ML17321A921

From kanterella
Jump to navigation Jump to search
NPDES Noncompliance Notification:Blowdown Sample Taken on 851001 from Heating Boiler Contained Iron Concentration of 1.48 Ppm Due to Chemical Shock
ML17321A921
Person / Time
Site: Cook  
Issue date: 10/03/1985
From: Menge R
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: Zugger P
MICHIGAN, STATE OF
References
NUDOCS 8510220067
Download: ML17321A921 (2)


Text

sWeen INDIANA5 MICHIGANEIECTRIC CDMPANV ONE SUMMITSOUARE. P.O. BOX 60, FORT WAYNE. IN, 46801 TeIephene (219) 425-2111 October 3, 1985 ICHARD C. IIIEPGE Vice President Paul D. Zugger, Executive Secretary Michigan Water Resources Commission Stevens D. Mason Building, Box 30026 Lansing, Michigan 48909

Dear Mr. Zugger:

RE:

D. C.

Cook Nuclear.Plant NPDES Permit No. MI 0005827 Heating Boiler Blowdown A blowdown sample taken October 1,

1985 from the heating boiler which was placed in use on July 16, 1985 after a considerable period of inactivity, was found to contain an iron concentration of 1.48 PPM.

Since chemical treatment of this boiler is made by blotch addition, we believe the iron level in the blowd'own is due to chemical shock.

By copy of this letter, the Nuclear Regulatory Commission is notified pursuant to the requirements of Appendix B, Part II, Nonradiological, Environmental Protection Plan,.Section 3.2.

Very truly yours, Richard C. Menge Vice President RCM/df c:

J G. Keppler NRC, Region III W. G. Smith, Jr.

I certify under penalty of law that I have personally examined and am familiar with the information submitted on this and all attached documents; and based on my inquiry of those individuals immediately responsible for obtaining the information, I believe the submitted information is true, accurate and complete.

I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment.

~C.

Richard C. Menge 8510220067 851003 PDR; ADOCK '050003i 5 8 '.

PDR

c:

M. P. Alexich. Columbus H. B. Brugger Columbus J.

E. Dolan Columbus R.

W. Jurgensen Columbus R. F. Kroeger Columbus K. D. Mack Columbus R.

W. Reeves/C.

E.

Hawk Columbus A. A. Blind Cook Plant T. A. Kriesel Cook Plant NRC Resident Inspector Cook Plant PNSRC Cook Plant J.

F. Stietzel Cook Plant G. Charnoff, Esq.--

Shaw, Pittman, Potts

& Trowbridge R.

E. Zahler, Esq.

Shaw, Pittman, Potts

& Trowbridge R. C. Callen Michigan Public Service Commission D.

R.

Hahn Michigan Department of Public Health H. R. Denton Nuclear Reactor Regulations ~

Dottie Sherman ANI Library INFO Records Center