Monthly Operating Rept for Jul 1980
ML17319A543
Person / Time
Site: Cook 
Issue date: 08/04/1980
From: Gillett B
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
Shared Package
ML17319A542 List:
References
NUDOCS 8008180550
Download: ML17319A543 (8)


Text

ee

. ~

OPe<<TLXC DaTA Re~ORT DOCK:-TiO.

DAT:"

CO~IPL" =D "~

'HL:->HOi:-

50-315 S-4-BO

~B. ~t 0 ~

5, 6.

I ~

02:-RA:T~4G S iAiM D.

C.

Cook Unct i fores Unit i fan"'eporting P-":odt The..al?o (I) IYt)t Naaet)late Mg (Gsoss I')DYe)t Design Bead R" ing (Net sbIYr'e)t maxim~ D MeM C='c-"e Phs UM'Ne)i:

IfCrw"es Ocar in Cape:.(.'ht y (Item (ticker Ju1 3250 1054 1080 S Thou~> I) Siac" Last Repor.. Give Rwonst

'" - "-9'.-Paore~vel'opi

'z R<<s

'~,If Any (';iet ADYe):

IO; R~wa'."m ~chas, IfAny:

This it)oath Yr.wo-Dat=.

Ci)~L.tive.

'1; Ho ~I.". Rt~r)A-.iag P.":od IZ. ife"..o~~ Qf'EoGeRe"ctor Yf~w.C;:W I~.; Re au~~~4ha<ovvn Ho'-'a I.'oa~am~~iMe tR U."it5~~hatdo~ Hots

'M: Gross It)'~tR.".=~y Cene.=td PI%)

'7. Gros cia'Wm~e~ Gcaewt~ ('I)YH) te. 4a'et~aJ =".=~ Geant~

( I'IYc-.)

-'l9-. Unirlerrt""ra):tor--

t)-.'ai~~'IaalL~L "cror

~Ua~aae~sar(Usia MDC Her)

~ UriMztadg&~tor(Using DeR 4c:)

~ Uni&n-Coat:e Rat

'4. Shatdo~xsSchedaied Over icxt 6."Ioa'.hs 0

3 207.9 0

0 0

0 0

10,118,931 3 245 802

62. 6

.6 60.

'0.3

11. 6

{Type. Date. aa Datcuon of E"ch)t 463 99 185 236 31 24 1

75. 4
75. 4
61. 8 7.3 t)~~L c.ad Of R" ort Pe:iod..Btiracted Date oi Stamp S. Units la Test Sea)as IP.":or to Ce......e~il Ope-.tioa):

A Foist Ac.'".ieved IliITIS,LCa.ii)C,'ITT INTIAL "=LeCTR!CITY 8 0 08>.80550't)s',,

)

AVERAGE DAILY UNIT POWER LEVEL DOCKET"NO.'ATE 8-1-80 COMPLETED BY W. T.

Gillett TELEPHONE 616-465-5901 MONTH Jul DAY AVERAGE DAILY POWER LEVEL (MWE-Net) 5 10 12 13

-15 DAY AVERAGE DAILY POWER LEVEL (MWe-Net) 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 INSTRUCTIONS On this'format list the average daily unit power level in MWe-Net for each day in the reporting month.

Compute to the nearest whole megawatt.

UNITSIIUTDOlUNS AND PO)UER REDUCTIONS

~J1 1999 DOCKET NO.'rVZmtmn TEI.EPilONE 616 465-5901 9 C

~

No.

l)ate 99) 9 CS L

r) 499 o

9

>)

~

91)

~ C/l g Llccnscc Event Rcpl>rt Jr c~

o 9))

Q D C ~

0 Cause & (.orrc<<tlvc Action tl>

Prcvcnt Rccurrcncc 160 800530 S

744 BII)C N.A.

ZZ ZZZZZZ The Unit was removed from service for Cycle IV - V refueling outage at 2228 hours0.0258 days <br />0.619 hours <br />0.00368 weeks <br />8.47754e-4 months <br /> EDT on 800530.

The Unit remained out of service the entire month.

~,

I': For<<cd S: Sched>>lcd

())/77)

Rc Json:

A-f<luipnlcnt Faihlrc (Explain)

II-hlaitttcrtance nr Test C-Rcfuclin(9 D-RCI,tllatory Restri<<lion E-Operator Train(I>I, &. Llccnsc Exanlhlation F-Administ rat ivc G.Operational Lrn>r (Iixplaitt)

I I Other (Explahl) hlethod:

I -Manual 2.Manual Scfanl.

3-Autolnatic Scram.

4-Other (Explain) 4 Exhibit G - Instructions I'or Prcparathn> oi Data Lorry Shccts for Li<<ctlsec Event Rcport (LI!R)File (NURI.'G-016I )

'LXhibit I - Salne Soul<<e

UNITSHUTDOWNS AND POWER REDUC i ONS INSTRUCTIONS This report should describe all plant shutdowns during the report period.

In addition. it should be the source of explan-ation of significant dips in average power levels.

Each signi ~

ficant reduction in power level (greater than 207'eduction in average daily power level for the preceding 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />) should be noted, even though the unit may not have been shut down cornpletelyl.

For such reductions in power level, the duration should be listed as zero, the method of reduction should be listed as 4 (Other), and the Cause and Corrective Action to Prevent Recurrence column should explain.

The Cause and Corrective Action to Prevent Recurrence column should be used to provide any needed explanation to fully describe the circumstances of the outage or power reduction.

NUMBER.

This column should indicate the sequential num-ber assigned to each shutdown or significant reduction in power for that calendar year.

When a shutdown or significant power reduction begins in one report period and ends in another, an entry should be made for both report periods to be sure all shutdowns or significant power reductions are reported.

Until a unit has achieved its first power generation, no num-ber should be assigned to each entry.

DATE.

This column should indicate the date of the start of each shutdown or signiiicant power reduction.

Report as year. month, and day.

August i4. 1977 would be reported as 770814.

When a shutdown or significant power reduction begins in one report period and ends in another, an entry should be made for both report periods to be sure all shutdowns or signiticant power reductions are reported.

TYPE.

Use "F" or "S" to indicate either "Forced" or "Sche-duled," respectively, for each shutdown or significant power reduction.

Forced shutdowns include those required to be initiated by no later than the weekend following discovery of an off-normal condition.

It is recognized that some judg-ment is required in categorizing shutdowns in this way.

In

general, a forced shutdown is one that would not have been completed in the absence of the condition for which corrective action was taken.

DURATION.

Seifwxplanatoiy.

When a shutdown extends beyond the end of a report period, count only the time to the end oi the report period and pick up the ensuing down time in the folio'wing report periods.

Report duration of outages rounded to the nearest tenth ofan hour to facilitate summation.

The sum of the total outage hours plus the hours the genera-tor was on line should equal the gross hours in the reporting period.

REASON.

Categorize by letter designation in accordance with the table appearing Un the report t'orm. Ifcategory H must be used. supply briei'comments.

METHOD OF SHUTTINC DOWN THE REACTOR OR REDUCING POWER.

Categt>rize by number designation INoie that this differs i'rom the Edison'Electric Institute (EEI) definitions of -Forced Partial Outage" and

-Sche-duled Partial Outage."

F>>r these tLrnis. I:Fl uses a change of

..0 NIW as the break pL>int.

FL>r larger pL>>ver reactors. 30 MW is u>>> small a change t>> warrant cxpianatiL>>i.

in accordance with the table appearing on the report torm.

Ifcategory 4 must be used, supply brief comments.

LICENSEE EVENT REPORT

='.

Reference the applicable reportable occurrence pertaining to the outage or power reduction.

Enter the first four parts (event year. sequential report number, occurrence code and report type) of the five part designation as described in Item 17 of Instructions for Preparation of Data Entry Sheets for Licensee Event Report (LER) File (NUREG416l).

This information may not be immediately evident for all such shutdowns, of course, since further investigation may be required to ascertain whether or not a reportable occurrence was involved.) Ifthe outage or power reduction will not result in a reportable occurrence.

the positive indication of this lack of correlation should be noted as not applicable (N/A).

SYSTEM CODE.

The system in which the outage or power reduction originated should be noted by the two digit code of Exhibit G - Instructions for Preparation of Data Entry Sheets for Licensee Event Report (LER) File (NUREG416I).

Systems that do not fit any existing code should be designa-ted XX. The code ZZ should be used for those events where a system is not applicable.

CO>>IPONENT CODE.

Select the most appropriate component from Exhibit I - Instructions for Preparation of Data Entry Sheets for Licensee Event Report (LER) File (NUREG416I).

using the followingcritieria:

A. Ifa component failed,use the component directly involved B.

If not a component failure, use the related component:

e.g.> wrong valve operated through error: list valve as "component.

C.

If a chain of failures occurs, the first component to mal-function should be listed. The sequence of events. includ-ing the other components which fail, should be described under the Cause and Corrective Action to Prevent Recur-rence column.

Components that do not fit any existing code should be de.

,signated XXXXXX. The code. ZZZZZZ should. be used

.'or events where a

component designation is not applicable.

CAUSE Sc CORRECTIVE ACTION TO PREVENT"RECUR-RENCE.

Use the column in a narrative fashion to ampiify or explain the circumstances of the shutdown or power reduction.

The column should include the soecific cause for each shut ~

down or significant power reduction and the immediate and contemplated long term corrective action taken. ifappropri-ate.

This column should also be used for a description of the major safety. related corrective maintenance performed during the outage or power reduction including an identification of the critical path activity and a report of any single release of radioactivity L>r single radiation exposure speciiically associ

~

ated with the outage which accounts for more than 10 percent oi the allowable annual values.

For long textual reports continue narrative on separate naper and reference tlie shutdown or power reduction for tins llarfa tive.

(L)/7 I

cket No.:

Unit Name:

Completed By:

Telephone:

Date:

Page:

50-315

,D.,C.

Cook Unit 81 R,.S.

Lease (616) 465-5901 August 7, 1980 lof 1 MONTHLY OPERATING ACTIVITIES -- JULY, 1980 Hi hli hts The Unit has been shut down the entire reporting period for its fourth Refueling Outage.

The time of shut down was 2228 hours0.0258 days <br />0.619 hours <br />0.00368 weeks <br />8.47754e-4 months <br /> 5/30/80.

Electrical generation for the month was 0.

Summary 7/2/80

-- Reactor Head was set on the vessel at 0530 hours0.00613 days <br />0.147 hours <br />8.763227e-4 weeks <br />2.01665e-4 months <br />.

7/9/80

-- The Reactor Plant entered Mode 5 with the initial bolting of the reactor head.

7/20/80 -- Safety Train "A" blackout testing was successfully completed.

7/21/80 -- Safety Train "B" blackout testing was successfully completed.

7/23/80 Filling and venting of the Reactor Coolant System, from the

~~ loop level was initiated at 1812 hours0.021 days <br />0.503 hours <br />0.003 weeks <br />6.89466e-4 months <br />.

7/26/80 7/27/80--

A steam bubble was formed in the Pressurizer at 0310 hours0.00359 days <br />0.0861 hours <br />5.125661e-4 weeks <br />1.17955e-4 months <br />.

System pressure was increased to 325 psig for hand rotation of the four Reactor Coolant Pumps.

The 0'14 pump would not rotate when the maximum recommended manual force was applied.

Reactor Coolant System pressure was reduced to 0 and the system drained to the 4 loop level by 0830 hours0.00961 days <br />0.231 hours <br />0.00137 weeks <br />3.15815e-4 months <br />.

This was to allow inspection of the thrust bearing of the 5'14 Reactor Coolant Pump.

7/30/80 Filling and venting of the Reactor Coolant System was initiated at 0048 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> and completed at 1928 hours0.0223 days <br />0.536 hours <br />0.00319 weeks <br />7.33604e-4 months <br /> 3/31/80.

~

~

'e f

DOCKET NO.

UNIT NAME DATE COMPLETED BY TELEPHONE PAGE 50 - 315 D.

C.

Cook - Unit No.

1 8-6-80 B. A. Svensson 616 465-5901 1 of 1

MAJOR SAFETY-RELATED MAINTENANCE JULY, 1980, M-1 The stem on DG-227C,'1CD diesel jacket water sample valve was broken with the valve open.

The valve was replaced.

NSW-244-3, non-essential service water containment isolation check valve failed Type C leak test.

Seat and disc were lapped and valve reassembled.

NSW-415-2, non-essential service water containment isolation check yylye failed Type C leak test.

Yalye body cleaned and new disc in-stalled.

M-4 M-6 M-8 No.

1 steam generator blowdown regulating valve, DRV-311, had a body to bonnet leak.

Disassembled valve, repaired steam cuts and re-assembled with new gaskets.

Had valve tested.

The reciprocating charging pump discharge valve, CS-386, was leaking by.

Disassembled valve and lapped seat.

Reassembled with a new stem and plug.

The sample pump for radiation monitors R-11 and R-12 would not run.

Replaced the pump and had it tested.

The motor driven auxiliary feedpump was inspected to check condition

,of the outboard pump bearing.

Replaced the rotating assembly and tested the pump.

The west centrifugal charging pump had a broken shaft.

Replaced the rotating assembly and retested the pump.

Safety injection check valves on the lines to the reactor coolant hot legs of all four loops, SI-158Ll, L2, L3 and L4 had body to bonnet leaks.

Replaced bonnet gaskets in all four valves.

e

~

~ 'A t

e t