ll I

l V

1

~p,g Rfqy (4

fp0

>+c 0

+***>>

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 INDIANA AND MICHIGAN ELECTRIC COMPANY DOCKET NO.

50<<315 DONALD C.

COOK NUCLEAR PLANT UNIT NO.

1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No, 58 License No.

DPR-58 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

B.

C.

D.

E.

The application for amendment by Indiana and Michigan Electric Company (the licensee) dated September 7, 1982, complies with the standards and requirements of the Atomic Endrgy Act of

1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

8209280553 820909 PDR ADOCK 05000315 PDR K'

S I

~

~,

~

, ~:'* ~

~. ~:.Jz.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C. (2) of Facility Operating License No. DPR-58 is hereby amended to read as follows:

(2)

Techni cal S eci ficat i ons The Technical Specifications contained in Appendices A and 8, as revised through Amendment No. 58, are hereby Incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

Attachment:

Changes to the Technical Specifications Date of Issuance:

September 9,

1982 Steven A. Varga, Chief Operating Reactors Br anch 4 1 Division of Licensing

~ ~

ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO. 58,.TO FACILITY'OPERATING LICENSE'NO: DPR-58 DOCKET NO-. 50-315 Revise Appendix A as fol1ows:

Remove Pa e

3/4 5-3 Insert Pa e

3/4 5-3

~

~

EMERGENCY CORE COOLING SYSTEMS ECCS SUBSYSTEMS - T 5 350'F LIMITING CONDITION FOR OPERATION 3.5.2 Two independent ECCS subsystems shall be OPERABLE with each subsystem comprised of:

a.

One OPERABLE centrifugal charging

pump, b.

One OPERABLE safety injection pump,"

c.

One OPERABLE residual heat removal heat exchanger, d.

One OPERABLE residual heat removal

pump, and e.

An OPERABLE flow path capable of taking suction from the refueling water storage tank on a safety injection signal and transferring suction to the containment sump during the recir'-

culation phase of operation.

APPLICABILITY:

MODES 1, 2 and 3.

ACTION:

a.

b.

With one ECCS subsystem inoperable, restore the inoperable sub-system to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

In the event the ECCS is actuated and injects water into the Reactor Coolant System, a Special Report shall be prepared and submitted to the Comnission pursuant to Specification 6.9.2 within 90 days describing the circumstances of the actuation and the total accumulated actuation cycles to date.

  • Only one safety injection pump is qequired to be operable in Modes 2 and 3 for a period of time not to exceed 7 days beginning when.

the Unit enters Mode 3 during startup from the 1982 refueling outage.

This note consti'tutes a one time exemption to the requirements of the Technica1 Specification.

0.C. COOK-'UNIT 1 3/4 5-3 Amendment No.

M