ML17319B569

From kanterella
Jump to navigation Jump to search
Amend 62 to License DPR-58,extending Until 821009, Permissible Operation in Modes 2 & 3 W/One Safety Injection Pump Inoperable
ML17319B569
Person / Time
Site: Cook 
(DPR-58-A-062, DPR-58-A-62)
Issue date: 09/17/1982
From: Varga S
Office of Nuclear Reactor Regulation
To:
Shared Package
ML17319B570 List:
References
NUDOCS 8210120560
Download: ML17319B569 (4)


Text

~R.IllQy 4

PO

<v O

0

%'**<<~

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 INDIANA AND MICHIGAN ELECTRIC COMPANY DOCKET NO. 50-315 DONALD C.

COOK NUCLEAR PLANT UNIT NO.

1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.

62 License No.

DPR-58 1.

The A.

B.

C.

D.

E.

Nuclear Regulatory Commission (the Commission) has found that:

The application for amendment by Indiana and Michigan Electric Company (the licensee) dated September 17, 1982, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and The issuance of this amendment is in accordance with 10 CFR Part 51 of the COIImission's regulations and all applicable requirements have been satisfied.

8210i20560 8209f7 PDR ADOCK 05000815 PDR

'2.

Accordingly, the license is amended by extending the date from seven days to October 9, 1982, for permissible operation for one Safety Injection Pump inoperable that was approved by Amendment No.

58 to Facility Operating License No.

DPR-58 dated September 9, 1982.

3.

This license amendment is effective as of the date of its issuance.

FO THE NUCLEAR EGULATORY COMMISSION

Attachment:

Changes to the Technical Specifications Date of Issuance:

September 17, 1982 ven

. Var a ate g,C1 f Operating Reactors nch No.

1 Division of Licensing

ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO.

62 TO FACILITY OPERATING'LICENSE NO.

DPR-58 DOCKET NO. 50-31'5 Revise Appendix A as follows:

Remove Pa e

3/4 5-3 3/4 5-3

EMERGENCY CORE COOLING SYSTEMS ECCS SUBSYSTEMS - T

> 350'F LIMITING CONDITION FOR OPERATION 3.5.2 Two independent ECCS subsystems shall be OPERABLE with each subsystem comprised of:

a.

One OPERABLE centrifugal charging

pump, b.

One OPERABLE safety injection pump+

c.

One OPERABLE residual heat remova1 heat exchanger, d.

One OPERABLE residual heat removal

pump, and An OPERABLE flow path capable of taking suction from the refueling water storage tank on a safety injection signal and transferring suction to the containment sump during the recir-culation phase of operation.

APPLICABILITY:

MODES 1, 2 and 3.

ACTION:

a.

Pith one ECCS subsystem inoperable, restore the inoperable sub-system to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

b.

In the event the ECCS is actuated and injects water into the Reactor Coolant System, a Spezial Report shall be prepared and submitted.to the Comnission pursuant to Specification 6.9.2 within 90 days describing the circumstances of the actuation and the total accumulated actuation cycles to date.'Only one safety injection pump is required to be operable in Modes 2 and 3 for a period of time thr u October 9, 1982.

Afte~. October 9, 1982, this exemption to the r equir ements of the Technical Specifica-tions and this note no longer apply...

D.C.COOK-UNIT 1 3/4 5-3 Amendment No.

>4