Text

Docket No: 50-315

50-316

MAY 7

'l985

American Electric Power Service

Corporation

Indiana

and Michigan Electric Company

ATTN:

Mr. John

E.

Dolan

Vice Chairman

Engineering

and Construction

1 Riverside Plaza

Columbus,

Ohio

43216

Gentlemen:

This is in response

to your letter AEP:NRC:0499A dated

March 25,

1985,

concerning your verbal

commitment to perform a periodic visua1 inspection

of the containment

pape tunnel

sump in regard to IE Bulletin 80-24.

I

. Followup verification of your actions to implement IE Bulletin 80-24 was

performed by the Senior Resident Inspector at the D.C.

Cook plant site and

documented in Inspection

Reports

85010/85010(DRP) for Units 1 and 2,

respectively.

Based

upon verification of the availability and reliability

of installed equipment,

termination of the visual inspections

is considered

acceptable.

This letter confirms, approval to discontinue the referenced

inspections,

notification of which was previously provided to you verbally through the

Senior Resident

Inspector

on May 3, 1985.

Sincerely,

cc:

M.

G. Smith, Jr., Plant Manager

DMB/Document Control Desk (RIDS)

Resident Inspector, RIII

Ronald Callen, Michigan

Public Service

Commission.

EIS Coordinator,

USEPA

Region

5 Office

Nuclear Facilities and

Environmental Monitoring

Section

J. J. Harrison, Jr.

(DRS)

RIII

RIII

Suermann/kja

p'r1ght~

05/03/85

~/~F+<

8505100139

850507

PDR

ADOCK 050003i5,

G

PDR

C.

E. Norelius, Director

Division of Reactor Projects

Sae

dp

V

d

,1