Text
Docket Nos. 50-315 50-316 JUL 27. 1982 Mr. John Dolan, Vice President Indiana and Michigan Electric Company Post Office Box 18 Bowling Green Station New York, New York 10004
Dear Mr. Dolan:
SUBJECT:
COMPLETION OF TMI ACTION ITEM II.E.4.2.7 Distribution:
Docket File NRC PDR Local PDR ORB ¹1 Rdg DEisenhut OELD OI&E (1)
RCilimberg EReeves MFiel ds SVarga CParrish NSIC ACRS (10)
JHeltemes We have completed our review of your AEP:NRC:0642 December 7, 1981, clarification of your previous submfttals on the Donald C.
Cook Nuclear Plant Units 1 and 2 Radiation monitoring system.
You stated that "the three containment radiatfon monitoring channels R-2, R-ll and R-12 auto-matically initiated closure of all 14 containment purge supply and exhaust isolation valves."
We conclude that this information combined with our safety evaluation report enclosed with my letter of October 30, 1981, is acceptable for completion of action on Item II.E.4.2 Position 7 (purge and vent valves closing on high radiation fn primary containment).
We are still expecting your request for changes to the technical specifi-cations related to this action.
Sincerely, cc:
See next )age ORIGINE'IGHED Steven A. Varga, Chief Operating Reactors Branch
¹1 Division of Licensing 8208050014 820727 PDR ADOCK 05000315 p
PDR OFFICE/
SURNAME$
DATE0 DL:ORP¹g s EARe%es 7////82 DL:ORB RCilim rg:
7//5/82 7/23(82
)
8 SA arga 7/$0/82 NRC FORM 318 (10-80) NRCM 0240 OFFIClAL RECORD COPY USGPO: 1981~39-960
/
/
"s s
~
a 4
~
I h
~
~
e k
Mr. John Dolan Indiana and Michigan E 1 ec tr ic Company cc:
Mr. Robert W. Jurgensen Chief Nuclear Engineer American Electric Power Service Corporation 2 Broadway New York, New York 10004 Gerald Charnoff, Esquire
- Shaw, Pittman, Potts and Trowbridge 1800 M Street, N.W.
Washington, D. C.
20036 Maude Preston Palenske Memorial Library 500 Market Street St. Joseph, Michigan 49085 W.
G. Smith, Jr., Plant Manager Donald C. Cook Nuclear Plant P. 0.
Box 458 Bridgman, Michigan 49106 U. S. Nuclear Regulatory Commission Resident Inspectors Office 7700 Red Arrow Highway Stevensville, Michigan 49127 William J. Scanlon, Esquire 2034 Pauline Boulevard Ann Arbor, Michigan 48103 The Honorable Tom Corcoran United States House of Representatives Washington, D. C.
20515 James G. Keppler Regional Administrator - Region III U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137
l lg
.4