ML17325A228
| ML17325A228 | |
| Person / Time | |
|---|---|
| Site: | Cook |
| Issue date: | 07/29/1987 |
| From: | Davis A NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Dolan J AMERICAN ELECTRIC POWER SERVICE CORP., INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG |
| References | |
| CAL-RIII-87-12, NUDOCS 8708030170 | |
| Download: ML17325A228 (4) | |
Text
REGUL*TOj.
INFORMATION DISTRIBUTION
. STEM,(RIDS)
ACCESSION NBR:- 8708030170 DOC. DATE: 87/07/29 NOTARIZED:
NO FACIL: 50-315 Donald C.
Cook Nuclear Pacer Planti Unit 1
Indian 50-316 Donald C.
Cook Nuclear Power Plant.
Unit 2i Indian AUTH. NAME AUTHOR AFFILIATION DAVIS'. B.
Region 3i Office of Director RECIP. NAME RECIPIENT AFFILIATION DOLAN'. E.
American Electric Power Service Corp.
DOLAN'. E.
Indiana 8c Michigan Electric Co.
DOCKET a 5 05000315 a
8(
05000316
~
SUBJECT:
Amends 870715 confirmatory action ltribased on 870724 meeting. Corrective action conf irmed re failure rate of 53/
for 870622 requalif ication exams. Facility requalif ication program unsatisfactory.
DISTRIBUTION CODE:
IE01D COPIES RECEIVED: LTR ENCL SIZE:
TITLE."General (50 D'kt)-Insp Rept/Notice of Violation Response NOTES:
RECIPIENT ID CODE/NAME PD3-3 PD INTERNAL:
AEOD NRR MORISSEAUi D NRR/DREF /EPB NRR/DR IS DIR ERM*NiJ G FIL RG
~
ILE 01 COPIES LTTR ENCL REC IP IENT ID CODE/NAME MIGGINGTONi D DEDRO NRR/DOEA DIR NRR/DREP/RPB NRR/PMAS/ILRB OGC/HDSi RES DEPY GI COPIES LTTR ENCL 1
2 1
1 1
EXTERNAL:
LPDR NSIC NRC PDR TOTAL NUMBER OF COPIES REQUIRED:
LTTR 20 ENCL
"ONFIRMATORY ACTION LETTER
/)rag JUL 29 1987 Docket No. 50-315 Docket No. 50-316 American Electric Power Service Corporation Indiana and Michigan Electric Company ATTN:
Mr'. John E. Dolan Vice Chairman Engineering and Construction 1 Riverside Plaza
- Columbus, OH 43216 Gentlemen:
CAL-RIII-87-012 Amendment 1
During the'eek of June 22,
- 1987, NRC requalification exams were administered to licensed operators at the D. C.
Cook plant.
Fifty three percent of the examinees failed.
In accordance with NUREG 1021 regarding requalification program evaluations, it is our determination that the D. C.
Cook requalifica-tion program is unsatisfactory.
You were informed of this by telephone on July 15, 1987.
A Confirmatory Action Letter to you was written to delineate commitments made in this matter on July 15, 1987.
On July 24,
- 1987, a meeting was held between our respective staff members to discuss the examination results and review your plans to implement short and long term corrective actions to the D.
C.
Cook requalification program.
Based on this meeting it is our understanding that you will:
1.
Remove from licensed duties those persons who failed the NRC requalification exams until they successfully complete a
NRC approved accelerated upgrade training program or an NRC examination.
2.
During the evaluation of the annual requalification examination to be administered in August 1987 make an assessment to determine the need for remedial training for all remaining licensed staff personnel in the area of instrumentation and controls.
3.
Provide NRC Region III with the facility exams to be administered in conjunction with Items 1 and 2 in advance for review.
8708030170 870729 PDR ADOCK 05000315 G
PDR CONFIRMATORY ACTION LETTER So/
ONFIRMATORY ACTION LETTER American Electric Power Service Corporation JUL 29 1987 If your understanding of these issues is different from that stated
- above, please inform this office promptly.
Sincerely, cc:
W.
G. Smith,,Jr.,
Plant Manag r DCS/RSB (RIDS)
Licensing Fee Management Branch Resident Inspector, RIII Ronald Callen, Michigan Public Service Commission EIS Coordinator, USEPA Region 5 Office Nuclear Facilities and Environmental Monitoring Section A. Ber Dav s
Regional Administrator R I RIII RI RIII RI RIII ag Burdick/1 c M
1 M!1 lyly Mor gs ii rson P
e iel1 o is ltd
't CONFIRMATORY ACTION LETTER