~ q$ % RICE C~ 0 n

.a UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 INDIANA AND MICHIGAN ELECTRIC COMPANY DOCKET NO. 50-315 DONALD C.'COOK NUCLEAR PLANT UNIT NO.

1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 73 License No.

DPR-58 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

B.

C.

D.

E.

The application for amendment by Indiana and Michigan Electric Company (the licensee) dated February 28, 1983, complies with the standards"and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set'orth in 10 CFR Chapter I; The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

( 8305170080 830504

'PDR'DOCK 050003l5 P

PDR

2 ~

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No.

DPR-58 is hereby amended to read as follows:

(2)

Technical S ecification 1I t

The Technical Specifications contained in Appendices A and 8, as revised through Amendment No. 73, are hereby incorporated in the license.

The licensee shall operate the facility in accordance

.with the Technical Specifications.

3.

In addition, paragraph 2.C.(5)'of Facility Operating License Ho.

DPR-58 is hereby amended to read as follows:

"S ent Fuel Pool Stora e

The licensee is authorized to store D.

C.

Cook, Unit 1

and Unit 2 fuel assemblies, new or irradiated in any combination, up to a

total of 2050 fuel assemblies in the shared spent fuel pool at the Donald C.

Cook -Nuclear Plant subject to the following conditions:

Fuel stored in the spent fuel pool shall not have an enrichme'nt greater than 4.00K Uranium-235 or a fissile fuel density greater than 50.5 grams of Uranium-235 per axial centimeter of fuel assembly or the reactivity equivalent thereof."

4.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION teven A. Yarga, Ch Operating Reactors Division of Licensing h Ho.

1

Attachment:

Changes to the Technical Specifications Date of Issuance:

May 4, 1983

cW~ R~C+c

<<*i~+

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555

~

~

INDIANA AND MICHIGAN ELECTRIC COMPANY DOCKET NO. 50-316 DONALD C.

COOK NUCLEAR PLANT UNIT NO.

2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.

55 License No.

DPR-74 1.

The Nuclear Regulatory Commission (the Comission) has found that:

A.

B.

C.

D.

The application for amendmerIt by Indiana and Michigan Electric Company (the licensee) dated February 28, 1983, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the CoIImIission; There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment.is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the li'cense is amended by changes to the Technical Specifications-as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No.

DPR-74 is hereby amended to read as follows:

(2)

Technical S ecification The Technical Specifications contained in Appendices A and 8, as revised through Amendment No.

55, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

In addition, paragraph 2.C.(3)(5) of Facility Operating License No.

DPR-74 is hereby amended to read as follows:

"S ent Fuel Pool Stora e

The licensee is authorized to store D.

C. Cook, Unit 1

and Unit 2 fuel assemblies, new or irradiated in any combination, up to a total of 2050 fuel assemblies in ihe shared spent fuel pool at the Donald C.

Cook Nuclear Plant subject to the following conditions:

Fuel stored in the spent fuel pool shall not have an enrichment greater than 4.005 Uranium-235 or a fissile fuel density greater than 50.5 grams of Uranium-235 per axial centimeter'f fuel assembly or the reactivity equivalent thereof."

4.

This license amendment is effective as of the date of its issuance.

FO THE NUCLEAR REGULATORY COHNISSION even

. Varga, Ch e

Operating Reactors nch No.

1 Division of Licensing

Attachment:

Changes to the Technical Specifications 1

Date of Issuance:

pay 4, 1g83.

ATTACHMENT TO LICENSE AMENDMENTS Af1Ef)DHEHT HO.

TO FA'CILITY OPERATING LICENSE NO.

DPR-58 AHENDMEHT HO.

TO FACILITY OPERATING LICENSE NO.

DPR-74 DOCKET HOS. 50-315 AND 50-316 Revise Appendix A as follows:

~RP Unit 1

5 3*

5-4 5-5 Insert Pa es 5 3*

5-4 5-5 Unit 2 5-5 5-5

  • For convenience only.

0 44)lq' I ~

.V J); /.V/

$/ \\

,;('l/

~

~ 0

! r.

~ $ / If

/

/t C/.

/iz' Y

.I I

L N

I 33

~

\\

~,M o

4

$t)

I)

C

~

~

I 0

~

HIVdv)

~

~%)V~V

\\

~

It) ~

~

)

~ t 0

)) $

st Q I

i:

t

)

p ~

)

It p,

~

I ~

~ I

~

~ ~

$ $:>O)I t

~

t) e

$ $tI

$ $)

e

~ 'blvd

~I I n)V)fMrn

$) ~

P

)$ $ ~

II A

~ '.

)/

. J

).1

/+

$ )5 ~ ~)

~ ~

4

~

~

~

/,

'"~ t)t I

4p/(

~i/

~

~ I pi I

+/

>/'

Lil'inP$$On

/t p

g~ ggn I

i /

CIICIIII)d j/

rt I; ct~

r'"

'C

~

/

~

~

.."I.

~".,

~ +~a~ r.'r 'i

'I "

d.8

() ~

~

. ]7

'I ~l I

DONALD C.COOK NUCLEAR PLANT LOW POP ULATlON ZONE F'lG 5 1-2 D.

C. CQGY,-Utiii 1

5-3 Amendment'o'.

73 ---

DESIGN FEATURES DESIGN PRESSURE AND TEYiPERATURE 5.2.2 The reactor containment building is desi gned and shall be main-tained in accordance with the original design provisions contained in Sec ion 5,2.2 of the FSAR.

P ENETP ATIOiNS 5.2.3 Pene.rations throuch the reactor containmeni building are desioned 2nd sha1 li be mair ta-'nec in accorda nce with the original desi on provisions contained in Section 5.4 of the FSAP, with allowance

-,or normal de-gradation pursuan to the applicable Surveillance Requtrements.

3 REACTOR. CORE FUEL ASSEMBLIES 5.3.1 The re ctor core sl all contain 193 fuel assemblies with'ach

,uel assembly containing 204 fu 1 rods clad witn Zircoloy -4.

Each fuel rod shall have

=

nominal active fuel leng.h o, 144 inches and con.ain a maximum total weight of 2236 grams uranium.

The initial core loading shall have a maximum enrichment of 3.35 weight percent U-235.

Reload fuel shall be similar in physical design to the initial core loading and shall h'ave a maximum enrichment o

4 O weight percent U-235.

CONTROL ROD ASSEYiBLIES 5.3,2 The reactor core shall contain 53 control rod assemblies.

The full.length

'ontain a nominal 142 inches of absorber of absorber material shall be 80 percent percent cadmium.

All control rods shall tubing.

full lenoth and no part length control rod assemblies shall material.

The nominal values

silver, 15 percent indium and 5

be clad with stainless steel 5.4 REACTOR COOLANT SYSTEYi DESIGN PRESSURE AND TEfiPERATURE 5'.4.l The reactor coolant system is designed and shall be maintained:

{.'. C.

COOK-UNIT 1

5-4 Amehdmen Ho. 73

d I

I II I

I i II

~ ~

v

~

a is p 1 0 d4 ss

~ v ~

0d4 r ccor"ance with;he code require.".enits s-eci;iad in Section

.1.5 ne FS~R, with allowance =or nc.,.a', deoradat on pursuant to the icabl e Sur vei H ance Requ r~~ents,

a. "ressure o.,

2425 psig, and a =e.-..perature o= 550bF, except

-,or.

he pressurizer which is

~

~

>'I Lail 5.4. 2

.io I ~ dv I

1CO c""ic 0Q ds ds /i0 (Iisi/

LI ~ ~ i(vvdlC I contained volume o= the reactor coolant sys-am is 12,6'2

'"e t at a nominal Tav of 7CoF.

CORE COOL!iiG SYST""NS I

~

~

~

I I 0 ~

0

~

v The ="..er",ency core'ooling systems are des gned and shall be main-ta;neo;r.

ac-ordance with;he or i"inai des;cn.irovlgions contained in Sec=ior.

6.2 o-,

the FSAR with ailowanc ror jior..al degradation pursuart t" the applicable Surveillance Reouire. ents.

I l

j v ~

I I

vvv 0 I v iJ Sisv 0d

~

S

~ ~

\\ dv vi ~ vi

.I

~

~ J v'v V ~ V ~ 0 ~ 0

~

4 Th

. s-en=

-,uel st"rage racks are designed ard shall be maintained wl h

~ I I I a.

4 k

== euival nt t" less

-..". n G.g" when;lcoded with urborated Wat NIs r inai lO " inch center-t"-cente.

Cis ance between

,Jet ass=;.bi'es piac d in the s.or "e racks.

~ 0 ~

s 0 ~ ie I

-.;el st"r d in the spen-as s ~"..'" 1 v enri chmen".

uel s
"race racks shall;",ave a nominal as Iollows:

I'lax'mum Hciiilnai Fuel

.<<sseIIbij Enr chmegt i >>0 0 0' IS ~

~

~ I

~ i0

~

s idi I ~

v I Ig

~

~ I/0 e

~ Vv

'0

!Il Y

I ~0~ ~

wd Iist

~ I

~

0

~(08 Oesc. lotion Res inghouse 1,5 x '5 Exxon 15x 15

'/iestinghouse 17 x 17 Exxon 17 x i7 Mestinghouse OFA 15 x 15 3.50 3.50 F 50 3.84 4.00 Ili C

i vsQ

~ C I

I I

~ I I

The new,uel nit st"race racks ar e designed and shall be

~ith

~ n=."..inai 2l inch center-to-center distance

.etween asse.".."lies such ha=

Y -;-; will not exceed G.":8 when

.="ei

., lV 8 V (as defined in Section 5.6.1.2) are placed pit ard acue us

'oam moderation is ass";.,ed.

"aintained

~lew."elt

./oes;,

in the lt D,

C. C"ok'- Unit 1

0vvv

~amendment

.'(o.

73

>>ni i<<v i(~

j>>

V

~

V ~

Thee t "el

'<<va e.

aiid 5

earn Yo lUi Ie 0

~

2,6
2

=

'.QO cubic =ee.

as a romi..a1

"" "-""-"'""-'-C'L 0"=8 LOCr ii"'1 the ree c.or coclan".

Svs-.em is T,

of 70of.

Avg

~ ri ~

I ~t!--

li D<> ko=f e)U wa:er, ivalen" to less

-han G.P"- when f1 "odec wi-h unborat b.

4 r,c." r,a; assembl'ies 0.=" inch c nter-""-=e.".-er ";s-.anc

'-e=,Ye A -,'

plac d in ".he s:orace racks.

'i

~ r ~ v ~ r I

~ 2

."el I ~ ee ilax im<<.UHl i(c <<iAal Fuel nssemo1$

h I

~ lr y

v

<<J

<<1 V ~

J Res

.- e..<< e" st"red:A "he spent

-Uei s".orage racks shail have a

ncm',Aai assembi'J e~ricbm n: as folios s:

Il

~ <<

~ lIi e I I

I I

II i'trtr<<

I I,VIt I

~

rt Ig ve>>'

I I

r r r

~

~

rrr Vii&I ~

I'>>

'Res-. inghous e

xxon Mes inghouse

<<xxon Westinghouse X

~

~

X i l7 x '7 X ri7 15 x 15 dtvO 3.50 3.50 V ~ hr<<

4. 00

<<I S'

tr i Ae eg, e i l

5 "r g racks ar "es cried rd s "a Ac'i a i 2w inch center-to-center d

s "aAc be assai C1 I as Sucn tie'e<<f, Wiil'iot exce d 0 P5 wAeA U

i i ~ -', lV 8 V (as defined in. Section.5.6.1.2) are'placed and aqueous

-oam mccera ion is assume~.

<<tr t

I<<IC I ~ ~ Irth

~

~ ~

<<<<<<CIII(>>ie i i'!Pes 4 )

3'n the pit D.

C, Cook - Uni'.

2

~rencmen:

.'lo.

55