Primary Coolant Sys Pressure Isolation Valves,Dc Cook Units 1 & 2, Technnical Evaluation Rept
ML17319A819
Person / Time
Site: Cook  
Issue date: 10/24/1980
From: Noell P, Stilwell T
FRANKLIN INSTITUTE
To: Polk P
Office of Nuclear Reactor Regulation
Shared Package
ML17319A817 List:
References
CON-NRC-03-79-118, CON-NRC-3-79-118 TER-C5257-256, TER-C5257-256-257, NUDOCS 8105040072
Download: ML17319A819 (11)


Text

ATTACHt<ENT TECHNICAL EVALUATIONREPORT PRifviARYCOOLAiiTS r STEiVi PRESSURE iSOLATiON VALVES INDIANA R MICHIGAN ELECTRIC COMPANY D.

C, COOK UNITS 1 AvD 2 NRC DOCKET NO.

50 315 50 316 NRC TAC NO.

12923, 12924 NRC CONTRACT NO. NRC43-79-118 FRC PROJECT C5257 FROTASK 256, 257 Prepared by Franklin Research Center The Parkway at Twentieth Street Philadelphia, PA 19103 Author: P.

N. Noell T.

C. Stilwell FRC Group Leader:

P.

N. jpoel].

Prepared for Nuclear Regulatory Commission Washington, D.C. 20555 Lead NRCEngineer:

P. J. Polk October 24, 1980 This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, or any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for any third party's use, or the results of such

use, of any information, apparatus, product or process disclosed in this report, or represents that its use by such thirg party would not infringe privately owned rights.

Illl Franklin Research Center A Division of The Franklin institute The Benjamin Frankrin Parkway, Phih., Pa. 19103 (215) 448-1000 810.s04607+

~

~

V

1.0 KHTRODUCTlOH The HRC has deter ned that cert"in isol "tion valve configurations in systems connecting the high-pressure Primary Coolant System (PCS) to lower-pressure systems extending outside containment are potentially significant contributors to an intersystem loss-of-coolant accident (LOCA).

Such configu-rations have been found to represent a significant factor in the risk computed for core melt accidents.

The sequence of events leading to the core melt is initiated by the con-current failure of two in-series check valves to function as a pressure isola-tion barrier between the high-pressure PCS and a lower-pressure system extend-ing beyond containment.

This failure can cause an overpressurization and rup-ture of the low-pressure system, resulting in a LOCA that bypasses containment.

The HRC has determined that the probability of failure of these check valves as a pressure isolation barrier can be significantly reduced if the pressure at each valve is continuously monitored, or if each valve is periodi-cally inspected by leakage testing, ultrasonic examination, or radiographic inspection.

The NRC has established a program to provide increased assurance that such multiple isolation barriers are in place'in all operating Light Water Reactor plants designated by DOR Generic 1mplementation Activity B-45.

In a generic letter of February 23,

1980, the NRC requested all licensees to identify the following valve configurations which may exist in any of their plant systems communicating with the PCS:
1) two check valves in series or 2) two check valves in series with a motor-operated valve (MOV).

For plants in which valve configurations of concern are found to exist, licensees were further requested to indicate:

1) whether, to ensure integrity of the various pressure isolation check valves, continuous surveillance or periodic testing was currently being conducted,
2) whether any check valves of concern were known to lack integrity, and 3) whether plant procedures should be revised or plant modifications be made to increase reliability.

Franklin Research Center (FRC) was requested by the NRC to provide tech-nical assistance to NRC's B"45 activity by reviewing each licensee's submittal

against criteria provided by the HRC and by verifying the licensee's reported findings from plant syste= drawings.

'h report documents FRC s technical review.

2.0 CRITERIA 2.1 Identification Criteria For a piping sys tem to have z valve configuration of conce~,

the follow-ing five items must be fulfilled:

1) The high-pressure system must be connected to the Primary Coolant System;
2) there must be a high-pressure/low-pressure interface present in the line;
3) this same piping must eventually lead outside containment;
4) the line must have one of the valve configurations shown in Figure 1;

and

5) the pipe line must have a diameter greater than 1 inch.

pcs ov 0

QOV cv HP LP Figure 1.

Valve Configurations Designated by the NRC To Be Included in This Technical Evaluation

2 '

Periods,c Testing Criteria For licensees whose plants have valve conrigurations oi concern and cnoose to institute periodic valve leakage testing, the HRC nas established criteria for frequency of testing, test conditions, and acceptable leakage rates.

These criteria may be summarized as follows:

2.2.1 Frequency of Testing Periodic hydrostatic leakage testing>>

on each check valve shall be accom-plished every time the plant is placed in the cold shutdown condition for refueling, each time the plant is placed in a cold shutdown condition for 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> if testing has not been accomplished in the preceding 9 months, each time any check valve may have moved from the fully closed position (i.e.,

any time the differen-tial pressure across the valve is less than 100 psig),

and prior to returning the valve to service after maintenance, repair, or replacement work is performed.

2. 2. 2 Hydro s ta tic Pres sure Criter ia Leakage tests involving pressure differentials lower than function pres-sure differentials are permitted in tnose types of valves in which service pressure will tend to diminish the overall leakage channel
opening, as by pressing the disk into or onto the seat with greater force.

Gate valves, check valves, and globe-type valves, having function pressure differential applied over the seat, are examples of valve applications satisfying this requirement.

When leakage tests are'ade in such cases using pressures lower.than function maximum pressure differential, the observed leakage shall be adjusted to function maximum pressure differential value.

This adjustment shall be made by calculation appropriate to the test media and the ratio between test and function pressure differential, assuming leak-age to be directly proportional to the pressure differential to the one-half power.

2.2.3 Acceptable Leakage Rates:

~

Leakage rates less than or equal to 1.0 gpm are considered accept-able.

o Leakage rates greater than 1.0 gpm but less than or equal to 5.0 - ~

gpm are considered acceptable if the latest measured rate has not exceeded the rate determined by the previous test by an amount

  • To satisfy ALARA requirements,,leakige may, be measured indirectly (as from the perf'ormance of pressure indicat'ors) if accomplished in accordance with approved procedures and supported by computati'ons showing that the method is capable of demonstrating valve compliance with the leakage criteria.

that reduces the margin between ihe measured leakage ate and the maximum permissible rate of 5.0 gpm by 50% or greater.

~

Leakage rates greater than 1.0 gpm but less than or equal to 5 '

gpm are considered unacceptable if the latest measured rate ex-ceeded the rate determined by the previous test by an amount that reduces the margin between measured leakage rate and the maximum permissible rate of 5.0 gpm by 50% or greater.

e Leakage rates greater than 5.0 gpm are considered unacceptable.

3.0 TECHNICAL EVALUATION

3.1 Licensee's

Response

to the Generic Letter In response to the NRC's generic letter [Ref. 1], the Indiana

& Michigan Electric Company (IME) stated

[Ref. 2] that, "We have reviewed the systems that use check valves to perform a pressure isolation function within the Class 1

boundary of the high pressure isolation function within the piping to low-pressure piping that could potentially allow a LOCA to bypass the containment and found that neither of the valve configurations described in Mr. Eisenhut's letter exist at Cook Plant."

Since no valve configurations of concern were described by the licensee, no valve performance surveillance techniques were mentioned.

Nevertheless, a

valve configuration of concern was discovered'in the Low-Head Safety Injection System by FRC.

It is FRC's understanding that, with IME's concurrence, the NRC will direct IME to change its Plant Technical Specifications as necessary to ensure that periodic leakage testing (or equivalent testing) is conducted in accor-dance with the criteria of Section 2.2.

3.2 FRC Review of Licensee's

Response

FRC has reviewed the licensee's response against the plant-specific Piping and Instrumentation Diagrams (P&IDs) [Ref. 3] that might have the valve con-figurations.of concern.

FRC has also reviewed the'fficacy of instituting periodic testing for the cneck valves involved in this particular application with respect to the re>>

duction of the probability of an intersystem LOCA in the Low-Head Safety In-jection System pipe lines.

In its review of the P&IDs (Ref. 3] for Donald C. Cook Units 1 and 2, FRC found the following piping system to be of concern:

The valve configuration of concern for D. C.

Cook Units 1 and 2

exist in the Low-Head Safety Injection System cold leg branches leading to the PCS Loops 2 and 3.

These cold leg branches contain a

dual check valve in-series configuration with both branches joining to a common-motor-operated valve (MOV).

'The high-pressure/low-pressure interface exists on the upstream side of the single MOV.

The valves comprising the configuration of concern are itemized below for D. C.

Cook Units 1 and 2.

Low-Head Safety injection System Loop 2. cold leg high-pressure check valve, SI-170L2 high-pressure check valve, RH133 high-pressure MOV, ICM111, normally closed (n.c.)

Loo 3, cold le high-pressure check valve, SI-170L3 high-pressure check valve, RH134 high-pressure MOV, ICMlll, n.c.

In accordance with the criteria of Section 2.0, FRC found no other valve configurations of concern existing in this plant.

FRC reviewed the effectiveness of instituting periodic leakage testing of the check valves in these lines as a means of reducing the probability of an intersystem LOCA occurring.

FRC found that introducing a program of check valve leakage testing in accordance with the criteria summarized in Section 2.0 will be an effective measure in substantially reducing the probability of an intersystem LOCA occurring in these lines, and a means of increasing the probability that these lines will be able to perform their safety-related functions., It. is also a step toward achieving a corresponding reduction in the plant probability of an intersystem LOCA in Donald C. Cook Units 1 and 2.

l gU

4.0 CONCLUSIOiN Based on the previously docketed information and drawings made available for FRC review, FRC found that the cold-leg branches

<or PCS loops 2 and 3 of the Low-head Safety Injection System in D. C. Cook Units 1 and 2 contain a

valve configuration of concern (identified in Figure 1).

Thus, if the licens-ee's review of the valving configuration contained in the cold-leg branches of the Low-Head Safety lniection System confirms FRC's finding, then the valve configurations of concern existing in D. C. Cook'Units 1 and 2 incorporate the valves listed in Table 1.0.

Ef IME modifies the Plant Technical Specifications for Donald C.

Cook Units 1 and 2 to incorporate periodic testing (as delineated in Section 2.2) fo the check valves itemized in Table 1.0, then FRC considers this an acceptable means of achieving plant compliance with the NRC staff objectives of Reference l.

Table 1.0 Primary Coolant System Pressure Isolation Valves Svstem Check Valve No.

Allowable Leakage~

Low-Head Safety Injection Loop 2, cold leg Units 1 and 2

SI-170L2 RH133 Loop 3, cold leg SI-170L3 RH134 Wo be provided by the licensee at a future date in accordance with Section 2.2.3.

5.0 REFERENCES

1.

Generic NRC letter, dated 2/23/80, from Mr. D. G. Fisenhut, Department of Operating Reactors (DOR), to Mr. J.

E. Dolan, Indiana

& Michigan Electric Company (IME).

'indiana

& Michig"~ 'cctric Cc-...""""'s response t" ".',RC's letter, d" cd 3/24/80, from Hr. J.

E. Dolan (INE) to Mr. D. G. Eisenhut (DOR).

3.

I.ist of e-amined P&ZDs:

American Electric Power Service Corporation Drawings of Donald C.

Cook Units 1 and 2:

1-2-5115A-21 1-2-5128-8, Sh.

1 of 2

1-2-5128A-16, Sh.

2 of 2

1-2-5129-15, Sh.

1 of 2 1-2-5129A-13, Sh.

2 of 2

1-2-5131-12 1-2-5141-12, Sh.

1 of 3 1-2-5141A-16, Sh.

2 of 3

1-2-5141B-10, Sh.

3 of 3 1-2-5142-16 1-2-5143-20