ML17325A652

From kanterella
Jump to navigation Jump to search
Amend 100 to License DPR-74,approving Steam Generator Repair Program & Providing License Condition Re Repair Program
ML17325A652
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 03/08/1988
From: Virgilio M
Office of Nuclear Reactor Regulation
To:
Shared Package
ML17325A653 List:
References
NUDOCS 8803140362
Download: ML17325A652 (3)


Text

gp,S REgy, (4

tp

~4 0

Cy 4r n

C O

I

.c <

0l 4'y

+W*J +

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. I'. 20555 INDIANA MICHIGAN POWER COMPANY DOCKET NO. 50-316 DONALD C.

COOK NUCLEAR PLANT UNIT NO.

2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.

100 License No.

DPR-74 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Indiana Michigan Power Company (the licensee) dated March 12, 1987, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),

and the Commission's rules and regulations set forth in 10 CFR Chapter I; 8

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

pqR 0~~2 Saaaoa 880szgo p

~DOCK OSooo3>q pQR

ld 4

2.

Accordingly, Paragraph 2.I is added to Facility Operating License No.

DPR-74 to read as follows:

2. I STEAM GENERATOR REPAIR PROGRAM (1)

The licensee is authorized to repair Unit 2 steam generators by replacement of major components.

Repairs shall be conducted in accordance with the licensee's commitments identified in the Commission approved Donald C.

Cook Nuclear Plant Unit No.

2 Steam Generator Repair Report dated November 7, 1986, as revised through Revision 6, and additional commitments identified in the staff s

related Safety Evaluation dated (2)

The Technical Specifications identified in Table 3.2-2 of the Steam Generator Repair Report dated November 7, 1986, as revised through Revision 6 dated February 18, 1988, will not be applicable during the repair program.

For purposes of Technical Specification applicability, the Steam Generator Repair Project will begin when the last fuel assembly from the Unit 2 core is placed in the spent fuel pool and will end when the first fuel assembly is removed from the spent fuel pool to refuel the Unit,2 core.

3.

This license amendment is effective as of the date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION Mart n

. Virgi io, Di ctor Pro'irect ate

-1 D's on of actor ojects - III, IV, V 8

S eci Projects Date of Issuance: 3/8/8S