ML17313A761

From kanterella
Jump to navigation Jump to search
Forwards PVNGS Unit 3 Inservice Insp Rept Seventh Refueling Outage, Per 10CFR50.55a.Ltr Contains No New Commitments
ML17313A761
Person / Time
Site: Palo Verde Arizona Public Service icon.png
Issue date: 01/22/1999
From: Ide W
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17313A763 List:
References
102-04235-WEI-A, 102-4235-WEI-A, NUDOCS 9902020273
Download: ML17313A761 (4)


Text

CATEGORY 1 REGULATORY IPTFORMATION DISTRIBUTIO SYSTEM (RIDS)

ACCESSION NBR:9902020273 DOC.DATE: 99/01/22 NOTARIZED: NO DOCKET FACIL:STN<50-530 Palo Verde Nuclear Station, Unit 3, Arizona Publi 05000530 AUTH. NAME AUTHOR AFFILIATION IDE,W.E. Arizona Public Service Co. (formerly Arizona Nuclear Power RECIP.NAME RECIPIENT AFFILIATION Records Management Branch (Document Control Desk)

SUBJECT:

Forwards "PVNGS UNit 3 Inservice Insp Rept Seventh Refueling Outage," per 10CFR50.55a.Ltr contains no new commitments.

DISTRIBUTION CODE: A047D COPIES RECEIVED':LTR ENCL SIZE:

TITLE: OR Submittal: Inservice/Testing/Relief from ASME Code - GL-89 -04 NOTES:Standardized plant. 05000530 RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD4-2 LA 1 1 PD4-2 PD 1 1 FIELDS,M 1 1 INTERNAL: 1 1 AEOD/SPD/RAB 1 1 1 1 NRR/DE/ECGB 1 1 NRR/DE/EMEB 1 1 NUDOCS-ABSTRACT 1 1 OGC/HDS2 1 0 RES/DET/EIB 1 1 RES/DET/EMMEB 1 1 EXTERNAL: LITCO ANDERSON 1 1 NOAC NRC PDR 1 1 D

N NOTE TO ALL nRIDSn RECIPIENTS PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DZSTRIBUTZON LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD) ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED: LTTR 15 ENCL 14

1It,:0 i .

Comm//moot. tnoorotlmL &erg.

William E. Ide Mail Station 7605 Palo Verde Nuclear Vice President TEL 602/3934116 P.O. Box 52034 Generating Station Nuclear Englneedng FAX 602/3934077 Phoenix, AZ 85072-2034 102-04235-WEI/AKK/MLG January 22 1999 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Mail Station P1-37 Washington, DC 20555-0001

Dear Sirs:

Subject:

Palo Verde Nuclear Generating Station (PVNGS)

Unit 3 Docket No. STN 50-530 Unit 3 Inservice Inspection Report Seventh Refueling Outage Pursuant to 10CFR50.55a, enclosed please find the PVNGS Unit 3 Inservice Inspection Report for the seventh refueling outage.

No commitments are being made to the NRC by this letter.

If you have any questions, please contact Scott A. Bauer at (602) 393-5978.

Sincerely, WEI/AKK/MLG/rlh Enclosure cc: E. W. Merschoff O 008+

M. B. Fields J. H. Moorman 9902020273 9'ttOi22 05000530, Pt l

PDR ADQCK PDRjj

4 lM

<<'!