PMP EPP INDEX INDIANA 5 MICHIGAN PO'iiER COMPANY
- DONALD C.
COOK NUCLEAR PLAf'lT PLANT MANAGER PROCEDURE fndev Identification Number Titie Revisior, No.t And Oate Ccvzen ts PMP 2081 EPP.001 Emergency Telephone Communi ca tions EPP.002 Barring of the PABX EPP.003 follow-Up Off-Site Communications EPP.004 Protective Action Guides (PAGs) and Protective Actions EPP.005 Personnel Evacuation
- Rev, 1
6-24-82 Revision 1
6-29-82 Revision 0
4-1-81 Revision 0
4-1-81 Revision 1
5-25-82 TP-1,4-30-82 Exp NA EPP.006 Activation of the Reentry and Rescue Team Revision 0
4-1-81
'PP.007 EPP.008 Securi ty Actions Ouring Emergency Conditions
/
Emergency Medical Plan Guidel i nes
- Revision, 1
5-5-82 Revision 0
4-1-81 EPP.009 Health Physics Procedures EPP,010 Activation of Radiation Monitoring Teams EPP.011 On-Site Radiological Monitoring EPP.012 Off-Site Radiological Monitoring EPP.013 Environmental Monitoring and Analysis Revision 0
4-1-81 Revision 0
4-1-81 Revision 0
4-1-81 Revision 0
4-1-81 Revision 0
4-1-81 TP-1,2-25-82 Exp N/A TP-1,2-25-82 Exp N/A 82072f008f 8207f8 PDR ADOCK.OS00031 S' PDR.
Pace Rev.
I I
IIIIDIAIIIA8 /MICHIGAN E'LECTRIC COMPANY DONALD C. COOK NUCLEAR PLANT PROCEDURE COVER SHEET Procedure No. P~P 2081 EPP PP2 Revision No.
BARRING OF THE PABX SCOPE OF REVISION Rev.
1:
Update all sections of the procedure.
SIGNATURES ORIGINAL REV. 2 PREPARED BY QUALITYASSURANCE REVIEW INTERFACING DEPARTMENT HEAD CONCURRENCE DEPARTMENT HEAD APPROVAL PLANT NUCLEAR SAFETY COMMITTEE PLANT MANAGER APPROVAL N.A.
N.A:
~ v, r gd.dr or DATE OF ISSUE
'")
3-31-81 Fcaa No. PN 20101-axv.p
~
~
e 208l EPP.002 LIST GF EEHXTIVE PETS PM% NUMBER l
2 REVISICN NUMBER AND DAXZ Rev. l, June 29, 1982 Rev. l, June 29, 1982 Page l of l Rev. ], 6-29-82
2081 EPP.002 INDIANA & MICHIGAN EEZCZRIC CCMPMY DONALD C.
CCXJK NUCLEAR PLANT BARRY% OF THE PABX l.0 OBJECTIVES pxocedure lists the steps required to modify the PABX (Mid-iMchigan)
.Telep?one system to eliminate direct ccmnunications between in-plant and off-site telephones.
Once barred, ccnrnunications between on-site and off-site Mid iMchigan telephones must go through the telephone operator.
- 2. 0 RESPONSIBZLZTIZS The Technical Superintendent is responsible for assuring the barring of the PABX when directed by the Cn-Site Emexger~ Ccordinator.
- 3. 0 INSTRUCPIONS 3.1 Proceed to the PABX Bxm at El. 622'f the Administration Building.
3.2 Obtain the key to the doors of the Digital Telephone Systan, Inc.
PABX cabinet fran Accounting Office key box, TSC or fran the s~
drawer of the file cabinet in the north-western corner of the PABX Rocm.
3.3 Unlock and open the door in the left, half of the PABX cabinet.
CM7ZXON:
DO NVZ KOCH CIRCUIT CARDS WZTH HANDLES MAXED ZN RED.
K)RK CNLY WITH CARDS NUi4RRED 764101 OR 764109.
ASSJRE PROPER GKX3NDING FOR SAPPY.
3.4 Pxoceedirg one circuit card at a time, perform the following steps on each card not marked in red in shelves One through Three.
3.4.1 Grasp the top and bottcm handles azd pull outward about four inches until you see the light blue class of sexvice switches on the right front portion of the card.
KliE: THERE ARE 8 LIGHT EKl3E CLASS OF SERViCE SWIKZKS ON EACH CIRCUIT CARD.
ALSO'ACH OF 'IHE 8 SERVICE SWZKZKS ERS 8 POSITICN SWZXCHFS.
3.4.2 Proceeding one service switch at a time, use a percil or pen and throw the first four position switches (top 4 of the 8) to 'the positions indicated:
3rd pull ~towazd u
gull ~tcward u
Page 1 of 2 Rev. 1-6 2982
+gL I
~
2081 EPP.002 CAUTICN:
CO hCT ALTER POSITICNS OP POSITICN SWITCHES 5 THFQUGH 8.
3.4.3 When all 8 light blue class switches on one card have had their top 4 position switches placed in the final position, push the circuit card back into the cabinet and lock both upper and lower handles.
3.5 When all circuit cards in the left half of the cabinet have been barred, close the door, lcck it, unlock the right door, and perform the func-tions in step 3.4 on the circuit cards not marked in red (those numbered 764101 or 764109) iud%:
ALL PABX EXZENSICNS ARE MM BAIRD FBCH 02%UNICAT32G DIBECZLY WITH OVZSIDE KK~CHICAN~SICNS.
3.6 Close and lock the door of the right cabinet and return the key to the place it was obtained fran (see step 3.2).
Page 2 of 2 Rev. 1, 6-29'-82