REGULA Y INFORMATION DISTRIBUTI 1~

SYSTEM (RIDS)

ACCESSION NBR:9906020006 DOC.DATE: 99/05/21 NOTARIZED: YES DOCKET FACIL:50-315 Donald C.

Cook Nuclear Power Plant, Unit 1, Indiana M

05000315 50-316 Donald C.

Cook Nuclear Power Plant, Unit 2, Indiana M

05000316 AUTH.NAME AUTHOR AFFILIATION POWERS,R.P.

Indiana Michigan Power Co.

RECIP.NAME RECIPIENT AFFILIATION Records Management Branch (Document Control Desk)

SUBJECT:

Application for amends to licenses DPR-58

& DPR-74,revising limitations of positive reactivity additions in several TS action statements.

DISTRIBUTION CODE: A001D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: OR Submittal:

General Distribution NOTES:

RECIPIENT ID CODE/NAME LPD3-1 LA STANG, J INTERN

. FILE CENTE

~0~1 R DE/EBB NRR/DSSA/SPLB NRR/SPSB JUNG,I OGC/RP EXTERNAL: NOAC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 1

0 RECIPIENT ID CODE/NAME LPD3-1 PD NRR/DE/EEIB NRR/DE/EMEB NRR/DSSA/SRXB NUDOCS-ABSTRACT NRC PDR COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

0 D

'E NOTE TO ALL NRIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATIONS CONTACT THE DOCUMENT CONTROL DESK (DCD)

ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 14 ENCL 13

I

Indiana Michigan Power Company ~

500 Circle Drive ~

Buchanan, Ml 491071395 IHOIAMA NlCHEGAN PQMfM May 21, 1999 AEP:NRC:1327 Docket Nos.:

50-315 50-316 U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk Mail Stop 0-P1-17 Washington, DC 20555-0001 Donald C.

Cook Nuclear Plant Units 1 and 2

TECHNICAL SPECIFICATIONS CHANGE REQUEST POSITIVE REACTIVITY CHANGES Gentlemen:

Pursuant to 10 CFR 50.90, Indiana Michigan Power Company (I&M),

the Licensee for Donald C.

Cook Nuclear Plant units 1

and 2,

proposes to amend Appendix A, technical specifications (T/S), of facility operating licenses DPR-58 and DPR-74.

I&M proposes to revise limitations on positive reactivity additions in several T/S action statements.

The proposed changes would allow reactor coolant system temperature changes in certain Mode 5 and 6 action statements if the shutdown margin is sufficient to accommodate the'xpected temperature change.

In addition, footnotes regarding additions of water from the refueling water storage tank to the reactor coolant system are clarified and relocated to action statements.

Additional actions are added in Table 3.3-1, "Reactor Trip System Instrumentation,"

when the required source range neutron flux channel is inoperable.

Corresponding changes are proposed for the bases for T/S 3/4.1.1, "Boration Control,"

and T/S 3/4.1.2, "Boration Systems."

Administrative changes are proposed to improve clarity.

Finally, additions are made to shutdown margin T/S surveillance requirements to address use of a boron penalty (requirement for additional boron) during residual heat removal system operation in Modes 4 and 5.

Attachment 1 provides a detailed description and safety analysis to support the proposed changes.

Attachments 2A and 2B provide marked up T/S pages for unit 1

and unit 2,

respectively.

Attachments 3A and 3B provide the proposed T/S pages with the changes incorporated for unit 1

and unit 2,

respectively.

Attachment 4 describes the evaluation performed in accordance with 10 CFR 50.92(c),

which concludes that no significant hazards consideration is involved.

Attachment 5

provides the environmental assessment.

qcy060200 05000315

~ qq05Z1 r

pDR ADO'~

pDR ':

p

U.

S. Nuclear Regulatory Commission Page 2

AEP:NRC:1327 I&M requests approval

'of this request as soon as practicable because unit 1

is in T/S action statements that require suspension of operations involving positive reactivity changes because the emergency diesel generators (EDGs) are inoperable.

This has created a hardship because operations that could affect reactor coolant system temperature need to be performed while maintaining the temperature within a

very narrow range.

The proposed license amendment is needed to provide the flexibility necessary to provide for continued safe reactor operations while also limiting the potential for inadvertent addition of excess positive reactivity.

I&M is expecting the unit 1

EDGs to be operable by June.

However, emerging work on the EDGs and possible emerging work on the emergency buses may prolong the inoperability of the charging pumps
and, thus, the action requiring suspension of operations involving positive reactivity changes.

Two previous submittals affect pages that are submitted in this request.

The T/S pages in attachments 2A, 2B, 3A, and 3B do not reflect the changes proposed in the previous submittals.

I&M will coordinate changes to the pages with the project manager to ensure proper page control when the associated amendment requests are approved.

Copies of this letter and its attachments are being transmitted to the Michigan Public Service Commission and Michigan Department of Public

Health, in accordance with the requirements of 10 CFR 50.91.

U.

S. Nuclear Regulatory Commission Page 3

AEP:NRC:1327 Should you have Mr. David F. Kunsemiller, (616) 466-2405.

any questions, please contact Director of Regulatory

Affairs, at Sincerely, R.

P.

Powers Vice President SWORN TO AND SUBSCRIBED BEFORE ME THlS., 4 /

DAY OF 0

1999 Notary Public

,Mp Commission Expires

~QQ gyp]

Nial JANlCE M. BlCKERS Notaty Pulf< Berrien County, N MyComm',ss on Exnuos Feb. 16, 200t Attachments Cs A. C. Bakken, III, w/attachments J.

E.

Dyer, w/attachments MDEQ DW

& RPD NRC Resident Inspector, w/attachments R. Whale

A ~

~

1 4

/~

I'