Forwards Info Re Qualification Pressure for safety-related Equipment in Drywell.Drywell Pressure of 0.7 Psia Calculated & Will Be Used to Qualify All safety-related Equipment in Drywell Required During & After LOCA
ML17317B544
Person / Time
Site: 05000447, 05000531, 05000550
Issue date: 10/11/1978
From: Sherwood G
GENERAL ELECTRIC CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
MFN-385-78, NUDOCS 7810180108
Download: ML17317B544 (2)


Text

NRC FORM 366 7

U. S. NUCLEAR REGULATORYCOMMISSION LICENSEE EVENT REPORT CONTROL BLOCK:

Q1 (PLEASE PRINT OR TYPE ALLREQUIRED INFORMATION)

"1 6

~97 M

1 0

C C

1 Q2 0

0 0

0 0

0 0

0 0

0 0 Q24 1

1 1

1 QR~Qs 7

8 9

LICENSEE CODE 14 15 LICENSE NUMBER 25 26 LICENSE TYPE 30 57 CAT 58 CON'T soo'RR,~LQR 0

5 0

0 0

3 1

8 Q70 8'.2, 8

7 8

Qs 0

9 2

7 7

8 Qe 7

8 60 61 DOCKET NUMBER 68 69 EVENT DATE 74 75 REPORT DATE EVENT DESCRIPTION AND PROBABLE CONSEQUENCES Q10

~o2 ON 8-28-78 DURING A RAPID LOAD REDUCTION FROM 100Ã to 805 THE AXIAL FLUX DIFFERENCE WENT OUTSIDE THE TARGET BAND.

THE AXIAL FLUX DIFFERENCE WAS RESTORED TO WITHIN THE

~p4

'ARGET BAND IN 12 MINUTES IN COMPLIANCE WITH THE 15 MINUTE ACTION RE UIREMENT OF 6

T.

S ~

3 ~ 2 ~ 1

~

SINCE THE TIME OUTSIDE eTHE TARGET BAND WAS LIMITED, PEAKING FACTORS WERE NOT SUFFICIENTLY ALTERED BY XENON REDISTRIBUTION UPON THE SUBSEQUENT RETURN TO RATED THERMAL POWER TO CAUSE ANY PROBABLE ADVERSE CONSEQUENCES' B

SIMILAR OCCURRENCE; 050-.315 78-.013 80 7

8 9

~OB SYSTEM CAUSE CAUSE COMP.

VALVE.

,CODE CODE SUBCODE COMPONENT CODE SUBCODE SUBCODE

~ZZ Qll X

Q72

~ZQ72 Z

Z Z

Z Z

Z Q14

~ZQls

~Z:

Qls 7

8 9

10 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISION LF RIRO EVENTYEAR REPORT NO.

CODE TYPE NO.

Q17 flsPORT

~78

~

~08 I

Q~

~03 QL LJ LOJ 21 22 23 24 26 27 28 29 30 31 32 ACTION FUTURE EFFECT SHUTDOWN ATTACHMENT NPRDC PRIME COMP.

COMPONENT TAKEN ACTION ON PLANT METHOD HOURS Q22 SUBMITTED FORM SUB.

SUPPLIER MANUFACTURER

[ ZJQls ~ZQ19

~ZQ29 LZJQ>>

O O

O O

N Q22

~SQ24

~ZQ25 Z

9 9

9 Q29 33 34 35 36 37 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS Q27 o

REPAIRS TO TWO S

E R

.AIR EJECTORS AS B TH V E

PREVENT. A LOH'ACUUM TRIP UNTIL THE STEAM WAS RESTORED.

AT TH T 3

HERE BORATED OUT TO RESTORE THE'XIAL FLUX TO WITHIN THE TARGET BAND AND POWER W

RETURNED TO 100K.

7 8

9 FACILITY

~3P METHOD OF STATUS 98 POWER OTHERSTATUS ~

DISCOVERY s

~FQ29 ~l0 0

Qe NA

~AQ27 7

8 9

10 12 13 44 45 46 ACTIVITY CONTENT RELEASED OF RELEASE AMOUNTOF ACTIVITY~

G Z

Q33 ZQ34 7

8 9

10 44 45 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTION 7 ~00 0 Qsl Z

Qos NA 7

8 9

11 12 13 PERSONNEL INJURIES NUMBER DESCRIPTION 41 9 ~00 0

QRo 7

8 9

11 12 LOSS OF OR DAMAGETO FACILITYQ43 TYPE DESCRIPTION 9

Z Q42 NA 7

8 9

10 PUBLICITY 7

8 9

IO~

80 W

80 80 80 80 80 NRC USE ONLY cva 80 a 0

68 69 (616) 465-,5901 DISCOVERY DESCRIPTION Q32 OPERATOR OBSERVATION LOCATIONOF'ELEASE Q NA

PE 4