ML17325B214

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for Feb 1989 for DC Cook,Unit 2
ML17325B214
Person / Time
Site: Cook 
Issue date: 02/28/1989
From: Giles H, Will Smith
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 8906140104
Download: ML17325B214 (9)


Text

ge CELEBRATED D1SIR1BUTION DEMO.iSTRA,TION SYSTEM REGULATO INFORMATION DISTRIBUTION+STEM (RIDE)

ACCEhSION NBR:8906140104 DOC.DATE: 89/02/28 NOTARIZED:

NO

'OCKET FACIL:50-316 Donald C.

Cook Nuclear Power Plant, Unit 2, Indiana 6

05000316 AUTH.NAME g

AUTHOR AFFILIATION GILES,H.

'ndiana Michigan Power Co. (formerly Indiana a Michigan Ele SMITH,W.G.

Indiana Michigan Power Co. (formerly Indiana a Michigan Ele REClP.NAME RECIPIENT AFFILIATION

SUBJECT:

Monthly operating rept for Feb 1989 for DC Cook, Unit 2.

W/890307 ltr.

DISTRIBUTION CODE:

IE24D COPIES RECEIVED:LTR t

ENCL /

SIZE:

TITLE: Monthly Operating Report (per Tech Specs)

NOTES:

R'ECIPIENT ID CODE/NAME PD3-1 LA STANGFJ INTERNAL: AEOD/DOA IRM TECH ADV NRR/DOEA/EAB 11 NUDOCS-ABSTRACT RGN3 COPIES LTTR ENCL 4

4 1

1 1

1 2

2 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD3-1 PD AEOD/DSP/TPAB NRR/DLPQ/PEB 10 BR/EDREP/PtPB 10 REG FILE Q~

COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 A

D S

EXTERNAL:

EGErG SIMPSONFF NRC PDR 1

1 1

1 LPDR NSIC 1

1 1

1 R

S A

D NVZE TO ALL RIDS" RECIPIEFIS:

PZEASE HELP US TO RKZUCB i6LSTHl CGNI'ACT~ DOCUMEZZ CONTROL DESK KKN Pl-37 (EZZ. 20079)

KO lKZKQCGR YOUR NAME HKH DISTRIBUTXCI LISTS POR DO%MENTS YOU DONIT HEED)

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 20 ENCL 20

Indiana Michigan Power Company Cook Nuciear Plant P.O. Box 458 Bridgran, MI 49106 616 465 5901 U.S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.C.

20555 March 7, 1989 Gentlemen:

Pursuant to the requirements of Donald C.

Cook Nuclear Plant Unit 2 Technical Specification 6.9. 1.10, the attached Monthly Operating Report for the month of February 1989 is submitted.

Sincerely,

~

~

W.

G. Smith, Jr.

Plant Manager WGS/jd CC:

B. A. Svensson NRC Region III D.

R.

Hahn EPRI Nuclear Safety Analysis Center R.

C. Callen S. L. Hall INPO Records Center ANI Nuclear Engineering Department D.

H. Williams, Jr.

M. P. Alexich J.

F.

Kurgan J. J.

Markowsky D. A. Timberlake D.

W. Paul T. 0. Argenta S.

H. Steinhart B. L. Jorgensen J.

R.

Sampson D. S. Climer E. A. Smarrella Dolly Krieger T.

R. Stephens SSOSWOiOS SVG228 PDR ADOCK 050003kb

~NU

t 4

N.R.C OPERATING DATA REPORT DOCKET NO.

50-316 DATE 01-Mar-89 COMPLETED BY H. Giles TELEPHONE 616-465-5901 OPERATING STATUS

1. Unit Name D.

C.

Cook Unit 2

2. Reporting Period FEB 89Inotes 3.

Licensed Thermal Power (MWt) 3411 4.

Name Plate Rating (Gross MWe) 1133

5. Design Electrical Rating (Net MWe) 1100 6.

Maximum Dependable Capacity (GROSS MWe) 1100 7.

Maximum Dependable Capacity (Net MWe) 1060

8. If Changes Occur in Capacity Ratings (Items no.

3 through 7) Since Last Report Give Reasons 9.

Power Level To Which Restricted. If Any (Net MWe) 10.

Reasons For Restrictions. If Any:

11, Hours in Reporting Period 12.

No. of Hrs. Reactor Was Critical

13. Reactor Reserve Shutdown Hours 14.

Hours Generator on Line

15. Unit Reserve Shutdown Hours 16.

Gross Therm.

Energy Gen.

(MWH) 17.

Gross Elect.

Energy Gen.

(MWH) 18'et Elect.

Energy Gen.

(MWH) 19.

Unit. Service Factor

20. Unit Availability Factor
21. Unit Capacity Factor (MDC Net)
22. Unit Capacity Factor (DER Net)
23. Unit Forced Outage Rate 24.

Shutdowns Scheduled over Next Six This Mo.

Yr. to Date 672.0 1416.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0

0 0

0 0

0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Months (Type, Date,and Cumm.

97848 '

63595.1 0.0 62210.0 0.0 189566377 61896220 59584665 65.1 65.1 58.8 57.4 14.5 Duration):

25. If Shut Down At End of Report Period, Estimated Date of Startup:
26. Units in Test, Status (Prior to Commercial Operation):

Forcast INITIALCRITICALITY INITIALELECTRICITY COMMERCIAL OPERATION Achieved

AVERAGE DAILY POWER LEVEL (MWe-Net)

DOCKET NO.

50-316 UNIT TWO DATE 01-Mar-89 COMPLETED BY HE Giles TELEPHONE 616-465-5901 DAY 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 MONTH AVERAGE DAILY POWER LEVEL FEB 89 DAY 17 18 19 20 21 22 23 24 25 26 27 28 AVERAGE DAILY POWER LEVEL

I

~ I UNITSIIIITIHlNNSANOtOlII."llRfllllt'TlONS llwm ~E IloI:gPTNIl 50-316 I:fNtl.ElH)NY mamIONE 61

~ +

~

~

~

14Ie I.henacc I'.ecru kcpua 0 I'auae 4 ('urrectbe Ael4rr ru Preccnl Iteeurreru~

189 880423 cont' S

672 BKC 1

N/A ZZ ZZZZZZ The unit was removed from. service on 880423 for cycle 6-7.

Refueling and steam generator repair project.

The reactor coolant system is cur-rently at rated no load temperature and pressure.

Expected return to service date is late March 1989.

I Iriced S: Lhedided Reaarna:

A I:qulprncnl Failure (Fxl4aln)

IlLIabilcnx~ rrr TeaI l'.Refueling Ilkeyrlatrny Realrldhnl I'.QIeraiur Tralee 4 Ocenae I:xanrinal4rn I'dnrinlalrallae (o (il~rallrrral4rur II!xpQnI II(Nlrer {Iixp4inI 3

Merhud:

I-I4nual 2.manual Saaru.

3 Aulrunarle Seranr.

44lrher {IixpbinI Fxlrlbli6 - Inarrrrelhrra fnl Prcparxl4lo uf I)ala I:nrry Qrccla fur Oeenace Recur kcprrr II.IR}I:ileIHUklG.

OI6I )

IrxhlbllI Salne Suuree

DOCKET NO:

UNIT NAME:

COMPLETED BY:

TELEPHONE:

DATE:

PAGE:

50-316 D.C.

Cook Unit 2 T.

R. Stephens (616) 465-5901 March 7, 1989 1of1 HIGHLIGHTS MONTHLY OPERATING ACTIVITIES -

FEBRUARY 1989 The unit entered the reporting period in Mode 5 with the RCS level at half loop.

For specific details on start up activities see the detail listing below.

The unit ended the reporting period in Mode 4 with the RCS temperature at 339'.

DETAILS 02-02-89 2218 2307 02-09-89 1854 02-13-89 0508 02-16-89 0403 02-19-89 0921 02-22-89 0558 02-24-89 0100 2240 02-26-89 2015 02-28-89 0715 Began fill of the RCS.

Filling of RCS was stopped with Pressurizer level at 39K.

Began Integrated Leakage Rate Test (ILRT) of the containment.

Successfully completed the ILRT.

A RHR System safety valve lifted prematurally resulting in the Pressurizer Relief Tank rupture disc failing discharging approximately 355 gallons of reactor coolant to the containment floor.

RCS fill and vent procedure completed.

Started RCS cooldown in preparation to lower the RCS level to half loop for repairs to a safety injection system check valve due to leakage in excess of tech spec limits.

RCS level at half loop.

Began RCS fill and vent.

RCS fill and vent procedure completed.

RCS entered Mode 4.

4 f, M

t

DOCKET NO.

UNIT NAME DATE COMPLETED BY TELEPHONE PAGE 50-316 D.C.Cook-Unit No.

2 Mare 7,

1989 616 465-5901 1of1 MAJOR SAFETY-RELATED MAINTENANCE FEBRUARY 1989 There were no major safety-related maintenance problems during the month of February.