~yzpp INDIANA & MICHIGAN ELECTRIC COMPANY DONALDC. COOK NUCLEAR PLANT P.O. Box 468, Bridgman, Michigan 49106 (616) 465-6901 April 5, 1984 p pgQ 'QP Mr. J.G. Keppler, Regional Administrator United States Nuclear Regulatory Commission Region III 799 Roosevelt

'Road Glen Ellyn, IL 60137 Operating License DPR-58/74 Docket Nos. 50-315/50-316

Dear Mr. Keppler:

Pursuant to the requirements of Appendix B, Part II, Nonradiological', Environmental Protection Plan, Section 3.2, a

copy of the report to the Michigan Water Resources Commission notifying them of a high iron concentration in the Backup Heating Boiler Blowdown on February 24 and March 13, 1984, is attached.

This report is required by Amendment No.

54 to Facility Operating License No.

DPR-58 and Amendment No.

40 to Facility Operating License No. DPR-74 dated May 6, 1982.

Sincerely, W.G.

Smx

, Jr.

Plant Manager

/bab Attachment cc:

John E. Dolan M.P. Alexich R.F. Kroeger H. Brugger E.R.

Swanson, RO:III R.C. Callen, MPSC G. Charnoff, Esq.

J.M. Hennigan H.R. Denton, NRC R.O. Bruggee, EPRI E.L. Townley J.F. Stietzel INPO Dir., IE Dir., MIPC PNSRC 8P0g1'q032h 840405 PDR 'ADOCK 05000315 8

PDR.

)

Ar J

l l

l l

4i'

+ merteen INDIANAEt NICHIGANEIECTRIC CDNPANY ONE SUMMITSQUARE, P. O. BOX 60, FORT WAYNE IN. 46801 Telephone: (219) 42S-2'111 March 23, 1984 Mr. Paul D. 7.ugger Executive Secretary Michigan IVater Resources Commission Stevens T. Mason Building Box 30026 Lansing, Michigan 48909 r,

4 ~

RICHARD C. hIEPfGE Vice President Re:

Donald C. Cook Nuclear Plant NPDES Permit No. Ml 0005827 Boiler Blowdown

Dear Mr. Zugger:

A back-up heating boiler which had not been in use for approximately three years was started up for test purposes.

A blowdown sample taken February 24, 19&4, was analyzed and found to have an iron concentration of 1.37 PPM.

On March 13, 1984, after minor repairs had been

made, the boiler was again started.

A blowdown sample was analyzed and found to contain 6.7 PPM iron.

ln both instances, the iron levels probably result from such infrequent use and occasional start-up.

An NPDES modification which exempts the plant heating boilers from iron and copper limits was approved at a meeting of the Michigan Water Resources Commission on March 21, 1'979, although the staff has never formally modified the permit to reflect this administrative action.

Very truly yours, R. C.

Men Vice President P,CM/he cc:

W. G. Smith I certify under penalty of Iaw that I have personally examined and am familiar with the informa<<on submitted in this and all attached documents; and based on my inquiry of those individuals immediately responsible for obtaining the information, I believe the submitted information is true, accurate and complete.

I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment.

Wc.

R. C. Menge

0 qC;~