF fuel of an enrichment less than or equal to 4.23 weight percent U-235 for a 17 x 17 assembly or less than or equal to 3.50 weight percent U-235 for a 15 x 15 assembly.

3.

The boundary between the Regions 1 and 2 mentioned above shall be such that the checkerboard pattern storage requirement of Region 1 shall be carried into Region 2 by at least one row as shown in Figure 5.6-1.

COOK NUCLEAR PLANT - UNIT 2 5-5 AMENDMENT NO.

5. 6 FUEL STORAGE CRITICALITY -

SPENT FUEL cont'd 5.6.1.2 Fuel stored in the spent fuel storage racks shall have a maximum nominal fuel assembly enrichment as follows:

Descri tion Maximum Nominal Fuel Assembly Enrichment Wt.

8 235 1)

Westinghouse 15 x 15 STD 15 x 15 OFA 4.95 2)

. Exxon/ANF 15 x 15

-,.3. 50 3)

Westinghouse 17 x 17 STD 17 x 17 OFA 17 x 17 V5 4.95 4)

Exxon/ANF 17 x 17 4.23 CRITICALITY -

NEW FUEL 5.6.2.1 The new fuel pit storage racks are designed and shall be maintained with a nominal 21 inch center-to-center distance between new fuel assemblies such that K-'f will not exceed 0.98 when fuel assemblies are placed in eff the pit and aqueous foam moderation is assumed.

5.6.2.2 Fuel stored in the new fuel storage racks shall have a maximum nominal fuel assembly enrichment as follows:

Descri tion Maximum Nominal Fuel Assembly Enrichment Wt.

% 235 1)

Westinghouse 15 x 15 STD 15 x 15 OFA 4.95 2)

Exxon/ANF 15 x 15 3.50 3)

Westinghouse 17 x 17 STD 17 x 17 OFA 17 x 17 V5 4.95 4)

Exxon/ANF 17 x 17 4.23 COOK NUCLEAR PLANT - UNIT 2 5-6 AMENDMENT NO.

1

~

DRAINAGE 5.6.3 The spent fuel storage pool is designed and shall be maintained to prevent inadvertent draining of the pool below elevation 629'4".

CAPACITY 5.6.4 The spent fuel storage pool is designed and shall be maintained with a storage capacity limited to no more than 2050 fuel assemblies.

5.7 COMPONENT CYCLIC OR TRANSIENT LIMIT 5.7.1 The components identified in Table 5.7-1 are designed and shall be maintained within the cyclic or transient limits of Table 5.7-1.

COOK NUCLEAR PLANT - UNIT 2 5-7 AMENDMENT NO.

/

4g fr

,4 I

l I

t l

l

~gfon 1 to? BoQAd~

I Re fon2 REGION 1, CATEGORY 2

FUEL REGION 1, CATEGORY 1

F UEL REGION 2

"UEL FIGURE 5.6-1 DONALD C.

COOK NUCLEAR PLANT SCHEMATIC FOR SFP INTERFACE BOUNDARY BETWEEN REGIONS 1

AND 2 COOK NUCLEAR PLANT - UNIT 2 5-8 AMENDMENT NO.

C I

Region 1 Storage Requirements Burnup vs. Initial Enrichment Fuel Assembly Burnup (GWD/MTU) 32--

(4.95

~ 30.45) 28 24 ACCEPTABLE FOR STORAGE AS CATEGORY 1 FUEL 20 16 12-(3.95

~ 5.55)

(4.95, 5.55) 0 2.2 (2.3 0.0) 2.6 3.4 REQUIRED TO BE STORED AS CATEGORY 2'UEL'.8 4.2 4.6 Initial Wes ting house Fuel Enrichmen t w/o l

I Category 1 - Region above and including line through 2.3 w/o i

Category 2 - Region in lower right box I

FIGURE 5.6-2 DONALD C.

COOK NUCLEAR PLANT SFP REGION 1

BURNED FUEL ASSEMBLY MINIMUM BURNUP VS. INITIALU-235 ENRICHMENT CURVE COOK NUCLEAR PLANT - UNIT 2 5-9 AMENDMENT NO.

TABLE 5.7-1 COMPONENT CYCLIC OR TRANSIENT LIMITS COMPONENT CYCLIC OR TRANSIENT LIMIT DESIGN CYCLE OR TRANSIENT Reactor Coolant System 200 heatup cycles at less than or equal to 100 F/hr and 200 cooldown cycles at less than or equal to 100 F/hr (pressurizer cooldown at 0

0 less than or equal to 200 F/hr).

Heatup cycle

- T from less than or equal to 550 F to 0

greater than or equal to 547 F.

Cooldown cycle

- T from ave 0

greater than or equal to 547 F

0 to less than or equal to 200 F.

80 loss of load cycles.

Without immediate turbine or reactor trip.

40 cycles of loss of offsite A.C.

electrical power.

Loss of offsite A.C. electrical power source supplying the onsite Class 1E distribution system.

80 cycles of loss of flow in one reactor coolant loop.

Loss of only one reactor coolant pump 400 reactor trip cycles.

100% to 0% of RATED THERMAL POWER.

200 large step decreases in load.

100% to 5% of RATED THERMAL POWER with steam dump.

COOK NUCLEAR PLANT - UNIT 2 5-10 AMENDMENT NO.

TABLE 5.7-1 Continued COMPONENT CYCLIC OR TRANSIENT LIMITS COMPONENT Reactor Coolant System CYCLIC OR TRANSIENT LIMIT 1 main reactor coolant pipe break.

DESIGN CYCLE OR TRANSIENT Break in a reactor coolant pipe greater than 6 inches equivalent diameter.

Operating Basis Earthquakes 400 cycles

- 20 earthquakes of 20 cycles each.

Secondary System 50 leak tests.

5 hydrostatic pressure tests 1 steam line break Pressurized to 2500 psia.

Pressurized to 3107 psig.

Break in a steam line greater than 5.5 inches equivalent diameter.

5 hydrostatic pressure tests Pressurized to 1356 psig.

COOK NUCLEAR PLANT - UNIT 2 5-11 AMENDMENT NO.

I