'REGULAT
.. INFORMATION DISTRIBUTION YSTEM (RIDS}
ACCESSION NBR: 8804190403 DOC. DATE: 88/04/11 NOTARIZED:
NO DOCKET FACIL: 50-315,Donald C.
Cook. Nuclear Power Planti Unit ii Indiana 0
050003l5 50-316 Donald C.
Cook Nuc lear Power Plan%i Unit 2i Indiana 5
05000316 AUTH. NAME AUTHOR AFFILIATION GREENMAN, E. G.
Region 3i Ofc of the Director RECIP. NAME RECIPIENT AFFILIATION ALEX ICHOR M. P.
(formerly Indiana
& Michigan Ele N
SUBJECT:
Forwards request for addi info supplementing 8605ibi'1010 5
870528 8: 1110 responses to IE Bulletin 85-003'Motor-Operated Valve Common Mode Failures During Plant Transients Due to Improper Smitch Setting. "
DISTRIBUTION CODE:
IE11D COPIES'ECEIVED: LTR ENCL SIZE:
TITLE: Bulletin Response (50 DKT)
RECIPIENT ID CODE/NAME PD3-3 LA STANGi J INTERNAL: AEOD/DOA AEOD/DSP/TPAB NRR/DEST/ADS 7E NRR/DOEA/EAB 11 NRR/DREP/EPB 10 02 RGN3 F ILE 01 COPIES
=
LTTR ENCL
~
1 0
1, 1
RECIPIENT ID CODE/NAME PD3-3 PD AEOD/DSP NRR/DEST/ADE 8H NRR/DEST/MEB 9H NRR/DOEA/GCB 11 NRR/PMAS/ILRB12 RES/DE/EIB COPIES LTTR ENCL 1
1 1
1 1
1 1
EXTERNAL:
LPDR NSIC 1
1 1
1 NRC PDR TOTAL NUMBER OF COPIES REQUIRED:
LTTR 19 ENCL 18
6P,II IIEGI (4
Np0 ttt tu nO I
~I ttt E
0
+
0 tl'+*at+
UNITED STATES NUCLEAR REGULATORY COMMISSION REGION III 799 ROOSEVELT ROAD GLEN ELLYN, ILLINOIS 60I 97 Docket No. 50-315 Docket No. 50-316 Indiana Michigan Power Company ATTN:
Mr. Milton P. Alexich Vice President Nuclear Operations Division 1 Riverside Plaza
- Columbus, OH 43216 Gentlemen:
Indiana and Michigan Electric Company's letters of May 16 and October 10, 1986, and May 28 and November 10, 1987 pertaining to Cook Units 1 and 2, contained your response to IEB 85-03, "Motor-Operated Valve Common Mode Failures During Plant Transients Due to Improper Switch Settings".
Our review of the responses indicates the need for additional information before the program to assure valve operability can be approved.
The specific information necessary for the completion of our review is enclosed.
Additional information is requested within one month of the date of this letter.
The written report shall be submitted to the Regional Administrator, Region III, under oath or affirmation under provisions of Section 182a, Atomic Energy Act of 1954, as amended.
Also, the original copy of the cover letter and a copy of the report shall be transmitted to the U.S. Nuclear Regulatory Commission Document Control Desk, Mashington, DC 20555 for reproduction and distribution.
guestions addressing this issue may be forwarded to Richard J. Kiessel, NRR (301) 492-1154.
Sincerely,
Enclosure:
Request for Additional Information Edward G. Greenman, Director Division of Reactor Projects See Attached Distribution eeo4i~<<
5ODPSi5 804ii PDR I9IDDCK 0 pDR 8
Indiana and Michigan Electric Co.
Distribution cc w/enclosure:
W.
G. Smith, Jr., Plant Manager pDCD/DCB (RIDS)
Licensing Fee Ma'nagement Branch Resident Inspector, RIII Ronald Callen, Michigan Public Service Commission EIS Coordinator, USEPA Region 5 Office Michigan Department of Public Health R. J. Kiessel, NRR J.
F. Stang, NRR
Pag 1 of 1
MAR 30 1988 REQUEST FOR ADDITIONAL INFORMATION (RAI) RE:
Review of Responses to Action Item e of IE Bulletin 85-03 Licensee:
Indiana 8 Michigan Electric Company P. 0.
Box 16631
- Columbus, Ohio 43216 Unit(s): Cook 1,2 Date of Response:
05-16-86 10-10-86
+05-28-87
+ll-l0-87 Respondent:
M. P. Alexich,
+(Unit 2)
Vice President The information provided in your response to Action Item e of IE Bulletin 85-03 was found to be deficient in some areas.
Provide the additional information necessary to resolve the following comments and questions:
1.
Has water hammer due to valve closure been considered in the determination of pressure differentials?
If not, explain.
- 2. If MOVATS is planned for application to some MOVs which are not included in its data
- base, commit to and describe an alternate method for determining the extra thrust necessary to overcome pressure differentials for these valves.
- 3. Unlisted cold leg injection MOVs IM0-51, -52, -53 and -54 (1 1/2-inch) are normally open downstream of BIT outlet valves ICM'-'250 and -251.
These MOVs are shown in zones E-2, D-'2, C-2 and F-2 respectively
-on drawings 1-5142-24 (Unit 1) and 2-5142-28 (Unit 2).
How would safety injection to 'the cold legs be ensured if these MOVs were to be left closed inadvertently?
Revise Table I of the response of 05-16-86 to include these MOVs, or justify their exclusion.
4.
The proposed program for action items b,
c and d of the bulletin is incomplete.
Provide the following details as a
minimum:
(a) commitment to a training program for setting switches, maintaining valve operators, using signature testing equipment and interpreting signatures, and (b) commitment to justify continued operation of a valve determined to be inoperable.