Text

'j ":.; :,', REGULATLR'YQFDRYiATjDNiDISTR i'juVZDN,SS=-S'(R'iDS)

. il 4l-li

&a4l

'"':I

'll FACIL:50-315 Donald C.

Cook Nuclear Poeer Plant>

Unit ii Indiana 5

05000315 50-316 Donald C.

Cook Nuclear Power Planti Unit 2i Indiana 5

05000316 AUTH. NAME AUTHOR AFFILIATION ALEXICH, M. P.

Indiana 5 Mic hi gan Elec tric Co.

REC IP. NAME RECIP IENl AFFILIATION DENTON> H. R; Office of Nuclear Reactor Regulationi Director (post 851125 S UHJECT: Application for amends to Licenses DPR-58 8c DPR-74i authorizing extension of 72 h time limit for loop inoperability when essential svc eater pump out of svc for replacement or repair. Fee. paid.

DISTRIBUTION CODE:

A001D COPIES RECEIVED: LTR ENCL SIZE:

TITLE:

OR Submittal:

General Distribution NOTES:

OL: 10/25/74 OL: 12/23/72 05000315 05QOQ316 RECIPIENT'D CODE/NAME PWR-A ADTS PWR-A EB PWR-A FOB PWR-A PSH IATERNAL:

ACRS 09 ELD/HDS3 BRO/RRAH EG FIL 04 COPIES LTTR ENCL 1

0 1

1 1

1 1

1 6

6 1

0 1

1 1

RECIPIENT ID CODE/NAME PWR-* PD4 PD 01 PWR-A EICBB WIGGINGTONi D PWR-A RSH ADM/LFMB NRR/DHFT/TSCH NRR/ORAS RGN3 COPIES LTTR ENCL 5

5 1

1 1

1 1

1 1

0 1

1 1

0 1

1 EXTERNAL: 24X LPDR NSIC 03 05 1

1 2

2 1

1 EGhG HRUBKEi S NRC PDR 02 1

1 1

1 TOTAL NUMBER OF COPIEB REQUIRED:

LTTR 31 ENCL 27

l('MIXR)5:.

'P hGLTVGZRTP.LH MOiiTAi""iJ-, !')

'!'AA~Vc.'-l!i

'lr ill I

Ii 1

p' F

"I t.,a h

l II V'I!

4 ll Vt A J

'I I Qtt g

'I, 4 Pft III J

'$ <<," C Qd't((

.J V

~'

t ii

'((

ii E

<<~( t I

, ti

~I CPS"< 4 I (',!,

.<<PP 1

VI f

'I g t 1

Gi ll

,r,

~

'P I '",,"~y.

E'j A

"<<1 f

E-J 1

1

~

, ii l<

A. "g g'E't l ~ I, I ~ 1-V L 1 ( t') = INDIANA8 MICHIGAN ELECTRIC COMPANY P,O, BOX 16631 COLUMBUS, OHIO 43216 January 17, 1986 AEP:NRC:0972 Donald C. Cook Nuclear Plant Unit Nos. 1 and 2 Docket Nos. 50-315 and 50-316 License Nos. DPR-58 and DPR-74 TECHNICAL SPECIFICATION CHANGE REQUEST: ESSENTIAL SERVICE WATER PUMP INOPERABILITY TIME LIMIT Mr. Harold R. Denton Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555

Dear Mr. Denton:

This letter and its attachments constitute an application for amendment to the Technical Specifications for the Donald C. Cook Nuclear Plant Unit Nos.

1 and 2.

We request that this application be expedited to avoid the possibility of an unwarranted unit shutdown.

Specifically, we are requesting that the 72-hour limit for loop inoperability be extended when an Essential Service Water (ESW) pump is out of service for repair or replacement.

As a compensatory

measure, we are proposing an additional change to require the other three ESW pumps to be operable (one pump from the affected unit and the other two from the opposite unit with the ESW system aligned in the cross-tie mode).

This change is being requested for both units.

For reasons described

below, we may require this change in order to allow Unit 1 to continue operation at power.

We are requesting an identical change for Unit 2 for consistency between units.

In-service testing data for the Unit 1 West ESW pump has indicated gradual degradation in the pump's performance.

Data taken on December 23, 1985 indicated degradation to the point where pump replacement may be required in the near future and prior to any scheduled cold shutdown outage.

We would prefer to begin this replacement by the end of February 1986, to ensure that the pump does not fall below minimum performance standards.

In the last five years, four Unit 1 ESW pump replacements have been performed, of which one was in a mode in which the ESW pumps were required to be operable.

On that occasion the necessary work was accomplished in 60 hours6.944444e-4 days <br />0.0167 hours <br />9.920635e-5 weeks <br />2.283e-5 months <br />, which is within the 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> allowed by the Action Statement of Technical Specification 3.7.4.1.

However, repair times twice as long have ggagg20482

~~0~0~7s15 PDR ADOCg, 05DOpDR p

QIP )

i)~gigfi&4~

I ~

l, r

C, r

'I C

Mr. Harold R. Dent AEP:NRC:0972 been experienced when complications have arisen.

In all cases where pump repair or replacement is required, we will proceed with diligence to return the pump to operable status as rapidly as possible and within the presently allowed 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

Based on experience,

however, we feel that it is necessary to request this change in order to avoid the possibility of a unit shutdown.

Our analysis concerning significant hazards considerations is contained in Attachment 1 to this letter.

The proposed Technical Specification pages are contained in Attachment 2.

We believe that the proposed changes will not result in (1) a significant change in the types of effluents or a significant increase in the amounts of any effluent that may be released offsite, or (2) a significant increase in individual or cumulative occupational radiation exposure.

These proposed changes have been reviewed by the Plant Nuclear Safety Review Committee (PNSRC) and will be reviewed by the Nuclear Safety and Design Review Committee (NSDRC) at their next regularly scheduled meeting.

In compliance with the requirements of 10 CFR 50.91(b)(1),

copies of this letter and its attachments have been transmitted to Mr.'. C. Callen of the Michigan Public Service Commission and Mr. G. Bruchmann of the Michigan Department of Public Health.

Pursuant to 10 CFR 170.12(c),

we have enclosed an application fee of $150.00 for the proposed amendments.

This document has been prepared following Corporate procedures which incorporate a reasonable set of controls to insure its accuracy and completeness prior to signature by the undersigned.

Very truly yours,,

M. P. Alexi Vice President [)I~~~

Attachments cc:

John E. Dolan W. G. Smith, Jr. Bridgman R. C. Callen G. Bruchmann G. Charnoff NRC Resident Inspector Bridgman

P) f

'Py'g, VV 'Il y -fy

~

11 J

~

I il y,

)

g J

IL Jpw r vip )

~

Jl r ~ p r

r I II jf

]

I I

J J

Pf~

I 4

h J,

~

P y

r r V)

ATTACHMENT 1 TO AEP:NRC:0972 REASONS AND 10 CFR 50.92 ANALYSES FOR CHANGES TO THE DONALD C.

COOK NUCLEAR PLANT UNIT NOS.

1 AND 2 TECHNICAL SPECIFiCATIONS

Attachment 1

Technical Specification 3.7.4.1 requires that at least two independent essential service water (ESW) loops be operable in Modes 1

through 4.

The action associated with only one independent loop operable allows 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> to restore the other loop to operable status.

In order to perform routine maintenance necessary because of normal pump degradation, it is necessary to voluntarily remove one ESW pump from service.

To ensure that maintenance is thoroughly performed, it may be necessary to take more time than the 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> allowed.

Thus, we are requesting to add a footnote to pages 3/4 7-17 (Unit 1) and 3/4 7-13 (Unit 2).

The footnote will allow continued power operation provided that three ESW pumps are operable and remain available to either of the Cook units.

The Bases section (page B 3/4 7-4 for both units) has been revised to reflect this change.

As described in Section 9.8 of the Updated FSAR, the ESW system contains four pumps that are shared between the units via cross-tie valves.

The ESW system supplies cooling water from Lake Michigan for the component cooling heat exchangers, containment spray heat exchangers, emergency diesel generators, and the control room air conditioning units.

Additionally, the ESW system provides a backup water source for the auxiliary feedwater

pumps, should the condensate storage tank be unavailable or empty.

As seen in Table 9.8-5 of the Updated FSAR, only two of the four ESW pumps are necessary for design-basis conditions with both units at power.

We have also stated in the Updated FSAR that we have the capability to provide sufficient ESW water to service a

LOCA in one unit while the other unit is undergoing cooldown.

The latter case requires three pumps to remove the heat load, and is outside the plant design basis.

(This is because the design basis of Cook establishes hot shutdown as the safe condition.)

Nevertheless, we will require three pumps to be operable to ensure we maintain the capability for unit cooldown beyond the 'hot shutdown condition.

Even though these changes may result in an increase in the probability of occurrence or consequences of a previously analyzed

accident, the results ar'e clearly within acceptable limits as established in the D. C.

Cook FSAR.

We thus believe these changes do not involve a significant hazards consideration as defined in 10 CFR 50.92.

In addition, an editorial change has been made on one of the affected pages.

In Unit 2, page B 3/4 7-4, the word "emergency" has been changed to lower case to reflect the fact that it is not a defined term.